Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Phys Med Biol ; 56(1): 87-104, 2011 Jan 07.
Artigo em Inglês | MEDLINE | ID: mdl-21119230

RESUMO

Today, new single photon emission computed tomography (SPECT) reconstruction techniques rely on accurate Monte Carlo (MC) simulations to optimize reconstructed images. However, existing MC scintillation camera models which usually include an accurate description of the collimator and crystal, lack correct implementation of the gamma camera's back compartments. In the case of dual isotope simultaneous acquisition (DISA), where backscattered photons from the highest energy isotope are detected in the imaging energy window of the second isotope, this approximation may induce simulation errors. Here, we investigate the influence of backscatter compartment modelling on the simulation accuracy of high-energy isotopes. Three models of a scintillation camera were simulated: a simple model (SM), composed only of a collimator and a NaI(Tl) crystal; an intermediate model (IM), adding a simplified description of the backscatter compartments to the previous model and a complete model (CM), accurately simulating the materials and geometries of the camera. The camera models were evaluated with point sources ((67)Ga, (99m)Tc, (111)In, (123)I, (131)I and (18)F) in air without a collimator, in air with a collimator and in water with a collimator. In the latter case, sensitivities and point-spread functions (PSFs) simulated in the photopeak window with the IM and CM are close to the measured values (error below 10.5%). In the backscatter energy window, however, the IM and CM overestimate the FWHM of the detected PSF by 52% and 23%, respectively, while the SM underestimates it by 34%. The backscatter peak fluence is also overestimated by 20% and 10% with the IM and CM, respectively, whereas it is underestimated by 60% with the SM. The results show that an accurate description of the backscatter compartments is required for SPECT simulations of high-energy isotopes (above 300 keV) when the backscatter energy window is of interest.


Assuntos
Câmaras gama , Modelos Biológicos , Método de Monte Carlo , Radiometria/métodos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Simulação por Computador , Humanos , Radioisótopos , Reprodutibilidade dos Testes , Espalhamento de Radiação , Sensibilidade e Especificidade , Iodeto de Sódio/química , Tálio/química
2.
Phys Med Biol ; 49(19): 4543-61, 2004 Oct 07.
Artigo em Inglês | MEDLINE | ID: mdl-15552416

RESUMO

Monte Carlo simulation is an essential tool in emission tomography that can assist in the design of new medical imaging devices, the optimization of acquisition protocols and the development or assessment of image reconstruction algorithms and correction techniques. GATE, the Geant4 Application for Tomographic Emission, encapsulates the Geant4 libraries to achieve a modular, versatile, scripted simulation toolkit adapted to the field of nuclear medicine. In particular, GATE allows the description of time-dependent phenomena such as source or detector movement, and source decay kinetics. This feature makes it possible to simulate time curves under realistic acquisition conditions and to test dynamic reconstruction algorithms. This paper gives a detailed description of the design and development of GATE by the OpenGATE collaboration, whose continuing objective is to improve, document and validate GATE by simulating commercially available imaging systems for PET and SPECT. Large effort is also invested in the ability and the flexibility to model novel detection systems or systems still under design. A public release of GATE licensed under the GNU Lesser General Public License can be downloaded at http:/www-lphe.epfl.ch/GATE/. Two benchmarks developed for PET and SPECT to test the installation of GATE and to serve as a tutorial for the users are presented. Extensive validation of the GATE simulation platform has been started, comparing simulations and measurements on commercially available acquisition systems. References to those results are listed. The future prospects towards the gridification of GATE and its extension to other domains such as dosimetry are also discussed.


Assuntos
Simulação por Computador , Software , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Método de Monte Carlo , Reprodutibilidade dos Testes , Termodinâmica
3.
Phys Med Biol ; 49(2): 271-85, 2004 Jan 21.
Artigo em Inglês | MEDLINE | ID: mdl-15083671

RESUMO

Monte Carlo simulations are increasingly used in scintigraphic imaging to model imaging systems and to develop and assess tomographic reconstruction algorithms and correction methods for improved image quantitation. GATE (GEANT4 application for tomographic emission) is a new Monte Carlo simulation platform based on GEANT4 dedicated to nuclear imaging applications. This paper describes the GATE simulation of a prototype of scintillation camera dedicated to small-animal imaging and consisting of a CsI(Tl) crystal array coupled to a position-sensitive photomultiplier tube. The relevance of GATE to model the camera prototype was assessed by comparing simulated 99mTc point spread functions, energy spectra, sensitivities, scatter fractions and image of a capillary phantom with the corresponding experimental measurements. Results showed an excellent agreement between simulated and experimental data: experimental spatial resolutions were predicted with an error less than 100 microns. The difference between experimental and simulated system sensitivities for different source-to-collimator distances was within 2%. Simulated and experimental scatter fractions in a [98-182 keV] energy window differed by less than 2% for sources located in water. Simulated and experimental energy spectra agreed very well between 40 and 180 keV. These results demonstrate the ability and flexibility of GATE for simulating original detector designs. The main weakness of GATE concerns the long computation time it requires: this issue is currently under investigation by the GEANT4 and the GATE collaborations.


Assuntos
Câmaras gama , Animais , Simulação por Computador , Processamento de Imagem Assistida por Computador , Método de Monte Carlo , Distribuição Normal , Imagens de Fantasmas , Espalhamento de Radiação , Sensibilidade e Especificidade , Software
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA