Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
PLoS One ; 19(2): e0297314, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38330070

RESUMO

Cardiac MRI is a crucial tool for assessing congenital heart disease (CHD). However, its application remains challenging in young children when performed at 3T. The aim of this retrospective single center study was to compare a non-contrast free-breathing 2D CINE T1-weighted TFE-sequence with compressed sensing (FB 2D CINE CS T1-TFE) with 3D imaging for diagnostic accuracy of CHD, image quality, and vessel diameter measurements in sedated young children. FB 2D CINE CS T1-TFE was compared with a 3D non-contrast whole-heart sequence (3D WH) and 3D contrast-enhanced MR angiography (3D CE-MRA) at 3T in 37 CHD patients (20♂, 1.5±1.4 years). Two radiologists independently assessed image quality, type of CHD, and diagnostic confidence. Diameters and measures of contrast and sharpness of the aorta and pulmonary vessels were determined. A non-parametric multi-factorial approach was used to estimate diagnostic accuracy for the diagnosis of CHD. Linear mixed models were calculated to compare contrast and vessel sharpness. Krippendorff's alpha was determined to quantify vessel diameter agreement. FB 2D CINE CS T1-TFE was rated superior regarding image quality, diagnostic confidence, and diagnostic sensitivity for both intra- and extracardiac pathologies compared to 3D WH and 3D CE-MRA (all p<0.05). FB 2D CINE CS T1-TFE showed superior contrast and vessel sharpness (p<0.001) resulting in the highest proportion of measurable vessels (740/740; 100%), compared to 3D WH (530/620; 85.5%) and 3D CE-MRA (540/560; 96.4%). Regarding vessel diameter measurements, FB 2D CINE CS T1-TFE revealed the closest inter-reader agreement (Krippendorff's alpha: 0.94-0.96; 3D WH: 0.78-0.94; 3D CE-MRA: 0.76-0.93). FB 2D CINE CS T1-TFE demonstrates robustness at 3T and delivers high-quality diagnostic results to assess CHD in sedated young children. Its ability to function without contrast injection and respiratory compensation enhances ease of use and could encourage widespread adoption in clinical practice.


Assuntos
Meios de Contraste , Cardiopatias Congênitas , Criança , Humanos , Pré-Escolar , Estudos Retrospectivos , Imageamento Tridimensional/métodos , Cardiopatias Congênitas/diagnóstico por imagem , Imageamento por Ressonância Magnética , Angiografia por Ressonância Magnética/métodos , Reprodutibilidade dos Testes
2.
HPB (Oxford) ; 26(1): 91-101, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37806830

RESUMO

BACKGROUND: As prevention of posthepatectomy-liver-failure is crucial, there is need of dynamic assessment of liver function, even intraoperatively. 13C-methacetin-breath-test estimates the organ's microsomal functional capacity. This is its first intraoperative evaluation in major liver surgery. METHODS: 30 patients planed for resection of ≥3 liver segments, between March-November 2019, were prospectively enrolled in this "single-center", pilot study. Using the 13C-methacetin-breath-test, liver function was assessed four times: preoperatively, intraoperatively before and after resection and postoperatively. The resulted maximum-liver-function-capacity (LiMAx)-values and delta-over-baseline (DOB)-curves were compared, further analyzed and correlated to respective liver volumes. RESULTS: The intraoperative LiMAx-values before resection were mostly lower than the preoperative ones (-11.3% ± 28%). The intraoperative measurements after resection resulted to mostly higher values than the postoperative ones (42.35% ± 46.19%). Pharmacokinetically, an interference between the two intraoperative tests was observed. There was no strong correlation between residual liver volume and function with a percentual residual-LiMAx mostly lower than the percentual residual volume (-17.7% ± 4.1%). CONCLUSIONS: Intraoperative application of the 13C-methacetin-breath-test during major liver resections seems to deliver lower values than the standard preoperative test. As multiple intraoperative tests interfere significantly to each other, a single intraoperative measurement is suggested. Multicentric standardized measurements could define the "normal" range for intraoperative measurements and control their predictive value.


Assuntos
Hepatectomia , Fígado , Humanos , Projetos Piloto , Testes de Função Hepática , Fígado/cirurgia , Hepatectomia/efeitos adversos , Testes Respiratórios/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA