Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Animals (Basel) ; 13(16)2023 Aug 09.
Artigo em Inglês | MEDLINE | ID: mdl-37627363

RESUMO

The objective of the present study was to investigate the residue depletion of EF and CF in yellow catfish to estimate its WTs in plasma and tissues after multiple oral doses for 3 days at 20 mg/kg at 15, 20, and 25 °C. Samples were collected at pre-designed time points after oral doses. A validated method was performed to quantify EF and CF in plasma and tissues by high-performance liquid chromatography. Statistical differences were conducted using one-way ANOVA analysis. According to the maximum residue limit of China and Europe considering 95% percentile with 95% confidence, the WTs were estimated to be 44, 72, 66, 99, and 95 days at 15 °C; 32, 66, 65, 86, and 73 days at 20 °C; and 32, 61, 64, 55, and 59 days at 25 °C in the plasma, muscle and skin, gill, liver, and kidney, respectively. We found that increased temperature shortened the WTs in plasma and tissues. Therefore, this study can help the risk assessment of EF in aquatic products for human health at different temperatures to avoid residue violation.

2.
Food Res Int ; 166: 112604, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36914350

RESUMO

Doxycycline is an important medicine in aquaculture for treating fish diseases. However, its excess use causes residue exceeding to threaten human health. So, this study aimed to estimate a reliable withdrawal time (WT) of doxycycline (DC) in crayfish (Procambarus clarkii) based on statistical approaches and conduct a risk assessment for human health in the natural environment. Samples were collected at predetermined time points and determined by high-performance liquid chromatography. A novel statistical method was used to process the data of residue concentration. The homogeneity and linearity of the regressed line of data were evaluated by Bartlett's, Cochran's, and F tests. Outliers were excluded by establishing the standardized residual versus their cumulative frequency distribution on a normal probability scale. The calculated WT was 43 days in muscle of crayfish based on China and European stipulations. After 43 days, estimated daily intakes of DC were ranged from 0.022 to 0.052 µg/kg/d. Hazard Quotients were ranged from 0.007 to 0.014, which were far less than 1. These results indicated that established WT could avoid health risks for humans resulting from DC's residue in crayfish.


Assuntos
Astacoidea , Doxiciclina , Animais , Humanos , Astacoidea/química , Alimentos Marinhos/análise , Meio Ambiente , Medição de Risco
3.
Front Oncol ; 12: 918296, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36267985

RESUMO

Background: The setup accuracy plays an extremely important role in the local control of tumors. The purpose of this study is to verify the feasibility of "Sphere-Mask" Optical Positioning System (S-M_OPS) for fast and accurate setup. Methods: From 2016 to 2021, we used S-M_OPS to supervise 15441 fractions in 1981patients (with the cancer in intracalvarium, nasopharynx, esophagus, lung, liver, abdomen or cervix) undergoing intensity-modulated radiation therapy (IMRT), and recorded the data such as registration time and mask deformation. Then, we used S-M_OPS, laser line and cone beam computed tomography (CBCT) for co-setup in 277 fractions, and recorded laser line-guided setup errors and S-M_OPS-guided setup errors with CBCT-guided setup result as the standard. Results: S-M_OPS supervision results: The average time for laser line-guided setup was 31.75s. 12.8% of the reference points had an average deviation of more than 2 mm and 5.2% of the reference points had an average deviation of more than 3 mm. Co-setup results: The average time for S-M_OPS-guided setup was 7.47s, and average time for CBCT-guided setup was 228.84s (including time for CBCT scan and manual verification). In the LAT (left/right), VRT (superior/inferior) and LNG (anterior/posterior) directions, laser line-guided setup errors (mean±SD) were -0.21±3.13mm, 1.02±2.76mm and 2.22±4.26mm respectively; the 95% confidence intervals (95% CIs) of laser line-guided setup errors were -6.35 to 5.93mm, -4.39 to 6.43mm and -6.14 to 10.58mm respectively; S-M_OPS-guided setup errors were 0.12±1.91mm, 1.02±1.81mm and -0.10±2.25mm respectively; the 95% CIs of S-M_OPS-guided setup errors were -3.86 to 3.62mm, -2.53 to 4.57mm and -4.51 to 4.31mm respectively. Conclusion: S-M_OPS can greatly improve setup accuracy and stability compared with laser line-guided setup. Furthermore, S-M_OPS can provide comparable setup accuracy to CBCT in less setup time.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA