Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Jpn J Radiol ; 41(5): 510-520, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36538163

RESUMO

PURPOSE: We have developed an in-house software equipped with partial image phase-only correlation (PIPOC) which can automatically quantify radiographic joint space narrowing (JSN) progression. The purpose of this study was to evaluate the software in phantom and clinical assessments. MATERIALS AND METHODS: In the phantom assessment, the software's performance on radiographic images was compared to the joint space width (JSW) difference using a micrometer as ground truth. A phantom simulating a finger joint was scanned underwater. In the clinical assessment, 15 RA patients were included. The software measured the radiological progression of the finger joints between baseline and the 52nd week. The cases were also evaluated with the Genant-modified Sharp score (GSS), a conventional visual scoring method. We also quantitatively assessed these joints' synovial vascularity (SV) on power Doppler ultrasonography (0, 8, 20 and 52 weeks). RESULTS: In the phantom assessment, the PIPOC software could detect changes in JSN with a smallest detectable difference of 0.044 mm at 0.1 mm intervals. In the clinical assessment, the JSW change of the joints with GSS progression detected by the software was significantly greater than those without GSS progression (p = 0.004). The JSW change of joints with positive SV at baseline was significantly higher than those with negative SV (p = 0.024). CONCLUSION: Our in-house software equipped with PIPOC can automatically and quantitatively detect slight radiographic changes of JSW in clinically inactive RA patients.


Assuntos
Artrite Reumatoide , Humanos , Artrite Reumatoide/diagnóstico por imagem , Radiografia , Articulações dos Dedos/diagnóstico por imagem , Software , Ultrassonografia , Progressão da Doença
2.
Jpn J Radiol ; 38(10): 979-986, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32488501

RESUMO

PURPOSE: Rheumatoid arthritis (RA) causes joint space narrowing (JSN) as a form of joint destruction. We developed an automatic system that can detect joint locations and compute the joint space difference index (JSDI), which was defined as the chronological change in JSN between two radiographs. This study aims to evaluate the application of "machine vision" for radiographic image of the finger joints. MATERIALS AND METHODS: Fifteen RA patients with long-term sustained clinical low disease activity were recruited. All patients underwent hand radiography and power Doppler ultrasonography (PDUS). The JSN was evaluated using the Genant-modified Sharp scoring (GSS) method and the automatic system. Synovial vascularity (SV) was assessed quantitatively using ultrasonography. RESULTS: There were no significant differences in the JSDI between the joints with JSN and those without JSN on GSS (p = 0.052). The JSDI of the joints with SV was significantly higher than those without SV (p = 0.043). The JSDI of the no therapeutic response group was significantly higher than those of the response group (p < 0.001). CONCLUSION: Our software can automatically evaluate temporal changes of JSN, which might free rheumatologists / radiologists from the burden of scoring hand radiography.


Assuntos
Artrite Reumatoide/diagnóstico por imagem , Articulações dos Dedos/diagnóstico por imagem , Processamento de Imagem Assistida por Computador , Radiografia , Software , Adulto , Idoso , Progressão da Doença , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Ultrassonografia Doppler
3.
Rheumatol Int ; 39(8): 1413-1421, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31089859

RESUMO

Ultrasonography is useful for assessment of synovitis in the hand of rheumatoid arthritis (RA) patients. The aim of this study was to investigate the predictive value of the quantitative power Doppler (PD) signal assessment in the subchondral bone region of the metacarpophalangeal (MCP) joint in patients with RA showing radiographic progression of the hand by comparing with those of previously reported scoring systems. Twenty-two patients (20 women) with RA who underwent power Doppler ultrasonography (PDUS) of the bilateral one to five MCP joints at baseline were included in the study. Radiography of both hands was performed at baseline and at 1 year. PDUS of the synovial space was evaluated according to semi-quantitative scoring (0-3) and quantitative measurement (0-100%). The PD signal in the subchondral bone region was qualitatively (0, 1) and quantitatively (mm2) assessed. The performance of PDUS assessment was compared using the area under the curve (AUC) of the receiver operating characteristic (ROC) curve and the risk ratio (RR). As a predictor for radiographic progression, the quantitative PD signal assessment in the subchondral bone region (AUC = 0.842, p < 0.01) was equivalent to quantitative vascularity (AUC = 0.817, p < 0.05) and semi-quantitative scoring (AUC = 0.754, p < 0.05). As for the RR of the PD signal in the subchondral bone region for radiographic progression, the quantitative PD signal assessment was 5.40 (p < 0.01), whereas the qualitative PD signal assessment was 1.60 (p = 0.204). Quantitative PD signal assessment in the subchondral bone region can predict radiographic progression in the hand of RA patients.


Assuntos
Artrite Reumatoide/diagnóstico por imagem , Articulação Metacarpofalângica/diagnóstico por imagem , Sinovite/diagnóstico por imagem , Ultrassonografia Doppler , Adulto , Idoso , Antirreumáticos/uso terapêutico , Artrite Reumatoide/tratamento farmacológico , Progressão da Doença , Feminino , Humanos , Masculino , Articulação Metacarpofalângica/efeitos dos fármacos , Pessoa de Meia-Idade , Variações Dependentes do Observador , Projetos Piloto , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estudos Retrospectivos , Índice de Gravidade de Doença , Sinovite/tratamento farmacológico , Fatores de Tempo
4.
Br J Radiol ; 91(1086): 20170748, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29565675

RESUMO

OBJECTIVE: Power Doppler ultrasonography (PDUS) and MRI are independently useful to predict structural damage in patients with rheumatoid arthritis (RA). We hypothesize that there is a complementary relationship between these modalities. The aim of this study is, therefore, to investigate the usefulness of the predictive value of composite assessment of PDUS and contrast-enhanced MRI in radiographic outcomes in patients with RA. METHODS: 20 patients (17 females and 3 males) with RA on disease-modifying antirheumatic drugs underwent PDUS and MRI of both hands at baseline. Radiography of the bilateral hands was performed at baseline and at 1 year. Articular synovitis on PDUS was evaluated according to quantitative measurement. Synovitis, bone marrow edema and bone erosion were scored according to the RA MRI scoring method. The changes of joint space narrowing and bone erosion on radiograph were assessed by the Sharp/van der Heijde method. We applied t-statistics to combine the assessment of quantitative PDUS with semiquantitative MRI. RESULTS: Structural damage progression for radiography was not correlated with any evaluations for MRI, while it showed significant correlation with synovitis on PDUS (rs = 0.597, p = 0.005). The composite assessment of both modalities (synovitis for PDUS and bone marrow edema for MRI) was correlated with structural damage progression on radiograph (rs = 0.792, p < 0.0001). CONCLUSION: Composite assessment of PDUS and MRI may have a stronger predictive value in radiographic progression than PDUS or MRI alone in RA. Advances in knowledge: Composite assessment of PDUS and MRI may be an effective predictor of structural damage in RA.


Assuntos
Artrite Reumatoide/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Ultrassonografia Doppler/métodos , Adulto , Idoso , Artrite Reumatoide/patologia , Progressão da Doença , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Radiografia
5.
Br J Radiol ; 89(1061): 20151000, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26942294

RESUMO

OBJECTIVE: To improve on the reproducibility and sensitivity of the assessment of patients with rheumatoid arthritis (RA), two semi-automated measurement methods of the area of enhancing pannus (AEP), based on thresholding (AEP_THRES) and pixel-by-pixel time-intensity curve analysis (AEP_TIC), were evaluated as an alternative for the gold-standard manual contouring method (AEP_MANUAL). METHODS: 8 patients (7 females and 1 male) with RA of the wrist or finger joints participated in the study. A three-dimensional contrast-enhanced dynamic sequence was used at 3 T. After identifying the most relevant time-intensity curve (TIC) shape in terms of synovitis by comparing with the synovitis score using the RA-MRI scoring system, three different approaches for measuring the AEP were performed. Spearman's test of rank correlation was used to compare AEPs via two semi-automated methods (AEP_THRES and AEP_TIC) against manual segmentation (AEP_MANUAL) in the entire hand region as well as the wrist and the finger regions. RESULTS: The TIC shape of "washout after fast initial enhancement" had excellent correlation with synovitis score (r = 0.809). The correlation coefficient between AEP_TIC and AEP_MANUAL was evaluated to be better than that of AEP_THRES and AEP_MANUAL in the wrist region (AEP_THRES: r = 0.716, AEP_TIC: r = 0.815), whereas these were of comparable accuracy for the entire hand and the finger regions. CONCLUSION: This study suggests that TIC analysis may be an alternative to manual contouring for pannus quantification and provides important clinical information of the extent of the disease in patients with RA. ADVANCES IN KNOWLEDGE: TIC shape analysis can be applied for new quantitative assessment for RA synovitis in the wrist.


Assuntos
Artrite Reumatoide/patologia , Interpretação de Imagem Assistida por Computador/métodos , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética , Sinovite/patologia , Adulto , Idoso , Artrite Reumatoide/complicações , Meios de Contraste , Feminino , Dedos/patologia , Mãos/patologia , Humanos , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sinovite/complicações , Articulação do Punho/patologia
7.
Med Phys ; 39(9): 5584-91, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22957624

RESUMO

PURPOSE: In accurate proton spot-scanning therapy, continuous target tracking by fluoroscopic x ray during irradiation is beneficial not only for respiratory moving tumors of lung and liver but also for relatively stationary tumors of prostate. Implanted gold markers have been used with great effect for positioning the target volume by a fluoroscopy, especially for the cases of liver and prostate with the targets surrounded by water-equivalent tissues. However, recent studies have revealed that gold markers can cause a significant underdose in proton therapy. This paper focuses on prostate cancer and explores the possibility that multiple-field irradiation improves the underdose effect by markers on tumor-control probability (TCP). METHODS: A Monte Carlo simulation was performed to evaluate the dose distortion effect. A spherical gold marker was placed at several characteristic points in a water phantom. The markers were with two different diameters of 2 and 1.5 mm, both visible on fluoroscopy. Three beam arrangements of single-field uniform dose (SFUD) were examined: one lateral field, two opposite lateral fields, and three fields (two opposite lateral fields + anterior field). The relative biological effectiveness (RBE) was set to 1.1 and a dose of 74 Gy (RBE) was delivered to the target of a typical prostate size in 37 fractions. The ratios of TCP to that without the marker (TCP(r)) were compared with the parameters of the marker sizes, number of fields, and marker positions. To take into account the dependence of biological parameters in TCP model, α∕ß values of 1.5, 3, and 10 Gy (RBE) were considered. RESULTS: It was found that the marker of 1.5 mm diameter does not affect the TCPs with all α∕ß values when two or more fields are used. On the other hand, if the marker diameter is 2 mm, more than two irradiation fields are required to suppress the decrease in TCP from TCP(r) by less than 3%. This is especially true when multiple (two or three) markers are used for alignment of a patient. CONCLUSIONS: It is recommended that 1.5-mm markers be used to avoid the reduction of TCP as well as to spare the surrounding critical organs, as long as the markers are visible on x-ray fluoroscopy. When 2-mm markers are implanted, more than two fields should be used and the markers should not be placed close to the distal edge of any of the beams.


Assuntos
Marcadores Fiduciais , Método de Monte Carlo , Terapia com Prótons , Doses de Radiação , Radioterapia/normas , Humanos , Masculino , Probabilidade , Neoplasias da Próstata/radioterapia , Dosagem Radioterapêutica
8.
Radiol Phys Technol ; 3(1): 16-22, 2010 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-20821097

RESUMO

The results of Monte Carlo calculated dose distributions of proton treatment of ocular melanoma are presented. An efficient spot scanning method utilizing active energy modulation, which also minimizes the number of target spots was developed. We simulated various parameter values for the particle energy spread and the pencil beam diameter in order to determine values suitable for medical treatment. We found that a 2.5-mm-diameter proton beam with a 5% Gaussian energy spread was suitable for treatment of ocular melanoma while preserving vision for the typical case that we simulated. The energy spectra and the required proton current were also calculated and are reported. The results are intended to serve as a guideline for a new class of low-cost, compact accelerators.


Assuntos
Neoplasias Oculares/radioterapia , Melanoma/radioterapia , Terapia com Prótons , Doses de Radiação , Neoplasias Oculares/patologia , Humanos , Lasers , Melanoma/patologia , Método de Monte Carlo , Órgãos em Risco/efeitos da radiação , Dosagem Radioterapêutica , Carga Tumoral
9.
Radiol Phys Technol ; 3(1): 84-92, 2010 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-20821107

RESUMO

In the physical processes of proton interaction in bio-materials, most of the proton energy is transferred to electrons. Ionization and excitation occur most frequently around the Bragg peak region, where nuclear reactions also exist. In this study, we investigated the processes of energy deposition by considering interactions including the nuclear reactions between protons and water molecules by a Monte Carlo simulation for proton therapy. We estimated the number of particles produced by a variety of nuclear reactions, and we focused on the interaction in the low-energy region (below 1 MeV). Furthermore, we considered the charge-changing processes in the low-energy region (less than a few hundred keV). Finally, we evaluated the total dose and the contribution of primary protons and secondary particles through nuclear reactions to the absorbed dose. The results showed that the protons generate numerous neutrons via nuclear reactions. Particularly, neutrons with relatively low energies produce recoil protons by elastic collisions with the hydrogen atoms. Around the Bragg peak, low-energy primary protons (slowed-down protons) are prevalent, whereas recoil (secondary) protons gradually become dominant behind the distal falloff region of the Bragg peak. Therefore, around the Bragg peak, the main contribution to the absorbed dose is that of the primary protons (from 80 to 90%), whereas secondary protons created by primary proton-induced reactions contribute to the dose from 20 to 5%. Behind the distal endpoint of the Bragg peak, the absorbed dose is mainly due to the protons produced by (1)H(n, p), and the contribution of these is about 70%.


Assuntos
Energia Nuclear , Terapia com Prótons , Método de Monte Carlo , Imagens de Fantasmas , Dosagem Radioterapêutica , Água
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA