Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Heart Rhythm ; 19(2): 295-305, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34662707

RESUMO

BACKGROUND: Ventricular fibrillation (VF) is characterized by multiple wavelets and rotors. No equation to predict the number of rotors and wavelets observed during fibrillation has been validated in human VF. OBJECTIVE: The purpose of this study was to test the hypothesis that a single equation derived from a Markov M/M/∞ birth-death process could predict the number of rotors and wavelets occurring in human clinical VF. METHODS: Epicardial induced VF (256-electrode) recordings obtained from patients undergoing cardiac surgery were studied (12 patients; 62 epochs). Rate constants for phase singularity (PS) (which occur at the pivot points of rotors) and wavefront (WF) formation and destruction were derived by fitting distributions to PS and WF interformation and lifetimes. These rate constants were combined in an M/M/∞ governing equation to predict the number of PS and WF in VF episodes. Observed distributions were compared to those predicted by the M/M/∞ equation. RESULTS: The M/M/∞ equation accurately predicted average PS and WF number and population distribution, demonstrated in all epochs. Self-terminating episodes of VF were distinguished from VF episodes requiring termination by a trend toward slower PS destruction, slower rates of PS formation, and a slower mixing rate of the VF process, indicated by larger values of the second largest eigenvalue modulus of the M/M/∞ birth-death matrix. The longest-lasting PS (associated with rotors) had shorter interactivation time intervals compared to shorter-lasting PS lasting <150 ms (∼1 PS rotation in human VF). CONCLUSION: The M/M/∞ equation explains the number of wavelets and rotors observed, supporting a paradigm of VF based on statistical fibrillatory dynamics.


Assuntos
Morte Súbita Cardíaca/etiologia , Fibrilação Ventricular/fisiopatologia , Procedimentos Cirúrgicos Cardíacos , Mapeamento Epicárdico , Feminino , Sistema de Condução Cardíaco/fisiopatologia , Humanos , Masculino , Cadeias de Markov , Modelos Cardiovasculares
2.
Heart Rhythm ; 18(8): 1406-1413, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33932588

RESUMO

BACKGROUND: Inhomogeneity of ventricular contraction is associated with sudden cardiac death, but the underlying mechanisms are unclear. Alterations in cardiac contraction impact electrophysiological parameters through mechanoelectric feedback. This has been shown to promote arrhythmias in experimental studies, but its effect in the in vivo human heart is unclear. OBJECTIVE: The purpose of this study was to quantify the impact of regional myocardial deformation provoked by a sudden increase in ventricular loading (aortic occlusion) on human cardiac electrophysiology. METHODS: In 10 patients undergoing open heart cardiac surgery, left ventricular (LV) afterload was modified by transient aortic occlusion. Simultaneous assessment of whole-heart electrophysiology and LV deformation was performed using an epicardial sock (240 electrodes) and speckle-tracking transesophageal echocardiography. Parameters were matched to 6 American Heart Association LV model segments. The association between changes in regional myocardial segment length and activation-recovery interval (ARI; a conventional surrogate for action potential duration) was studied using mixed-effect models. RESULTS: Increased ventricular loading reduced longitudinal shortening (P = .01) and shortened ARI (P = .02), but changes were heterogeneous between cardiac segments. Increased regional longitudinal shortening was associated with ARI shortening (effect size 0.20 [0.01-0.38] ms/%; P = .04) and increased local ARI dispersion (effect size -0.13 [-0.23 to -0.03] ms/%; P = .04). At the whole organ level, increased mechanical dispersion translated into increased dispersion of repolarization (correlation coefficient r = 0.81; P = .01). CONCLUSION: Mechanoelectric feedback can establish a potentially proarrhythmic substrate in the human heart and should be considered to advance our understanding and prevention of cardiac arrhythmias.


Assuntos
Arritmias Cardíacas/fisiopatologia , Eletrocardiografia , Retroalimentação , Sistema de Condução Cardíaco/fisiopatologia , Ventrículos do Coração/fisiopatologia , Contração Miocárdica/fisiologia , Idoso , Arritmias Cardíacas/diagnóstico , Ecocardiografia , Feminino , Ventrículos do Coração/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA