Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Am Coll Cardiol ; 79(25): 2471-2485, 2022 06 28.
Artigo em Inglês | MEDLINE | ID: mdl-35738707

RESUMO

BACKGROUND: The impact of pre-existing atrial fibrillation (AF) on outcomes after noncardiac surgery is not clear. OBJECTIVES: We aimed to study the impact of AF on the risk of adverse outcomes after noncardiac surgery in a nationwide cohort. METHODS: We identified Medicare beneficiaries admitted for noncardiac surgery from 2015 to 2019 and divided the study cohort into 2 groups: with and without AF. Noncardiac surgery was classified into vascular, thoracic, general, genitourinary, gynecological, orthopedics and neurosurgery, breast, head and neck, and transplant. We used propensity score matching on exact age, sex, race, urgency and type of surgery, revised cardiac risk index (RCRI) and CHA2DS2-VASc score, and tight caliper on other comorbidities. The study outcomes were 30-day mortality, stroke, myocardial infarction, and heart failure. We examined the incremental utility of AF in addition to RCRI to predict adverse events after noncardiac surgery. RESULTS: The study cohort included 8,635,758 patients who underwent noncardiac surgery (16.4% with AF). Patients with AF were older, more likely to be men, and had higher prevalence of comorbidities. After propensity score matching, AF was associated with higher risk of mortality (OR: 1.31; 95% CI: 1.30-1.32), heart failure (OR: 1.31; 95% CI: 1.30-1.33), and stroke (OR: 1.40; 95% CI: 1.37-1.43) and lower risk of myocardial infarction (OR: 0.81; 95% CI: 0.79-0.82). Results were consistent in subgroup analysis by sex, race, type of surgery, and all strata of RCRI and CHA2DS2-VASc score. AF improved the discriminative ability of RCRI (C-statistic 0.73 to 0.76). CONCLUSION: Pre-existing AF is independently associated with postoperative adverse outcomes after NCS.


Assuntos
Fibrilação Atrial , Insuficiência Cardíaca , Infarto do Miocárdio , Acidente Vascular Cerebral , Idoso , Fibrilação Atrial/complicações , Feminino , Humanos , Masculino , Medicare , Infarto do Miocárdio/complicações , Medição de Risco/métodos , Fatores de Risco , Acidente Vascular Cerebral/complicações , Acidente Vascular Cerebral/etiologia , Estados Unidos/epidemiologia
2.
Heart Rhythm ; 9(10): 1619-26, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22772136

RESUMO

BACKGROUND: A significant proportion of implantable cardioverter-defibrillators (ICDs) have been subject to Food and Drug Administration (FDA) advisories. The impact of device advisories on mortality or patient care is poorly understood. Although estimated risks of ICD generators under advisory are low, dependency on ICD therapies to prevent sudden death justifies the assessment of long-term mortality. OBJECTIVE: To test the association of FDA advisory status with long-term mortality. METHODS: The study was a retrospective, single-center review of clinical outcomes, including device malfunctions, in patients from implantation to either explant or death. Patients with ICDs first implanted at Cleveland Clinic between August 1996 and May 2004 who became subject to FDA advisories on ICD generators were identified. Mortality was determined by using the Social Security Death Index. RESULTS: In 1644 consecutive patients receiving first ICD implants, 704 (43%) became subject to an FDA advisory, of which 172 (10.5%) were class I and 532 (32.3%) were class II. ICDs were explanted before advisory notifications in 14.0% of class I and 10.1% of class II advisories. Among ICDs under advisory, 28 (4.0%) advisory-related and 15 non-advisory- related malfunctions were documented. Over a median follow-up of 70 months, 814 patients died. Kaplan-Meier 5-year survival rate was 65.6% overall, and 64.2, 61.1, and 69.3% in patients with no, class I, and class II advisories, respectively (P = .17). CONCLUSIONS: ICD advisories impacted 43% of the patients. Advisory-related malfunctions affected 4% within the combined advisory group. Based on a conservative management strategy, ICDs under advisory were not associated with increased mortality over a background of significant disease-related mortality.


Assuntos
Arritmias Cardíacas/mortalidade , Arritmias Cardíacas/terapia , Desfibriladores Implantáveis/efeitos adversos , Vigilância de Produtos Comercializados , Distribuição de Qui-Quadrado , Remoção de Dispositivo , Falha de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Modelos de Riscos Proporcionais , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Análise de Sobrevida , Estados Unidos , United States Food and Drug Administration
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA