Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Bases de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Skeletal Radiol ; 53(4): 733-739, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37857750

RESUMO

OBJECTIVE: To determine T2* normal reference values for anterior talofibular ligament (ATFL) and to investigate the feasibility of the quantitative ATFL quality evaluation in chronic lateral ankle instability (CLAI) using T2* values. MATERIALS AND METHODS: This study enrolled 15 patients with CLAI and 30 healthy volunteers. The entire ATFL T2* values from the MRI T2* mapping were measured. The prediction equation (variables: age, height, and weight) in a multiple linear regression model was used to calculate the T2* normal reference value in the healthy group. T2* ratio was defined as the ratio of the actual T2* value of the patient's ATFL to the normal reference value for each patient. A Telos device was used to measure the talar tilt angle (TTA) from the stress radiograph. RESULTS: T2* values of ATFL in the healthy and CLAI groups were 10.82 ± 1.84 ms and 14.36 ± 4.30 ms, respectively, which are significantly higher in the CLAI group (P < 0.05). The prediction equation of the normal reference T2* value was [14.9 + 0.14 × age (years) - 4.7 × height (m) - 0.03 × weight (kg)] (R2 = 0.65, P < 0.0001). A significant positive correlation was found between the T2* ratio and TTA (r = 0.66, P = 0.007). CONCLUSION: MRI T2* values in patients with CLAI were higher than those in healthy participants, and the T2* ratio correlated with TTA, suggesting that T2* values are promising for quantitative assessment of ATFL quality preoperatively.


Assuntos
Traumatismos do Tornozelo , Instabilidade Articular , Ligamentos Laterais do Tornozelo , Humanos , Articulação do Tornozelo/diagnóstico por imagem , Articulação do Tornozelo/cirurgia , Tornozelo , Traumatismos do Tornozelo/cirurgia , Ligamentos Laterais do Tornozelo/diagnóstico por imagem , Ligamentos Laterais do Tornozelo/cirurgia , Imageamento por Ressonância Magnética/métodos , Instabilidade Articular/cirurgia
3.
J Am Soc Echocardiogr ; 15(10 Pt 1): 1074-9, 2002 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-12373249

RESUMO

The aim of this study was to evaluate whether coronary flow velocity (CFV) and coronary flow velocity reserve (CFVR) in the posterior descending right coronary artery can be reliably measured by transthoracic Doppler echocardiography (TTDE). In 17 patients, CFV in the posterior descending right coronary artery was measured with TTDE at the time of Doppler guidewire examination. CFV was measured by both methods at baseline and under hyperemic conditions. TTDE data were obtained for 12 patients. CFV and CFVR by TTDE show a good correlation with those obtained by the Doppler guidewire method (average diastolic peak velocity: r = 0.98, y = 0.85x + 5.26; diastolic peak velocity: r = 0.97, y = 0.94x + 3.39; CFVR: r = 0.97, y = 0.87x + 0.56). CFV and CFVR in the posterior descending right coronary artery obtained noninvasively by TTDE accurately reflect these values obtained by the invasive Doppler guidewire method.


Assuntos
Velocidade do Fluxo Sanguíneo/fisiologia , Circulação Coronária/fisiologia , Vasos Coronários/diagnóstico por imagem , Ecocardiografia Doppler/instrumentação , Idoso , Vasos Coronários/fisiologia , Ecocardiografia/instrumentação , Ecocardiografia/métodos , Feminino , Humanos , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA