Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
J Vet Med Sci ; 84(10): 1385-1390, 2022 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-36031362

RESUMO

A 12-year-old neutered male Chihuahua was diagnosed with acute brain infarction in the right middle cerebral artery (MCA) territory. Transcranial Doppler ultrasonography (TCD) was performed to assess the local cerebral blood flow at the time of diagnosis and after 4 and 31 hr. Initially, the right MCA retained blood flow but with a lower cerebral blood flow velocity (CBFV; 14.9 cm/sec) than the left MCA (27.9 cm/sec). The TCD vascular resistance variables were higher in the right than in the left MCA. An increase in the CBFV and a decrease in TCD vascular resistance variables were observed, consistent with improvements in neurological symptoms. TCD can be a non-invasive, and easy-to-use modality for bedside monitoring of cerebral edema and infarction.


Assuntos
Doenças do Cão , Ultrassonografia Doppler Transcraniana , Animais , Velocidade do Fluxo Sanguíneo/fisiologia , Velocidade do Fluxo Sanguíneo/veterinária , Infarto Encefálico/veterinária , Circulação Cerebrovascular , Cães , Masculino , Artéria Cerebral Média/diagnóstico por imagem , Ultrassonografia Doppler Transcraniana/veterinária
2.
Sci Total Environ ; 842: 156490, 2022 Oct 10.
Artigo em Inglês | MEDLINE | ID: mdl-35667425

RESUMO

Companion animals are in close contact with the human surroundings, and there is growing concern about the effects of harmful substances on the health of pet cats. In this study, we investigated the potential health effects of organohalogen compounds (OHCs) on thyroid hormone (TH) homeostasis and metabolomics in Japanese pet cats. There was a significant negative correlation between concentrations of several contaminants, such as polychlorinated biphenyls (PCBs), polybrominated diphenyl ethers (PBDEs), hydroxylated PCBs (OH-PCBs), hydroxylated PBDEs (OH-PBDEs), and THs in cat serum samples. These results suggested that exposure to OHCs causes a decrease in serum TH levels in pet cats. In this metabolomics study, each exposure level of parent compounds (PCBs and PBDEs) and their hydroxylated compounds (OH-PCBs and OH-PBDEs) were associated with their own unique primary metabolic pathways, suggesting that parent and phenolic compounds exhibit different mechanisms of action and biological effects. PCBs were associated with many metabolic pathways, including glutathione and purine metabolism, and the effects were replicated in in-vivo cat PCB administration studies. These results demonstrated that OHC exposure causes chronic oxidative stress in pet cats. PBDEs were positively associated with alanine, aspartate, and glutamate metabolism. Due to the chronic exposure of cats to mixtures of these contaminants, the combination of their respective metabolic pathways may have a synergistic effect.


Assuntos
Poluentes Ambientais , Bifenilos Policlorados , Animais , Gatos , Poluentes Ambientais/toxicidade , Éteres Difenil Halogenados/metabolismo , Avaliação do Impacto na Saúde , Humanos , Metabolômica , Bifenilos Policlorados/metabolismo , Hormônios Tireóideos
3.
Front Pharmacol ; 13: 837754, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35370726

RESUMO

Intravesical chemotherapy after transurethral resection is a treatment option in patients with non-muscle invasive bladder cancer. The efficacy of intravesical chemotherapy is determined by the cellular uptake of intravesical drugs. Therefore, drug delivery technologies in the urinary bladder are promising tools for enhancing the efficacy of intravesical chemotherapy. Ultrasound-triggered microbubble cavitation may enhance the permeability of the urothelium, and thus may have potential as a drug delivery technology in the urinary bladder. Meanwhile, the enhanced permeability may increase systemic absorption of intravesical drugs, which may increase the adverse effects of the drug. The aim of this preliminary safety study was to assess the systemic absorption of an intravesical drug that was delivered by ultrasound-triggered microbubble cavitation in the urinary bladder of normal dogs. Pirarubicin, a derivative of doxorubicin, and an ultrasound contrast agent (Sonazoid) microbubbles were administered in the urinary bladder. Ultrasound (transmitting frequency 5 MHz; pulse duration 0.44 µsec; pulse repetition frequency 7.7 kHz; peak negative pressure -1.2 MPa) was exposed to the bladder using a diagnostic ultrasound probe (PLT-704SBT). The combination of ultrasound and microbubbles did not increase the plasma concentration of intravesical pirarubicin. In addition, hematoxylin and eosin staining showed that the combination of ultrasound and microbubble did not cause observable damages to the urothelium. Tissue pirarubicin concentration in the sonicated region was higher than that of the non-sonicated region in two of three dogs. The results of this pilot study demonstrate the safety of the combination of intravesical pirarubicin and ultrasound-triggered microbubble cavitation, that is, ultrasound-assisted intravesical chemotherapy.

4.
J Vet Intern Med ; 33(5): 2067-2074, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31461576

RESUMO

BACKGROUND: Two-dimensional shear wave elastography (2D-SWE) can noninvasively evaluate hepatic elastic modulus as shear wave velocity (SWV). Additionally, it may predict the presence of clinical relevant hepatic fibrosis (≥F2) in dogs with hepatic disease. OBJECTIVES: To investigate whether SWV measured by 2D-SWE can differentiate between dogs with (≥F2) and without (F0-1) clinically relevant hepatic fibrosis. ANIMALS: Twenty-eight client-owned dogs with hepatic disease and 8 normal healthy Beagle dogs were enrolled. METHODS: In this cross-sectional prospective study, SWVs were measured using 2D-SWE in all dogs. Hepatic fibrosis stages and necroinflammatory activity grades were histopathologically evaluated using a histological scoring scheme that was adapted from the Ishak schema used in human medicine. RESULTS: Median SWVs were significantly higher in dogs with clinically relevant hepatic fibrosis (2.04 m/s; range, 1.81-2.26 m/s) than in healthy dogs (1.51 m/s; range, 1.44-1.66 m/s; P = .007), and dogs without clinically relevant hepatic fibrosis (1.56 m/s; range, 1.37-1.67 m/s; P < .001). However, no significant difference was found in the SWVs between dogs without clinically relevant hepatic fibrosis and healthy dogs (P = .99). Furthermore, median SWVs were not significantly different among dogs with necroinflammatory activity, those without necroinflammatory activity, and healthy dogs (Kruskal-Wallis test, P = .12). CONCLUSIONS AND CLINICAL IMPORTANCE: The 2D-SWE may be useful for predicting the presence of hepatic fibrosis in dogs with hepatic disease.


Assuntos
Técnicas de Imagem por Elasticidade/veterinária , Cirrose Hepática/veterinária , Hepatopatias/veterinária , Animais , Estudos Transversais , Cães , Técnicas de Imagem por Elasticidade/métodos , Feminino , Inflamação/patologia , Inflamação/veterinária , Fígado/patologia , Cirrose Hepática/diagnóstico por imagem , Hepatopatias/diagnóstico por imagem , Masculino , Estudos Prospectivos
5.
Am J Vet Res ; 78(4): 465-471, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28346001

RESUMO

OBJECTIVE To assess the use of contrast-enhanced ultrasonography (CEUS) of the hepatic vein for the detection of hemodynamic changes associated with experimentally induced portal hypertension in dogs. ANIMALS 6 healthy Beagles. PROCEDURES A prospective study was conducted. A catheter was surgically placed in the portal vein of each dog. Hypertension was induced by intraportal injection of microspheres (10 to 15 mg/kg) at 5-day intervals via the catheter. Microsphere injections were continued until multiple acquired portosystemic shunts were created. Portal vein pressure (PVP) was measured through the catheter. Contrast-enhanced ultrasonography was performed before and after establishment of hypertension. Time-intensity curves were generated from the region of interest in the hepatic vein. Perfusion variables measured for statistical analysis were hepatic vein arrival time, time to peak, time to peak phase (TTPP), and washout ratio. The correlation between CEUS variables and PVP was assessed by use of simple regression analysis. RESULTS Time to peak and TTPP were significantly less after induction of portal hypertension. Simple regression analysis revealed a significant negative correlation between TTPP and PVP. CONCLUSIONS AND CLINICAL RELEVANCE CEUS was useful for detecting hemodynamic changes associated with experimentally induced portal hypertension in dogs, which was characterized by a rapid increase in the intensity of the hepatic vein. Furthermore, TTPP, a time-dependent variable, provided useful complementary information for predicting portal hypertension. IMPACT FOR HUMAN MEDICINE Because the method described here induced presinusoidal portal hypertension, these results can be applied to idiopathic portal hypertension in humans.


Assuntos
Doenças do Cão/diagnóstico por imagem , Hemodinâmica , Veias Hepáticas/diagnóstico por imagem , Hipertensão Portal/veterinária , Ultrassonografia/veterinária , Animais , Meios de Contraste , Cães , Humanos , Hipertensão Portal/diagnóstico por imagem , Cirrose Hepática , Masculino , Microesferas , Pancitopenia , Perfusão , Veia Porta , Estudos Prospectivos , Esplenomegalia , Ultrassonografia/métodos , Hipertensão Portal não Cirrótica Idiopática
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA