Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Ophthalmology ; 131(2): 227-239, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38069945

RESUMO

PURPOSE: To evaluate the recently published literature on the efficacy and safety of the use of aqueous shunts with extraocular reservoir for the management of adult open-angle glaucomas (OAGs). METHODS: A search of peer-reviewed literature was last conducted in April 2023 of the PubMed database and included only articles published since the last aqueous shunt Ophthalmic Technology Assessment, which assessed articles published before 2008. The abstracts of these 419 articles were examined, and 58 studies were selected for full-text analysis. After inclusion and exclusion criteria were applied, 28 articles were selected and assigned ratings by the panel methodologist according to the level of evidence. Twenty-five articles were rated level I and 3 articles were rated level II. There were no level III articles. RESULTS: Implantation of aqueous shunts with extraocular reservoir can lower intraocular pressure (IOP) by between one-third and one-half of baseline IOP, depending on whether it is undertaken as the primary or secondary glaucoma surgery. Success rates for aqueous shunts were found to be better than for trabeculectomies in eyes with prior incisional surgery. Conversely, in eyes without prior incisional surgery, implantation of aqueous shunts was found to have an overall lower success rate as the primary glaucoma procedure compared with trabeculectomy. Although both valved and nonvalved aqueous shunts with extraocular reservoir were effective, the nonvalved device generally achieved slightly lower long-term IOPs with fewer glaucoma medications and less need for additional glaucoma surgery. Both devices slow the rates of visual field progression with efficacy comparable with that of trabeculectomy. Early aqueous humor suppression after aqueous shunt implantation is recommended for the management of the postoperative hypertensive phase and long-term IOP control. No strong evidence supports the routine use of mitomycin C with aqueous shunt implantation for OAG. CONCLUSIONS: Implantation of aqueous shunts with extraocular reservoir, including valved or nonvalved devices, has been shown to be an effective strategy to lower IOP. Strong level I evidence supports the use of aqueous shunts with extraocular reservoir by clinicians for the management of adult OAG. FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.


Assuntos
Implantes para Drenagem de Glaucoma , Glaucoma de Ângulo Aberto , Glaucoma , Oftalmologia , Trabeculectomia , Adulto , Humanos , Estados Unidos , Glaucoma/cirurgia , Glaucoma de Ângulo Aberto/cirurgia , Pressão Intraocular , Trabeculectomia/métodos , Resultado do Tratamento
2.
Ophthalmology ; 131(1): 37-47, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37702635

RESUMO

PURPOSE: To review the current published literature for high-quality studies on the use of selective laser trabeculoplasty (SLT) for the treatment of glaucoma. This is an update of the Ophthalmic Technology Assessment titled, "Laser Trabeculoplasty for Open-Angle Glaucoma," published in November 2011. METHODS: Literature searches in the PubMed database in March 2020, September 2021, August 2022, and March 2023 yielded 110 articles. The abstracts of these articles were examined to include those written since November 2011 and to exclude reviews and non-English articles. The panel reviewed 47 articles in full text, and 30 were found to fit the inclusion criteria. The panel methodologist assigned a level I rating to 19 studies and a level II rating to 11 studies. RESULTS: Data in the level I studies support the long-term effectiveness of SLT as primary treatment or as a supplemental therapy to glaucoma medications for patients with open-angle glaucoma. Several level I studies also found that SLT and argon laser trabeculoplasty (ALT) are equivalent in terms of safety and long-term efficacy. Level I evidence indicates that perioperative corticosteroid and nonsteroidal anti-inflammatory drug eye drops do not hinder the intraocular pressure (IOP)-lowering effect of SLT treatment. The impact of these eye drops on lowering IOP differed in various studies. No level I or II studies exist that determine the ideal power settings for SLT. CONCLUSIONS: Based on level I evidence, SLT is an effective long-term option for the treatment of open-angle glaucoma and is equivalent to ALT. It can be used as either a primary intervention, a replacement for medication, or an additional therapy with glaucoma medications. FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.


Assuntos
Glaucoma de Ângulo Aberto , Glaucoma , Oftalmologia , Trabeculectomia , Humanos , Glaucoma/cirurgia , Glaucoma de Ângulo Aberto/cirurgia , Lasers , Soluções Oftálmicas , Malha Trabecular/cirurgia , Estados Unidos
3.
Ophthalmology ; 130(4): 433-442, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36529572

RESUMO

PURPOSE: To review the current published literature on the utility of corneal hysteresis (CH) to assist the clinician in the diagnosis of glaucoma or in the assessment of risk for disease progression in existing glaucoma patients. METHODS: Searches of the peer-reviewed literature in the PubMed database were performed through July 2022. The abstracts of 423 identified articles were examined to exclude reviews and non-English articles. After inclusion and exclusion criteria were applied, 19 articles were selected, and the panel methodologist rated them for level of evidence. Eight articles were rated level I, and 5 articles were rated level II. The 6 articles rated level III were excluded. RESULTS: Corneal hysteresis is lower in patients with primary open-angle glaucoma, primary angle-closure glaucoma, pseudoexfoliative glaucoma, and pseudoexfoliation syndrome compared with normal subjects. Interpretation of low CH in patients with high intraocular pressure (IOP) or on topical hypotensive medications is complicated by the influence of these parameters on CH measurements. However, CH is also lower in treatment-naïve, normal-tension glaucoma patients compared with normal subjects who have a similar IOP. In addition, lower CH is associated with an increased risk of progression of glaucoma based on visual fields or structural markers in open-angle glaucoma patients, including those with apparently well-controlled IOP. CONCLUSIONS: Corneal hysteresis is lower in glaucoma patients compared with normal subjects, and lower CH is associated with an increased risk of disease progression. However, a causal relationship remains to be demonstrated. Nevertheless, measurement of CH complements current structural and functional assessments in determining disease risk in glaucoma suspects and patients. FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found after the references.


Assuntos
Glaucoma de Ângulo Aberto , Glaucoma , Oftalmologia , Humanos , Fenômenos Biomecânicos , Córnea/diagnóstico por imagem , Progressão da Doença , Elasticidade , Glaucoma/diagnóstico , Glaucoma de Ângulo Aberto/diagnóstico , Pressão Intraocular , Tonometria Ocular , Estados Unidos
4.
Ophthalmology ; 128(8): 1222-1235, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33632585

RESUMO

PURPOSE: To review the current published literature on the use of OCT angiography (OCTA) to help detect changes associated with the diagnosis of primary open-angle glaucoma. METHODS: Searches of the peer-reviewed literature were conducted in March 2018, June 2018, April 2019, December 2019, and June 2020 in the PubMed and Cochrane Library databases. Abstracts of 459 articles were examined to exclude reviews and non-English articles. After inclusion and exclusion criteria were applied, 75 articles were selected and the panel methodologist rated them for strength of evidence. Three articles were rated level I and 57 articles were rated level II. The 15 level III articles were excluded. RESULTS: OCT angiography can detect decreased capillary vessel density within the peripapillary nerve fiber layer (level II) and macula (level I and II) in patients with suspected glaucoma, preperimetric glaucoma, and perimetric glaucoma. The degree of vessel density loss correlates significantly with glaucoma severity both overall and topographically (level II) as well as longitudinally (level I). For differentiating glaucomatous from healthy eyes, some studies found that peripapillary and macular vessel density measurements by OCTA show a diagnostic ability (area under the receiver operating characteristic curve) that is comparable with structural OCT retinal nerve fiber and ganglion cell thickness measurements, whereas other studies found that structural OCT measurements perform better. Choroidal or deep-layer microvasculature dropout as measured by OCTA is also associated with glaucoma damage (level I and II). Lower peripapillary and macular vessel density and choroidal microvasculature dropout are associated with faster rates of disease progression (level I and II). CONCLUSIONS: Vessel density loss associated with glaucoma can be detected by OCTA. Peripapillary, macular, and choroidal vessel density parameters may complement visual field and structural OCT measurements in the diagnosis of glaucoma.


Assuntos
Angiofluoresceinografia , Glaucoma de Ângulo Aberto/diagnóstico , Oftalmologia/organização & administração , Vasos Retinianos/fisiologia , Tomografia de Coerência Óptica , Academias e Institutos , Feminino , Glaucoma de Ângulo Aberto/fisiopatologia , Humanos , Masculino , Fibras Nervosas/patologia , Disco Óptico/irrigação sanguínea , Estudos Prospectivos , Curva ROC , Células Ganglionares da Retina/patologia , Avaliação da Tecnologia Biomédica/métodos
5.
Ophthalmology ; 126(9): 1315-1323, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-30953743

RESUMO

PURPOSE: To review the published literature on the use of swept-source (SS) OCT for evaluating the lamina cribrosa in glaucoma. METHODS: A PubMed and Cochrane Library literature search initially conducted on March 3, 2017, and updated on June 26, 2018, yielded a total of 64 articles. Articles that were reviews or that were not published in English were excluded, and 29 were found to fit the inclusion criteria. The panel methodologist then assigned a level of evidence rating to each study. Fifteen studies were rated level III, 14 studies were rated level II, and no studies were rated level I. RESULTS: Different aspects of the lamina cribrosa were studied using SS-OCT, including the anterior lamina cribrosa curvature, anterior lamina cribrosa depth, anterior lamina cribrosa insertions, laminar thickness, focal lamina cribrosa defects (FLCDs), and lamina cribrosa microarchitecture. In general, imaging of the anterior lamina can be achieved reliably, although shadowing from blood vessels at the neuroretinal rim remains an issue. Imaging of the posterior lamina can be achieved with varying levels of success. In glaucoma, there is posterior migration of the anterior lamina cribrosa insertions as well as increased thinning and posterior curvature of the lamina cribrosa. Focal lamina cribrosa defects appear more commonly in glaucoma, and this may hint at the pathogenesis of axonal damage. In addition, there may be remodeling of the microarchitecture of the lamina, resulting in more variable laminar pores. There are limited studies comparing SS-OCT with spectral-domain (SD) OCT with regard to imaging of the lamina, but the difference in image quality between enhanced depth imaging (EDI) with SD-OCT and SS-OCT seems minimal. CONCLUSIONS: Imaging of the lamina cribrosa using SS-OCT has demonstrated that the lamina cribrosa is likely biomechanically active and that significant changes occur in glaucoma. The diagnostic utility of SS-OCT for lamina cribrosa imaging is promising, but standardized nomenclature, automated measurements, and longitudinal studies with larger and more diverse sample sizes are needed.


Assuntos
Glaucoma de Ângulo Aberto/diagnóstico por imagem , Disco Óptico/diagnóstico por imagem , Doenças do Nervo Óptico/diagnóstico por imagem , Avaliação da Tecnologia Biomédica , Tomografia de Coerência Óptica/métodos , Academias e Institutos/organização & administração , Bases de Dados Factuais , Humanos , Fibras Nervosas/patologia , Oftalmologia/organização & administração , Disco Óptico/patologia , Células Ganglionares da Retina/patologia , Estados Unidos
6.
Ophthalmology ; 126(4): 611-622, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30472176

RESUMO

PURPOSE: To assess the effect of intravitreal injections of anti-vascular endothelial growth factor (VEGF) agents on immediate and long-term intraocular pressure (IOP) elevation and glaucoma. METHODS: Literature searches of the PubMed and Cochrane databases, last conducted in April 2018, yielded 253 unique citations. Of these, 41 met the inclusion criteria and were rated according to the strength of evidence. Two articles were rated level I, 17 were rated level II, and 15 were rated level III; an additional 7 were excluded because of poor study design and lack of relevance to the topic under evaluation. RESULTS: The studies that reported on short-term IOP elevation (i.e., between 0 and 60 minutes) showed that an immediate increase in IOP is seen in all patients when measured between 0 and 30 minutes of intravitreal injection and that the IOP elevation decreases over time. The data on long-term IOP elevation were mixed; 7 studies reported that between 4% and 15% of patients developed sustained elevation of IOP at 9 to 24 months after injection, whereas 6 studies found no long-term change in IOP from 1 to 36 months after injection. Pretreatment with glaucoma medications, anterior chamber tap, vitreous reflux, longer intervals between injections, and longer axial lengths were associated with lower IOP elevations after injection. Data were mixed on the relationship between IOP increase and the type of intravitreal injection, number of intravitreal injections, preexisting glaucoma, and globe decompression before injection. There were no data on the onset or progression of glaucoma in the studies reviewed in this assessment. CONCLUSIONS: Intravitreal injection of anti-VEGF agents results in an immediate and transient increase in IOP. A long-term increase in IOP also may be seen, and further studies are needed to determine at-risk populations. Although there is some suggestion in the literature, there is currently insufficient data to determine the impact of intravitreal anti-VEGF injections on glaucoma progression. Although pretreatment with glaucoma medications, performing anterior chamber paracentesis, or increasing the interval between injections may reduce the impact of transient IOP elevation, the clinical significance and associated risks of these interventions are unknown.


Assuntos
Inibidores da Angiogênese/farmacologia , Glaucoma/fisiopatologia , Pressão Intraocular/efeitos dos fármacos , Fator A de Crescimento do Endotélio Vascular/antagonistas & inibidores , Academias e Institutos/organização & administração , Bases de Dados Factuais , Glaucoma/diagnóstico , Humanos , Pressão Intraocular/fisiologia , Injeções Intravítreas , Avaliação da Tecnologia Biomédica , Estados Unidos
7.
Ophthalmology ; 125(11): 1817-1827, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30322450

RESUMO

PURPOSE: To review the current published literature on the use of spectral domain (SD) OCT to help detect changes associated with the diagnosis of glaucoma. METHODS: Searches of the peer-reviewed literature were conducted on June 11, 2014, November 7, 2016, August 8, 2017, and April 19, 2018, in the PubMed and Cochrane Library databases and included only articles published since the last glaucoma imaging Ophthalmic Technology Assessment, which included articles up until February 2006. The abstracts of these 708 articles were examined to exclude reviews and non-English articles. After inclusion and exclusion criteria were applied, 74 articles were selected, and the panel methodologist (K.N.-M.) assigned ratings to them according to the level of evidence. Two articles were rated level I, 57 articles were rated level II, and the 15 level III articles were excluded. RESULTS: Spectral-domain OCT is capable of detecting damage to the retinal nerve fiber layer (RNFL), macula, and optic nerve in patients with preperimetric and perimetric glaucoma (level I and II evidence). The most commonly studied single parameter was RNFL thickness. Of note, RNFL thickness measurements are not interchangeable between instruments. Various commercially available SD OCT instruments have similar abilities to distinguish patients with known glaucoma from normal subjects. Despite different software protocols, all SD OCT instruments are able to detect the same typical pattern of glaucomatous RNFL loss that affects primarily the inferior, inferior temporal, superior, and superior temporal regions of the optic nerve (level II evidence). Across many SD OCT instruments, macular imaging also can detect a preferential inferior, inferior temporal, and superior temporal thinning in patients with glaucoma compared with controls. Best disc parameters for detecting glaucomatous nerve damage are global rim area, inferior rim area, and vertical cup-to-disc ratio. Studies suggest that newer reference-plane independent optic nerve parameters may have the same or better detection capability when compared with older reference-plane dependent disc parameters (level II evidence). CONCLUSIONS: Structural glaucomatous damage can be detected by SD OCT. Optic nerve, RNFL, and macular parameters can help the clinician distinguish the anatomic changes that are associated with patients with glaucoma when compared with normal subjects.


Assuntos
Glaucoma de Ângulo Aberto/diagnóstico por imagem , Fibras Nervosas/patologia , Disco Óptico/diagnóstico por imagem , Doenças do Nervo Óptico/diagnóstico por imagem , Células Ganglionares da Retina/patologia , Tomografia de Coerência Óptica/métodos , Academias e Institutos/organização & administração , Bases de Dados Factuais , Humanos , Oftalmologia/organização & administração , Avaliação da Tecnologia Biomédica , Estados Unidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA