Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Abdom Radiol (NY) ; 45(12): 4273-4289, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32936417

RESUMO

Pancreatic ductal adenocarcinoma (PDA) is the third leading cause of cancer-related death in the United States and is projected to be the second by 2030. Systemic combination chemotherapy is considered an essential first-line treatment for the majority of patients with PDA, in both the neoadjuvant and palliative settings. In addition, a number of novel therapies are being tested in clinical trials for patients with advanced PDA. In all cases, accurate and timely assessment of treatment response is critical to guide therapy, reduce drug toxicities and cost from a failing therapy, and aid adaptive clinical trials. Conventional morphological imaging has significant limitations, especially in the context of determining primary tumor response and resectability following neoadjuvant therapies. In this article, we provide an overview of current therapy options for PDA, highlight several morphological imaging findings that may be helpful to reduce over-staging following neoadjuvant therapy, and discuss a number of emerging imaging, and non-imaging, tools that have shown promise in providing a more precise quantification of disease burden and treatment response in PDA.


Assuntos
Adenocarcinoma , Carcinoma Ductal Pancreático , Neoplasias Pancreáticas , Radiologia , Carcinoma Ductal Pancreático/diagnóstico por imagem , Carcinoma Ductal Pancreático/terapia , Humanos , Neoplasias Pancreáticas/diagnóstico por imagem , Neoplasias Pancreáticas/tratamento farmacológico , Radiografia Abdominal
2.
AJR Am J Roentgenol ; 215(1): 50-57, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32286872

RESUMO

OBJECTIVE. The purpose of this study was to perform quantitative and qualitative evaluation of a deep learning image reconstruction (DLIR) algorithm in contrast-enhanced oncologic CT of the abdomen. MATERIALS AND METHODS. Retrospective review (April-May 2019) of the cases of adults undergoing oncologic staging with portal venous phase abdominal CT was conducted for evaluation of standard 30% adaptive statistical iterative reconstruction V (30% ASIR-V) reconstruction compared with DLIR at low, medium, and high strengths. Attenuation and noise measurements were performed. Two radiologists, blinded to examination details, scored six categories while comparing reconstructions for overall image quality, lesion diagnostic confidence, artifacts, image noise and texture, lesion conspicuity, and resolution. RESULTS. DLIR had a better contrast-to-noise ratio than 30% ASIR-V did; high-strength DLIR performed the best. High-strength DLIR was associated with 47% reduction in noise, resulting in a 92-94% increase in contrast-to-noise ratio compared with that of 30% ASIR-V. For overall image quality and image noise and texture, DLIR scored significantly higher than 30% ASIR-V with significantly higher scores as DLIR strength increased. A total of 193 lesions were identified. The lesion diagnostic confidence, conspicuity, and artifact scores were significantly higher for all DLIR levels than for 30% ASIR-V. There was no significant difference in perceived resolution between the reconstruction methods. CONCLUSION. Compared with 30% ASIR-V, DLIR improved CT evaluation of the abdomen in the portal venous phase. DLIR strength should be chosen to balance the degree of desired denoising for a clinical task relative to mild blurring, which increases with progressively higher DLIR strengths.


Assuntos
Aprendizado Profundo , Neoplasias do Sistema Digestório/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Radiografia Abdominal , Neoplasias Torácicas/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Feminino , Humanos , Iohexol , Masculino , Pessoa de Meia-Idade , Doses de Radiação , Estudos Retrospectivos
3.
J Comput Assist Tomogr ; 40(5): 717-22, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27636124

RESUMO

PURPOSE: Our aim was to compare the interobserver and intraobserver variability for the measurement of the size of liver metastases in patients with carcinoid tumors with various magnetic resonance (MR) series. MATERIALS AND METHODS: In this retrospective institutional review board-approved study, 30 patients with liver metastases from a carcinoid primary had a complete MR examination of the abdomen at 1.5 T with gadolinium-ethoxybenzyl-diethylenetriamine pentaacetic acid (Gd-EOB-DTPA). The complete MR examination included T1 (in-phase [IP]/out-of-phase [OOP], T2, diffusion-weighted imaging, pre-Gd-EOB-DTPA and post-Gd-EOB-DTPA 3D gradient echo (4 phases plus 20-minute hepatobiliary phase [HBP] Gd]). Four readers reviewed each series independently. The measurement for each lesion was compared to HBP-Gd images. The sensitivity for detection of each lesion was compared to HBP-Gd. Variance component analysis was used to estimate variance due to patient, lesion within patient, and reader by sequence. Linear mixed model was used to compare lesion size between sequences. RESULTS: The HBP-Gd had the smallest interreader variability. There was no significant difference between series with respect to interreader variability. Lesion sizes measured in diffusion-weighted imaging was significantly higher. T2-weighted imaging was the closest to HBP-Gd. Lesion sizes measured with the other sequences were significantly smaller. There was significant difference in sensitivity of lesion detection of some series when compared to HBP-Gd. CONCLUSION: The HBP-Gd series had the smallest interreader variability and is the recommended series to measure lesion size for evaluation of response to treatment.


Assuntos
Gadolínio DTPA/administração & dosagem , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/secundário , Imageamento por Ressonância Magnética/métodos , Tumores Neuroendócrinos/diagnóstico por imagem , Tumores Neuroendócrinos/secundário , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Meios de Contraste/administração & dosagem , Esquema de Medicação , Feminino , Humanos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Neoplasias Hepáticas/patologia , Masculino , Pessoa de Meia-Idade , Tumores Neuroendócrinos/patologia , Variações Dependentes do Observador , Avaliação de Resultados em Cuidados de Saúde/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
4.
Abdom Radiol (NY) ; 41(7): 1317-24, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-26956643

RESUMO

PURPOSE: To determine the inter- and intra-reader agreement of size, conspicuity, and margin sharpness of pancreatic adenocarcinoma on monochromatic, polychromatic, and iodine map dual-energy CT (DECT) images. METHODS: Retrospective review of DECT images from 61 patients with untreated pancreatic adenocarcinoma was performed by three radiologists independently. Pancreatic parenchymal phase images were generated as 50 and 70 keV, 140 kVp quality control (QC), and iodine map images. These were analyzed in a blinded randomized order during four reading sessions separated by 5-7 days. For each image set, readers recorded the longest axial and perpendicular primary tumor dimensions, and qualitatively scored tumor conspicuity and edge sharpness on 5-point scales. Linear mixed model was used to estimate and compare tumor measurements, tumor conspicuity, and tumor edge sharpness scores between readers and image sets. Kappa statistics were used to determine inter-observer agreement for tumor conspicuity and edge sharpness. RESULTS: The range of tumor measures (mean of longest dimension ± standard deviation) was 3.18 ± 1.41 to 3.83 ± 1.57 cm. Reproducibility of tumor measurements was very high with mild variability (s (2) = 0.01-0.10) between readers for the different image sets. Inter-observer agreement values for tumor conspicuity (κ = 0.01-0.17) and edge sharpness (κ = 0.12-0.25) were low for all image sets, although two of three readers scored tumor conspicuity and edge sharpness higher on monochromatic and iodine map DECT images than on 140 kVp QC images (p < 0.05). CONCLUSIONS: Pancreatic adenocarcinoma measurements were highly reproducible on DECT images, and subjective reader preference trended toward monochromatic and iodine images rather than polychromatic images.


Assuntos
Adenocarcinoma/diagnóstico por imagem , Neoplasias Pancreáticas/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Reprodutibilidade dos Testes , Estudos Retrospectivos
5.
J Comput Assist Tomogr ; 39(6): 907-13, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26295192

RESUMO

PURPOSE: The aim of this study was to compare contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR) between pancreatic-phase dual-energy computed tomography (DECT) and 120-kVp CT for pancreatic ductal adenocarcinoma (PDA). MATERIALS AND METHODS: Seventy-eight patients underwent multiphasic pancreatic imaging protocols for PDA (40, DECT; 38, 120-kVp CT [control]). Using pancreatic phase, CNR and SNR for PDA were obtained for DECT at monochromatic energies 50 through 80 keV, iodine material density images, and 120-kVp images. Using a 5-point scale (1, excellent; 5, markedly limited), images were qualitatively assessed by 2 radiologists in consensus for PDA detection, extension, vascular involvement, and noise. Wilcoxon signed rank and 2-sample tests were used to compare the qualitative measures, CNR and SNR, for DECT and 120-kVp images. Bonferroni correction was applied. RESULTS: Iodine material density image had significantly higher CNR and SNR for PDA than any monochromatic energy images (P < 0.0001) and the 120-kVp images. Qualitatively, 70-keV images were rated highest in the categories of tumor extension and vascular invasion and were similar to 120-kVp images. CONCLUSIONS: Our results indicate that DECT improves PDA lesion conspicuity compared with routine 120-kVp CT, which may allow for better detection of PDA.


Assuntos
Carcinoma Ductal Pancreático/diagnóstico por imagem , Neoplasias Pancreáticas/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Meios de Contraste , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pâncreas/diagnóstico por imagem , Intensificação de Imagem Radiográfica , Razão Sinal-Ruído , Ácidos Tri-Iodobenzoicos
6.
Abdom Imaging ; 34(1): 64-74, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-18483805

RESUMO

The development of multidetector row computed tomography (MDCT) has led to the acquisition of true isotropic voxels that can be postprocessed to yield images in any plane of the same resolution as the original axially acquired images. This, coupled with rapid MDCT imaging during peak target organ enhancement has led to a variety of means to review imaging information beyond that of the axial perspective. Postprocessing can be utilized to identify variant biliary anatomy to guide preoperative planning of biliary-related surgery, determine the level and cause of biliary obstruction and assist in staging of biliary cancer. Postprocessing can also be used to identify pancreatic ductal variants, visualize diagnostic features of pancreatic cystic lesions, diagnose and stage pancreatic cancer, and differentiate pancreatic from peripancreatic disease.


Assuntos
Doenças Biliares/diagnóstico por imagem , Imageamento Tridimensional/métodos , Neoplasias Pancreáticas/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Doenças Biliares/patologia , Humanos , Neoplasias Pancreáticas/patologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA