Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Vaccines (Basel) ; 11(1)2023 Jan 06.
Artigo em Inglês | MEDLINE | ID: mdl-36679979

RESUMO

Post-renal-transplant patients have a relatively low antibody-acquisition rate following severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) mRNA vaccination. In this study, antibody titers were measured 5−6 months and 3 weeks to 3 months after the second and third SARS-CoV-2 mRNA vaccinations, respectively. Post-renal-transplant patients visiting our hospital who had received three SARS-CoV-2 mRNA vaccine doses were included in the study. SARS-CoV-2 immunoglobulin G antibody titers were measured three times: between 3 weeks and 3 months after the second vaccination, 5−6 months after the second vaccination, and between 3 weeks and 3 months after the third vaccination. A total of 62 (40 men and 22 women) were included, 44 of whom (71.0%) were antibody positive after their third vaccination. On comparing the antibody-acquired and antibody-non-acquired groups, body mass index (BMI, odds ratio [OR]: 1.44, 95% confidence interval [CI]: 1.07−1.93, p < 0.05) and the estimated glomerular filtration rate (eGFR, OR: 1.14, 95% CI: 1.06−1.24, p < 0.01) were associated with antibody acquisition. Therefore, in Japanese post-kidney-transplant patients, increases in the antibody-acquisition rate and absolute antibody titer after the third vaccination were observed, with BMI and eGFR associated with the antibody-acquisition rate.

2.
Heart Vessels ; 37(2): 219-228, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34365566

RESUMO

Low body mass index (BMI) is a predictor of adverse events in patients with ST-elevated myocardial infarction (STEMI) in Western countries. Because the average BMI of Asians is significantly lower than that of the Western population, the appropriate cut-off BMI value and its role in long-term mortality are unclear in Asian patients. Between January 2006 and December 2017, 1215 patients who underwent percutaneous coronary intervention (PCI) for acute STEMI and were alive at discharge (mean age, 67.7 years; male, 75.4%) were evaluated. The cut-off BMI value, which could predict all-cause mortality within 10 years, was detected using a survival classification and regression tree (CART) model. The causes of death according to the BMI value were evaluated in each group. Based on the CART model, the patients were divided into three groups (BMI < 18 kg/m2: 54 patients, 18 kg/m2 ≤ BMI ≤ 20 kg/m2: 109 patients, and BMI > 20 kg/m2: 1052 patients). The BMI decreased with age; with an increased BMI, patients with dyslipidemia, diabetes mellitus, and smoking habit increased. During the study period (median, 4.9 years), 194 patients (26.8%) died (cardiac death, 59 patients; non-cardiac death, 135 patients). All-cause mortality was more frequent as the BMI decreased (BMI < 18 kg/m2; 72.8%, 18 kg/m2 ≤ BMI ≤ 20 kg/m2; 40.5%, and BMI > 20 kg/m2; 22.8%; log-rank p < 0.001). Non-cardiac deaths were more frequent than cardiac deaths in all groups, and the dominance of non-cardiac death was highest in the lowest BMI group. Cut-off BMI values of 18 kg/m2 and 20 kg/m2 can predict long-term mortality after PCI in Asian STEMI survivors, whose cut-off value is lower than that in the Western populations. The main causes of death in this cohort differed according to the BMI values.


Assuntos
Intervenção Coronária Percutânea , Infarto do Miocárdio com Supradesnível do Segmento ST , Idoso , Algoritmos , Povo Asiático , Índice de Massa Corporal , Humanos , Aprendizado de Máquina , Masculino , Intervenção Coronária Percutânea/efeitos adversos , Sistema de Registros , Fatores de Risco , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico , Infarto do Miocárdio com Supradesnível do Segmento ST/cirurgia , Sobreviventes , Resultado do Tratamento
3.
Heart Vessels ; 36(12): 1911-1922, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34081162

RESUMO

Extra-cardiovascular incidental findings (IFs) on preoperative computed tomography (CT) are frequently observed in transcatheter aortic valve implantation (TAVI) candidates. However, the backgrounds of TAVI candidates and comorbidities differ based on the race and/or country, and data on IFs in a specific population are not always applicable to another. The aim of this study was to assess the prevalence, type, and clinical impact of IFs in Japanese TAVI candidates. This was a retrospective, single-center, observational study. CT reports of 257 TAVI candidates were reviewed, and IFs were classified as (a) insignificant: findings that did not require further investigation, treatment, or follow-up; (b) intermediate: findings that needed to be followed up or were considered for further investigation but did not affect the planning of TAVI; and (c) significant: findings that required further investigation immediately or affected the planning of TAVI. At least one IF was found in 254 patients (98.8%). Insignificant, intermediate, and significant IFs were found in 253 (98.4%), 153 (59.5%), and 34 (13.2%) patients, respectively. Newly indicated significant IFs were found in 19 patients (7.4%). In 2 patients (0.8%), TAVI was canceled because of significant IFs. In patients who consequently underwent TAVI, the presence of significant IFs was not associated with the duration from CT performance to TAVI [28 (19-40) days vs. 27 (19-43) days, p = 0.74] and all-cause mortality during the median follow-up period of 413 (223-805) days (p = 0.44). Almost all Japanese TAVI candidates had at least one IF, and the prevalence of significant IFs was not negligible. Although the presence of significant IFs was not associated with mid-term mortality, appropriate management of IFs was considered important.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Humanos , Achados Incidentais , Japão/epidemiologia , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
4.
Medicine (Baltimore) ; 96(50): e9297, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29390391

RESUMO

The usefulness of distal protection devices is still controversial. Moreover, there is no report on thrombus evaluation by using optical coherence tomography (OCT) for determining whether to use a distal protection device. The aim of the present study was to investigate the predictor of filter no-reflow (FNR) by using OCT in primary percutaneous coronary intervention (PCI) for ST-elevated acute myocardial infarction (STEMI).We performed preinterventional OCT in 25 patients with STEMI who were undergoing primary PCI with Filtrap. FNR was defined as coronary flow decreasing to TIMI flow grade 0 after mechanical dilatation.FNR was observed in 13 cases (52%). In the comparisons between cases with or without the FNR, the stent length, lipid pool length, lipid pool + thrombus length, and lipid pool + thrombus index showed significant differences. In multivariate analysis, lipid pool + thrombus length was the only independent predictor of FNR (OR 1.438, 95% CI 1.001 - 2.064, P < .05). The optimal cut-off value of lipid pool + thrombus length for predicting FNR was 13.1 mm (AUC = 0.840, sensitivity 76.9%, specificity 75.0%). Moreover, when adding the evaluation of thrombus length to that of lipid pool length, the prediction accuracy of FNR further increased (IDI 0.14: 0.019-0.25, P = .023).The longitudinal length of the lipid pool plus thrombus was an independent predictor of FNR and the prediction accuracy improved by adding the thrombus to the lipid pool. These results might be useful for making intraoperative judgment about whether filter devices should be applied in primary PCI for STEMI.


Assuntos
Trombose Coronária/diagnóstico por imagem , Lipídeos/análise , Intervenção Coronária Percutânea , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico por imagem , Infarto do Miocárdio com Supradesnível do Segmento ST/cirurgia , Tomografia de Coerência Óptica , Angiografia Coronária , Estudos Transversais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reperfusão Miocárdica , Fenômeno de não Refluxo/diagnóstico por imagem
5.
Circ J ; 79(7): 1542-8, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25818637

RESUMO

BACKGROUND: Until now, there have been few reports on the accuracy of in-stent restenosis (ISR) detection using high-definition computed tomography (HDCT). The purpose of this study was to assess ISR using HDCT with a new gemstone detector and to examine the diagnostic accuracy compared with invasive coronary angiography. METHODS AND RESULTS: We evaluated 162 consecutive patients with 316 stents and the image quality (IQ) scores used to assess ISR, and analyzed whether stent strut thickness and diameter affected IQ score and assessability. In the 316 stents, 278 were diagnosed as assessable with HDCT (88.0%). IQ score for stent diameter ≥3 mm was significantly higher than that for stent diameter <3 mm, for stents with both thick struts ≥140 µm in thickness (mean IQ: 2.04±0.97 vs. 2.83±1.06, P<0.001) and thin struts <140 µm (mean IQ: 1.92±0.87 vs. 2.64±0.96, P=0.01). Assessability for stent diameter ≥3 mm was significantly higher than that for stent diameter <3 mm only for stents with thick struts (92.8% vs. 76.1%, P<0.001). Stent strut thickness, however, was not statistically significantly associated with either IQ score or assessability. CONCLUSIONS: In-stent lumens have high HDCT assessability, and HDCT is useful to evaluate thick-strut stents with diameter <3 mm.


Assuntos
Angiografia Coronária , Oclusão de Enxerto Vascular/diagnóstico por imagem , Stents , Tomografia Computadorizada por Raios X , Idoso , Idoso de 80 Anos ou mais , Angiografia Coronária/instrumentação , Angiografia Coronária/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X/instrumentação , Tomografia Computadorizada por Raios X/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA