Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
1.
Environ Monit Assess ; 194(9): 595, 2022 Jul 20.
Artigo em Inglês | MEDLINE | ID: mdl-35857115

RESUMO

Over the last 10 years, as a possible alternative to the conventional approach to air quality monitoring, real-time monitoring systems that use low-cost sensors and sensor platforms have been frequently applied. Generally, the long-term characteristics of low-cost PM sensors and monitoring have not been thoroughly documented except for a few widely used sensors and monitors. This article addresses the laboratory and field validation of three low-cost PM monitors of the same type that use the NOVA SDS011 PM sensor module over a 1-year period. In outdoor environments, we co-located low-cost PM monitors with GRIMM EDM180 monitors at the National Air Quality Monitoring stations. In indoor environments, we co-located them with a Turnkey Osiris PM monitor. Several performance aspects of the PM monitors were examined: operational data coverage, linearity of response, accuracy, precision, and inter-sensor variability. The obtained results show that inter-monitor R values were typically higher than 0.95 regardless of the environment. The tested monitors demonstrate high linearity in comparison with PM10 and PM2.5 concentrations measured in outdoor air with reference-equivalent instrumentation with R2 values ranging from 0.52 up to 0.83. In addition, very good agreement (R2 values ranging from 0.93 up to 0.97) with the gravimetric PM10 and PM2.5 method is obtained in the indoor environment (30 < RH < 70%). High RH (over 70%) negatively affected the PM monitors' response, especially in the case of PM10 concentrations (high overestimation).


Assuntos
Poluentes Atmosféricos , Poluição do Ar , Poluentes Atmosféricos/análise , Poluição do Ar/análise , Monitoramento Ambiental/métodos , Laboratórios , Material Particulado/análise
2.
Epidemiol Prev ; 42(5-6S1): 21-36, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30322233

RESUMO

BACKGROUND: this paper is based upon work from COST Action ICSHNet. Health risks related to living close to industrially contaminated sites (ICSs) are a public concern. Toxicology-based risk assessment of single contaminants is the main approach to assess health risks, but epidemiological studies which investigate the relationships between exposure and health directly in the affected population have contributed important evidence. Limitations in exposure assessment have substantially contributed to uncertainty about associations found in epidemiological studies. OBJECTIVES: to examine exposure assessment methods that have been used in epidemiological studies on ICSs and to provide recommendations for improved exposure assessment in epidemiological studies by comparing exposure assessment methods in epidemiological studies and risk assessments. METHODS: after defining the multi-media framework of exposure related to ICSs, we discussed selected multi-media models applied in Europe. We provided an overview of exposure assessment in 54 epidemiological studies from a systematic review of hazardous waste sites; a systematic review of 41 epidemiological studies on incinerators and 52 additional studies on ICSs and health identified for this review. RESULTS: we identified 10 multi-media models used in Europe primarily for risk assessment. Recent models incorporated estimation of internal biomarker levels. Predictions of the models differ particularly for the routes 'indoor air inhalation' and 'vegetable consumption'. Virtually all of the 54 hazardous waste studies used proximity indicators of exposure, based on municipality or zip code of residence (28 studies) or distance to a contaminated site (25 studies). One study used human biomonitoring. In virtually all epidemiological studies, actual land use was ignored. In the 52 additional studies on contaminated sites, proximity indicators were applied in 39 studies, air pollution dispersion modelling in 6 studies, and human biomonitoring in 9 studies. Exposure assessment in epidemiological studies on incinerators included indicators (presence of source in municipality and distance to the incinerator) and air dispersion modelling. Environmental multi-media modelling methods were not applied in any of the three groups of studies. CONCLUSIONS: recommendations for refined exposure assessment in epidemiological studies included the use of more sophisticated exposure metrics instead of simple proximity indicators where feasible, as distance from a source results in misclassification of exposure as it ignores key determinants of environmental fate and transport, source characteristics, land use, and human consumption behaviour. More validation studies using personal exposure or human biomonitoring are needed to assess misclassification of exposure. Exposure assessment should take more advantage of the detailed multi-media exposure assessment procedures developed for risk assessment. The use of indicators can be substantially improved by linking definition of zones of exposure to existing knowledge of extent of dispersion. Studies should incorporate more often land use and individual behaviour.


Assuntos
Exposição Ambiental , Poluição Ambiental , Estudos Epidemiológicos , Indústrias , Monitoramento Ambiental , Guias como Assunto , Humanos , Modelos Teóricos , Medição de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA