1.
Cleft Palate Craniofac J ; 60(5): 601-607, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-35234078

RESUMO

OBJECTIVE: To evaluate the reproducibility and accuracy of a new, easy-to-use volumetric assessment of the alveolar cleft. DESIGN: Twelve cone-beam computed tomography (CBCT) datasets of patients with a unilateral cleft lip, alveolus, and palate were evaluated by two investigators. Residual alveolar cleft calcified volume one year after surgery was analyzed by using standardized landmarks to determine the borders of the cleft defect and semi-automatically segment the alveolar cleft defect. RESULTS: The Dice-coefficient between observers for the segmented preoperative alveolar cleft defect was 0.81. Average percentage of residual alveolar cleft calcified material was 66.7% one year postoperatively. CONCLUSIONS: This study demonstrates a reliable and practical semi-automatic three-dimensional volumetric assessment method for unilateral clefts using CBCT.


Assuntos
Enxerto de Osso Alveolar , Fenda Labial , Fissura Palatina , Humanos , Enxerto de Osso Alveolar/métodos , Reprodutibilidade dos Testes , Fissura Palatina/diagnóstico por imagem , Fissura Palatina/cirurgia , Fenda Labial/diagnóstico por imagem , Fenda Labial/cirurgia , Tomografia Computadorizada de Feixe Cônico/métodos
2.
Sci Rep ; 7(1): 16263, 2017 11 24.
Artigo em Inglês | MEDLINE | ID: mdl-29176666

RESUMO

The RealSense F200 represents a new generation of economically viable 4-dimensional imaging (4D) systems for home use. However, its 3D geometric (depth) accuracy has not been clinically tested. Therefore, this study determined the depth accuracy of the RealSense, in a cohort of patients with a unilateral facial palsy (n = 34), by using the clinically validated 3dMD system as a gold standard. The patients were simultaneously recorded with both systems, capturing six Sunnybrook poses. This study has shown that the RealSense depth accuracy was not affected by a facial palsy (1.48 ± 0.28 mm), compared to a healthy face (1.46 ± 0.26 mm). Furthermore, the Sunnybrook poses did not influence the RealSense depth accuracy (p = 0.76). However, the distance of the patients to the RealSense was shown to affect the accuracy of the system, where the highest depth accuracy of 1.07 mm was measured at a distance of 35 cm. Overall, this study has shown that the RealSense can provide reliable and accurate depth data when recording a range of facial movements. Therefore, when the portability, low-costs, and availability of the RealSense are taken into consideration, the camera is a viable option for 4D close range imaging in telehealth.


Assuntos
Face/diagnóstico por imagem , Paralisia Facial/diagnóstico por imagem , Humanos , Imageamento Tridimensional