Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Bases de dados
Tipo de documento
Intervalo de ano de publicação
2.
Transfusion ; 61(9): 2658-2667, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34216156

RESUMO

BACKGROUND: The COVID-19 pandemic has been accompanied by the largest mobilization of therapeutic convalescent plasma (CCP) in over a century. Initial identification of high titer units was based on dose-response data using the Ortho VITROS IgG assay. The proliferation of severe acute respiratory syndrome coronavirus 2 serological assays and non-uniform application has led to uncertainty about their interrelationships. The purpose of this study was to establish correlations and analogous cutoffs between multiple serological assays. METHODS: We compared the Ortho, Abbott, Roche, an anti-spike (S) ELISA, and a virus neutralization assay. Relationships relative to FDA-approved cutoffs under the CCP emergency use authorization were identified in convalescent plasma from a cohort of 79 donors from April 2020. RESULTS: Relative to the neutralization assay, the spearman r value of the Ortho Clinical, Abbott, Roche, anti-S ELISA assays was 0.65, 0.59, 0.45, and 0.76, respectively. The best correlative index for establishing high-titer units was 3.87 signal-to-cutoff (S/C) for the Abbott, 13.82 cutoff index for the Roche, 1:1412 for the anti-S ELISA, 1:219 by the neutralization assay, and 15.9 S/C by the Ortho Clinical assay. The overall agreement using derived cutoffs compared to a neutralizing titer of 1:250 was 78.5% for Abbott, 74.7% for Roche, 83.5% for the anti-S ELISA, and 78.5% for Ortho Clinical. DISCUSSION: Assays based on antibodies against the nucleoprotein were positively associated with neutralizing titers and the Ortho assay, although their ability to distinguish FDA high-titer specimens was imperfect. The resulting relationships help reconcile results from the large body of serological data generated during the COVID-19 pandemic.


Assuntos
Anticorpos Antivirais/imunologia , COVID-19/epidemiologia , COVID-19/imunologia , SARS-CoV-2/imunologia , Adulto , Idoso , Anticorpos Neutralizantes/sangue , Anticorpos Neutralizantes/imunologia , Anticorpos Antivirais/sangue , COVID-19/sangue , COVID-19/terapia , Teste Sorológico para COVID-19 , Comorbidade , Ensaio de Imunoadsorção Enzimática , Feminino , Humanos , Imunização Passiva , Imunoglobulina G/sangue , Imunoglobulina G/imunologia , Masculino , Pessoa de Meia-Idade , Curva ROC , Estudos Soroepidemiológicos , Adulto Jovem , Soroterapia para COVID-19
3.
medRxiv ; 2021 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-33791711

RESUMO

The COVID-19 pandemic has been accompanied by the largest mobilization of therapeutic convalescent plasma (CCP) in over a century. Initial identification of high titer units was based on dose-response data using the Ortho VITROS IgG assay. The proliferation of SARS-CoV-2 serological assays and non-uniform application has led to uncertainty about their interrelationships. The purpose of this study was to establish correlations and analogous cutoffs between commercially available serological tests (Ortho, Abbott, Roche), a spike ELISA, and a virus neutralization assay using convalescent plasma from a cohort of 79 donors from April 2020. Relationships relative to FDA-approved cutoffs under the CCP EUA were identified by linear regression and receiver operator characteristic curves. Relative to the Ortho VITROS assay, the r2 of the Abbott, Roche, the anti-Spike ELISA and the neutralizing assay were 0.58, 0.5, 0.82, and 0.44, respectively. The best correlative index for establishing high-titer units was 3.82 S/C for the Abbott, 10.89 COI for the Roche, 1:1,202 for the anti-Spike ELISA, and 1:200 by the neutralization assay. The overall agreement using derived cutoffs compared to the CCP EUA Ortho VITROS cutoff of 9.5 was 92.4% for Abbott, 84.8% for Roche, 87.3% for the anti-S ELISA and 78.5% for the neutralization assay. Assays based on antibodies against the nucleoprotein (Roche, Abbott) and neutralizing antibody tests were positively associated with the Ortho assay, although their ability to distinguish FDA high-titer specimens was imperfect. The resulting relationships help reconcile results from the large body of serological data generated during the COVID-19 pandemic.

4.
Clin Lab Med ; 40(4): 521-533, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-33121620

RESUMO

Formal medical and public health microbiology (MPHM) fellowship programs play a key role in preparing future clinical microbiology laboratory directors for their leadership and management responsibilities. Given the continually evolving MPHM field, fellowships must remain adaptable to changes in the field, providing trainees with the opportunity to engage with newly emerging diagnostic modalities, while continuing to emphasize the "bread and butter" techniques of clinical microbiology. This article discusses the key components of a fellowship program and provides recommendations for incorporating educational best practices.


Assuntos
Bolsas de Estudo , Laboratórios/organização & administração , Ciência de Laboratório Médico , Microbiologia , Humanos , Ciência de Laboratório Médico/educação , Ciência de Laboratório Médico/organização & administração , Microbiologia/educação , Microbiologia/organização & administração
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA