Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
IEEE Trans Biomed Eng ; 60(11): 3131-40, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23782791

RESUMO

Accurate measurement of knee kinematics during functional activities suffers mainly from soft tissue artifact (STA): the combination of local surface deformations and rigid movement of markers relative to the underlying bone (also called rigid STA movement: RSTAM). This study proposes to assess RSTAM on the thigh, shank, and knee joint and to observe possible features between subjects. Nineteen subjects with knee arthroplasty were asked to walk on a treadmill while a biplane fluoroscopic system (X-rays) and a stereophotogrammetric system (skin markers) recorded their knee movement. The RSTAM was defined as the rigid movement of the cluster of skin markers relative to the prosthesis. The results showed that RSTAM amplitude represents approximately 80-100% of the STA. The vertical axis of the anatomical frame of the femur was influenced the most by RSTAM. Combined with tibial error, internal/external rotation angle and distraction-compression were the knee kinematics parameters most affected by RSTAM during the gait cycle, with average rms values of 3.8° and 11.1 mm. This study highlighted higher RSTAM during the swing phase particularly in the thigh segment and suggests new features for RSTAM such as the particular shape of some RSTAM waveforms and the absence of RSTAM in certain kinematics during the gait phases. The comparison of coefficient of multiple correlations showed some similarities of RSTAM between subjects, while some correlations were found with gait speed and BMI. These new insights could potentially allow the development of new methods of compensation to avoid STA.


Assuntos
Artroplastia do Joelho , Fenômenos Biomecânicos/fisiologia , Articulação do Joelho , Caminhada/fisiologia , Idoso , Artefatos , Feminino , Marcadores Fiduciais , Fluoroscopia/instrumentação , Fluoroscopia/métodos , Marcha/fisiologia , Humanos , Articulação do Joelho/anatomia & histologia , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/fisiologia , Masculino , Pessoa de Meia-Idade , Fotogrametria , Processamento de Sinais Assistido por Computador
2.
Eur Spine J ; 21 Suppl 6: S760-4, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21656052

RESUMO

INTRODUCTION: Lumbar spinal stenosis (LSS) treatment is based primarily on the clinical criteria providing that imaging confirms radiological stenosis. The radiological measurement more commonly used is the dural sac cross-sectional area (DSCA). It has been recently shown that grading stenosis based on the morphology of the dural sac as seen on axial T2 MRI images, better reflects severity of stenosis than DSCA and is of prognostic value. This radiological prospective study investigates the variability of surface measurements and morphological grading of stenosis for varying degrees of angulation of the T2 axial images relative to the disc space as observed in clinical practice. MATERIALS AND METHODS: Lumbar spine TSE T2 three-dimensional (3D) MRI sequences were obtained from 32 consecutive patients presenting with either suspected spinal stenosis or low back pain. Axial reconstructions using the OsiriX software at 0°, 10°, 20° and 30° relative to the disc space orientation were obtained for a total of 97 levels. For each level, DSCA was digitally measured and stenosis was graded according to the 4-point (A-D) morphological grading by two observers. RESULTS: A good interobserver agreement was found in grade evaluation of stenosis (k = 0.71). DSCA varied significantly as the slice orientation increased from 0° to +10°, +20° and +30° at each level examined (P < 0.0001) (-15 to +32% at 10°, -24 to +143% at 20° and -29 to +231% at 30° of slice orientation). Stenosis definition based on the surface measurements changed in 39 out of the 97 levels studied, whereas the morphology grade was modified only in two levels (P < 0.01). DISCUSSION: The need to obtain continuous slices using the classical 2D MRI acquisition technique entails often at least a 10° slice inclination relative to one of the studied discs. Even at this low angulation, we found a significantly statistical difference between surface changes and morphological grading change. In clinical practice, given the above findings, it might therefore not be necessary to align the axial cuts to each individual disc level which could be more time-consuming than obtaining a single series of axial cuts perpendicular to the middle of the lumbar spine or to the most stenotic level. In conclusion, morphological grading seems to offer an alternative means of assessing severity of spinal stenosis that is little affected by image acquisition technique.


Assuntos
Imageamento por Ressonância Magnética/métodos , Índice de Gravidade de Doença , Estenose Espinal/diagnóstico por imagem , Estenose Espinal/patologia , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Estudos Prospectivos , Radiografia , Reprodutibilidade dos Testes , Estudos Retrospectivos
3.
Eur Spine J ; 16(5): 613-7, 2007 May.
Artigo em Inglês | MEDLINE | ID: mdl-16967297

RESUMO

Percutaneous insertion of cannulated pedicle screws has been recently developed as a minimally invasive alternative to the open technique during instrumented fusion procedures. Given the reported rate of screw misplacement using open techniques (up to 40%), we considered it important to analyze possible side effects of this new technique. Placement of 60 pedicle screws in 15 consecutive patients undergoing lumbar or lumbosacral fusion, mainly for spondylolisthesis, were analyzed. Axial, coronal, and sagittal reformatted computer tomography images were examined by three observers. Individual and consensus interpretation was obtained for each screw position. Along with frank penetration, we also looked at cortical encroachment of the pedicular wall by the screw. Thirteen percent of the patients (2/15) had severe frank penetration from the screws, while 80% of them (12/15) had some perforation. On axial images the incidence of severe frank pedicle penetration was 3.3% while the overall rate of screw perforation was 23%. In coronal images the overall screw perforation rate rose to 30% while the rate of severe frank pedicle penetration remained unchanged. One patient (6.6%) suffered S1 root symptoms due to a frankly medially misplaced screw, requiring re-operation. This study has shown that percutaneous insertion of cannulated pedicle screws in the lumbar spine is an acceptable procedure. The overall rate of perforation in axial images is below the higher rates reported in the literature but does remain important. Frank penetration of the pedicle was nevertheless low. It remains a demanding technique and has to be performed with extreme care to detail.


Assuntos
Parafusos Ósseos , Complicações Pós-Operatórias/diagnóstico por imagem , Fusão Vertebral/instrumentação , Espondilolistese/diagnóstico por imagem , Espondilolistese/cirurgia , Tomografia Computadorizada por Raios X/estatística & dados numéricos , Humanos , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/cirurgia , Procedimentos Cirúrgicos Minimamente Invasivos , Variações Dependentes do Observador , Fusão Vertebral/efeitos adversos
4.
Radiology ; 227(3): 681-9, 2003 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-12702827

RESUMO

PURPOSE: To determine if multi-detector row computed tomography (CT) can replace conventional radiography and be performed alone in severe trauma patients for the depiction of thoracolumbar spine fractures. MATERIALS AND METHODS: One hundred consecutive severe trauma patients who underwent conventional radiography of the thoracolumbar spine as well as thoracoabdominal multi-detector row CT were prospectively identified. Conventional radiographs were reviewed independently by three radiologists and two orthopedic surgeons; CT images were reviewed by three radiologists. Reviewers were blinded both to one another's reviews and to the results of initial evaluation. Presence, location, and stability of fractures, as well as quality of reviewed images, were assessed. Statistical analysis was performed to determine sensitivity and interobserver agreement for each procedure, with results of clinical and radiologic follow-up as the standard of reference. The time to perform each examination and the radiation dose involved were evaluated. A resource cost analysis was performed. RESULTS: Sixty-seven fractured vertebrae were diagnosed in 26 patients. Twelve patients had unstable spine fractures. Mean sensitivity and interobserver agreement, respectively, for detection of unstable fractures were 97.2% and 0.951 for multi-detector row CT and 33.3% and 0.368 for conventional radiography. The median times to perform a conventional radiographic and a multi-detector row CT examination, respectively, were 33 and 40 minutes. Effective radiation doses at conventional radiography of the spine and thoracoabdominal multi-detector row CT, respectively, were 6.36 mSv and 19.42 mSv. Multi-detector row CT enabled identification of 146 associated traumatic lesions. The costs of conventional radiography and multi-detector row CT, respectively, were 145 and 880 US dollars per patient. CONCLUSION: Multi-detector row CT is a better examination for depicting spine fractures than conventional radiography. It can replace conventional radiography and be performed alone in patients who have sustained severe trauma.


Assuntos
Vértebras Lombares/lesões , Fraturas da Coluna Vertebral/diagnóstico por imagem , Vértebras Torácicas/lesões , Tomografia Computadorizada por Raios X/métodos , Adulto , Custos e Análise de Custo , Feminino , Humanos , Masculino , Variações Dependentes do Observador , Doses de Radiação , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X/economia
5.
Radiology ; 222(3): 763-70, 2002 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-11867798

RESUMO

PURPOSE: To evaluate magnetic resonance (MR) imaging and MR arthrographic findings in the pisotriquetral joint (PTJ) and their contribution to assessment of PTJ osteoarthritis. MATERIALS AND METHODS: Images of 22 fresh human cadaveric PTJs were obtained with both conventional and arthrographic MR techniques. The MR appearances of all intraarticular and periarticular structures were analyzed and correlated with anatomic slices. Two readers graded visibility of anatomic structures and severity of joint abnormalities. Differences in the visibility ratings at standard MR imaging and at MR arthrography were calculated. Association between the type of pisiform insertion of ligament or muscle with cartilaginous abnormalities of the PTJ was assessed. The association between cartilaginous lesions and osteoarthritic changes was calculated. RESULTS: The tendon sheath, the fibrous capsule, and cartilaginous surfaces were better visualized at MR arthrography than at MR imaging. Pisohamate and pisometacarpal ligaments were slightly better seen on MR arthrograms. Tendons, muscles, and retinacular structures were well demonstrated at both conventional MR and MR arthrography. Cartilaginous lesions and osteophytes were easily identified and were detected more often in the pisiform bone than in the triquetral bone. Communication of the PTJ with the radiocarpal joint was noted in 18 (82%) of 22 wrists. CONCLUSION: MR imaging and/or MR arthrography allows visualization of all anatomic structures of the PTJ. MR arthrography improves visualization of findings of osteoarthritis.


Assuntos
Imageamento por Ressonância Magnética , Articulação do Punho/anatomia & histologia , Idoso , Idoso de 80 Anos ou mais , Ossos do Carpo/anatomia & histologia , Feminino , Humanos , Técnicas In Vitro , Ligamentos Articulares/anatomia & histologia , Masculino , Pessoa de Meia-Idade , Tendões/anatomia & histologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA