RESUMO
BACKGROUND: High resolution 3D T1 mapping is important for assessment of diffuse myocardial fibrosis in left atrium or other thin-walled structures. In this work, we investigated a fast single-TI 3D high resolution T1 mapping method that directly transforms a 3D late gadolinium enhancement (LGE) volume to a 3D T1 map. METHODS: The proposed method, T1-refBlochi, is based on Bloch equation modeling of the LGE signal, a single-point calibration, and assumptions that proton density and T2* are relatively uniform in the heart. Several sources of error of this method were analyzed mathematically and with simulations. Imaging was performed in phantoms, eight swine and five patients, comparing T1-refBlochi to a standard spin-echo T1 mapping, 3D multi-TI T1 mapping, and 2D ShMOLLI, respectively. RESULTS: The method has a good accuracy and adequate precision, even considering various sources of error. In phantoms, over a range of protocols, heart-rates and T1 s, the bias ±1SD was -3 ms ± 9 ms. The porcine studies showed excellent agreement between T1-refBlochi and the multi-TI method (bias ±1SD = -6 ± 22 ms). The proton density and T2* weightings yielded ratios for scar/blood of 0.94 ± 0.01 and for myocardium/blood of 1.03 ± 0.02 in the eight swine, confirming that sufficient uniformity of proton density and T2* weightings exists among heterogeneous tissues of the heart. In the patients, the mean T1 bias ±1SD in myocardium and blood between T1-refBlochi and ShMOLLI was -9 ms ± 21 ms. CONCLUSION: T1-refBlochi provides a fast single-TI high resolution 3D T1 map of the heart with good accuracy and adequate precision.
Assuntos
Cardiomiopatias/diagnóstico por imagem , Meios de Contraste/administração & dosagem , Átrios do Coração/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Compostos Organometálicos/administração & dosagem , Algoritmos , Animais , Cardiomiopatias/patologia , Simulação por Computador , Estudos de Viabilidade , Feminino , Fibrose , Átrios do Coração/patologia , Humanos , Imageamento por Ressonância Magnética/instrumentação , Masculino , Pessoa de Meia-Idade , Modelos Cardiovasculares , Método de Monte Carlo , Imagens de Fantasmas , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Sus scrofaRESUMO
PURPOSE: The energy spectrum for a cadmium zinc telluride (CZT) detector has a low energy tail due to incomplete charge collection and intercrystal scattering. Due to these solid-state detector effects, scatter would be overestimated if the conventional triple-energy window (TEW) method is used for scatter and crosstalk corrections in CZT-based imaging systems. The objective of this work is to develop a scatter and crosstalk correction method for (99m)Tc/(123)I dual-radionuclide imaging for a CZT-based dedicated cardiac SPECT system with pinhole collimators (GE Discovery NM 530c/570c). METHODS: A tailing model was developed to account for the low energy tail effects of the CZT detector. The parameters of the model were obtained using (99m)Tc and (123)I point source measurements. A scatter model was defined to characterize the relationship between down-scatter and self-scatter projections. The parameters for this model were obtained from Monte Carlo simulation using SIMIND. The tailing and scatter models were further incorporated into a projection count model, and the primary and self-scatter projections of each radionuclide were determined with a maximum likelihood expectation maximization (MLEM) iterative estimation approach. The extracted scatter and crosstalk projections were then incorporated into MLEM image reconstruction as an additive term in forward projection to obtain scatter- and crosstalk-corrected images. The proposed method was validated using Monte Carlo simulation, line source experiment, anthropomorphic torso phantom studies, and patient studies. The performance of the proposed method was also compared to that obtained with the conventional TEW method. RESULTS: Monte Carlo simulations and line source experiment demonstrated that the TEW method overestimated scatter while their proposed method provided more accurate scatter estimation by considering the low energy tail effect. In the phantom study, improved defect contrasts were observed with both correction methods compared to no correction, especially for the images of (99m)Tc in dual-radionuclide imaging where there is heavy contamination from (123)I. In this case, the nontransmural defect contrast was improved from 0.39 to 0.47 with the TEW method and to 0.51 with their proposed method and the transmural defect contrast was improved from 0.62 to 0.74 with the TEW method and to 0.73 with their proposed method. In the patient study, the proposed method provided higher myocardium-to-blood pool contrast than that of the TEW method. Similar to the phantom experiment, the improvement was the most substantial for the images of (99m)Tc in dual-radionuclide imaging. In this case, the myocardium-to-blood pool ratio was improved from 7.0 to 38.3 with the TEW method and to 63.6 with their proposed method. Compared to the TEW method, the proposed method also provided higher count levels in the reconstructed images in both phantom and patient studies, indicating reduced overestimation of scatter. Using the proposed method, consistent reconstruction results were obtained for both single-radionuclide data with scatter correction and dual-radionuclide data with scatter and crosstalk corrections, in both phantom and human studies. CONCLUSIONS: The authors demonstrate that the TEW method leads to overestimation in scatter and crosstalk for the CZT-based imaging system while the proposed scatter and crosstalk correction method can provide more accurate self-scatter and down-scatter estimations for quantitative single-radionuclide and dual-radionuclide imaging.
Assuntos
Cádmio , Radioisótopos do Iodo , Compostos Radiofarmacêuticos , Tecnécio , Telúrio , Tomografia Computadorizada de Emissão de Fóton Único/instrumentação , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Zinco , Simulação por Computador , Coração/diagnóstico por imagem , Humanos , Funções Verossimilhança , Modelos Biológicos , Método de Monte Carlo , Imagens de Fantasmas , Fótons , Espalhamento de Radiação , Tomografia Computadorizada por Raios XRESUMO
This study evaluated the effectiveness of the Smoking Cessation and Reduction in Pregnancy Treatment (SCRIPT) Program selected by the West Virginia-Right From The Start Project for state-wide dissemination. A process evaluation documented the fidelity of SCRIPT delivery by Designated Care Coordinators (DCC), licensed nurses and social workers who provide home-based case management to Medicaid-eligible clients in all 55 counties. We implemented a quasi-experimental, non-randomized, matched Comparison (C) Group design. The SCRIPT Experimental E Group (N = 259) were all clients in 2009-2010 that wanted to quit, provided a screening carbon monoxide (CO), and received a SCRIPT home visit. The (C) Group was derived from all clients in 2006-2007 who had the same CO assessments as E Group clients and reported receiving cessation counseling. We stratified the baseline CO of E Group clients into 10 strata, and randomly selected the same number of (C) Group clients (N = 259) from each matched strata to evaluate the effectiveness of the SCRIPT Program. There were no significant baseline differences in the E and (C) Group. A Process Evaluation documented a significant increase in the fidelity of DCC delivery of SCRIPT Program procedures: from 63 % in 2006 to 74 % in 2010. Significant increases were documented in the E Group cessation rate (+9.3 %) and significant reduction rate (+4.5 %), a ≥50 % reduction from a baseline CO. Perinatal health case management staff can deliver the SCRIPT Program, and Medicaid-supported clients can change smoking behavior, even very late in pregnancy. When multiple biases were analyzed, we concluded the SCRIPT Dissemination Project was the most plausible reason for the significant changes in behavior.
Assuntos
Cuidado Pré-Natal/organização & administração , Abandono do Hábito de Fumar/métodos , Prevenção do Hábito de Fumar , Biomarcadores/análise , Dióxido de Carbono/análise , Cotinina/análise , Aconselhamento/métodos , Feminino , Visita Domiciliar , Humanos , Medicaid , Gravidez , Cuidado Pré-Natal/métodos , Cuidado Pré-Natal/estatística & dados numéricos , Avaliação de Programas e Projetos de Saúde , Fumar/epidemiologia , Fumar/metabolismo , Abandono do Hábito de Fumar/estatística & dados numéricos , Estados Unidos , West Virginia/epidemiologiaRESUMO
BACKGROUND: The PRKAG2 cardiac syndrome is an inherited metabolic disease of the heart characterized by excessive myocardial glycogen deposition. The biochemical alterations associated with this condition remain controversial and have not previously been studied in affected humans. METHODS AND RESULTS: Positron emission tomography (PET) imaging was used to quantitatively assess myocardial glucose uptake (MGU) in 6 adult subjects with the PRKAG2 cardiac syndrome and 6 healthy, matched control subjects using the glucose analogue (18)F-Fluoro-2-deoxyglucose (FDG). Studies were performed under a euglycemic hyperinsulinemic clamp to ensure stable blood glucose levels. Rubidium-82 perfusion scans were performed to ensure that myocardial differences in myocardial glucose uptake were not the result of significant myocardial scar. In adult patients with phenotypic expression of disease, the median myocardial glucose uptake of the left ventricle was 0.18 mumol/min/g (interquartile range, 0.14, 0.24), compared with 0.40 mumol/min/g (interquartile range, 0.30 to 0.45) in the control group (P=0.01). The median blood glucose during FDG-PET imaging was 4.72 mmol/L (interquartile range, 4.32 to 4.97) in the PRKAG2 group and 4.38 mmol/L (interquartile range, 3.90, 4.79) in the control group (P=NS). The significant decrease observed in myocardial glucose uptake in affected patients occurred in the absence of significant myocardial scar. CONCLUSIONS: The PRKAG2 cardiac syndrome is associated with a reduction of glucose uptake in adult patients affected with this genetic condition. In this pilot study, (18)F-FDG-PET imaging is a useful tool to assess alterations in myocardial glucose transport in this inherited metabolic disease and provide insight into the biochemical pathophysiology of the diseased state.