Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros

País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Nat Commun ; 15(1): 3650, 2024 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-38688925

RESUMO

Utilization of digital technologies for cataract screening in primary care is a potential solution for addressing the dilemma between the growing aging population and unequally distributed resources. Here, we propose a digital technology-driven hierarchical screening (DH screening) pattern implemented in China to promote the equity and accessibility of healthcare. It consists of home-based mobile artificial intelligence (AI) screening, community-based AI diagnosis, and referral to hospitals. We utilize decision-analytic Markov models to evaluate the cost-effectiveness and cost-utility of different cataract screening strategies (no screening, telescreening, AI screening and DH screening). A simulated cohort of 100,000 individuals from age 50 is built through a total of 30 1-year Markov cycles. The primary outcomes are incremental cost-effectiveness ratio and incremental cost-utility ratio. The results show that DH screening dominates no screening, telescreening and AI screening in urban and rural China. Annual DH screening emerges as the most economically effective strategy with 341 (338 to 344) and 1326 (1312 to 1340) years of blindness avoided compared with telescreening, and 37 (35 to 39) and 140 (131 to 148) years compared with AI screening in urban and rural settings, respectively. The findings remain robust across all sensitivity analyses conducted. Here, we report that DH screening is cost-effective in urban and rural China, and the annual screening proves to be the most cost-effective option, providing an economic rationale for policymakers promoting public eye health in low- and middle-income countries.


Assuntos
Catarata , Análise Custo-Benefício , Programas de Rastreamento , Humanos , China/epidemiologia , Catarata/economia , Catarata/diagnóstico , Catarata/epidemiologia , Pessoa de Meia-Idade , Programas de Rastreamento/economia , Programas de Rastreamento/métodos , Masculino , Tecnologia Digital/economia , Feminino , Cadeias de Markov , Idoso , Inteligência Artificial , Telemedicina/economia , Telemedicina/métodos
2.
Arq. bras. oftalmol ; 86(4): 322-329, July-Sep. 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1447374

RESUMO

ABSTRACT Purpose: This study aimed to use computational models for simulating the movement of respiratory droplets when assessing the efficacy of standard slit-lamp shield versus a new shield designed for increased clinician comfort as well as adequate protection. Methods: Simulations were performed using the commercial software Star-CCM+. Respiratory droplets were assumed to be 100% water in volume fraction with particle diameter distribution represented by a geometric mean of 74.4 (±1.5 standard deviation) μm over a 4-min duration. The total mass of respiratory droplets expelled from patients' mouths and droplet accumulation on the manikin were measured under the following three conditions: with no slit-lamp shield, using the standard slit-lamp shield, and using our new proposed shield. Results: The total accumulated water droplet mass (kilogram) and percentage of expelled mass accumulated on the shield under the three aforementioned conditions were as follows: 5.84e-10 kg (28% of the total weight of particle emitted that settled on the manikin), 9.14e-13 kg (0.045%), and 3.19e-13 (0.015%), respectively. The standard shield could shield off 99.83% of the particles that would otherwise be deposited on the manikin, which is comparable to 99.95% for the proposed design. Conclusion: Slit-lamp shields are effective infection control tools against respiratory droplets. The proposed shield showed comparable effectiveness compared with conventional slit-lamp shields, but with potentially enhanced ergonomics for ophthalmologists during slit-lamp examinations.


RESUMO Introdução: Os oftalmologistas têm alto risco de contrair a doença do Coronavírus-19 devido à proximidade com os pacientes durante os exames com lâmpada de fenda. Usamos um modelo de computação para avaliar a eficácia das proteções para lâmpadas de fenda e propusemos uma nova proteção ergonomicamente projetada. Métodos: As simulações foram realizadas no software comercial Star-CCM +. Os aerossóis de gotículas foram considerados 100% de água em fração de volume com distribuição de diâmetro de partícula representada por uma média geométrica de 74,4 ± 1,5 (desvio padrão) μm ao longo de uma duração de quatro minutos. A massa total de gotículas de água acumulada no manequim e a massa expelida pela boca do paciente foram medidas em três condições diferentes: 1) Sem protetor de lâmpada de fenda, 2) com protetor padrão, 3) Com o novo protetor proposto. Resultados: A massa total acumulada das gotas de água (kg) e a porcentagem da massa expelida acumulada no escudo para cada uma das respectivas condições foram; 1) 5,84e-10 kg (28% do peso total da partícula emitida que assentou no manequim), 2) 9,14e-13 kg (0,045%), 3,19e-13 (0,015%). O escudo padrão foi capaz de proteger 99,83% das partículas que, de outra forma, teriam se depositado no manequim, o que é semelhante a 99,95% para o projeto proposto. Conclusão: Protetores com lâmpada de fenda são ferramentas eficazes de controle de infecção contra gotículas respiratórias. O protetor proposto mostrou eficácia comparável em comparação com os protetores de lâmpada de fenda convencionais, mas potencialmente oferece uma melhor ergonomia para oftalmologistas durante o exame de lâmpada de fenda.

4.
Arq Bras Oftalmol ; 86(4): 322-329, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-35544928

RESUMO

PURPOSE: This study aimed to use computational models for simulating the movement of respiratory droplets when assessing the efficacy of standard slit-lamp shield versus a new shield designed for increased clinician comfort as well as adequate protection. METHODS: Simulations were performed using the commercial software Star-CCM+. Respiratory droplets were assumed to be 100% water in volume fraction with particle diameter distribution represented by a geometric mean of 74.4 (±1.5 standard deviation) µm over a 4-min duration. The total mass of respiratory droplets expelled from patients' mouths and droplet accumulation on the manikin were measured under the following three conditions: with no slit-lamp shield, using the standard slit-lamp shield, and using our new proposed shield. RESULTS: The total accumulated water droplet mass (kilogram) and percentage of expelled mass accumulated on the shield under the three aforementioned conditions were as follows: 5.84e-10 kg (28% of the total weight of particle emitted that settled on the manikin), 9.14e-13 kg (0.045%), and 3.19e-13 (0.015%), respectively. The standard shield could shield off 99.83% of the particles that would otherwise be deposited on the manikin, which is comparable to 99.95% for the proposed design. Conclusion: Slit-lamp shields are effective infection control tools against respiratory droplets. The proposed shield showed comparable effectiveness compared with conventional slit-lamp shields, but with potentially enhanced ergonomics for ophthalmologists during slit-lamp examinations.

7.
Ophthalmology ; 128(11): 1580-1591, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-33940045

RESUMO

TOPIC: To provide updated estimates on the global prevalence and number of people with diabetic retinopathy (DR) through 2045. CLINICAL RELEVANCE: The International Diabetes Federation (IDF) estimated the global population with diabetes mellitus (DM) to be 463 million in 2019 and 700 million in 2045. Diabetic retinopathy remains a common complication of DM and a leading cause of preventable blindness in the adult working population. METHODS: We conducted a systematic review using PubMed, Medline, Web of Science, and Scopus for population-based studies published up to March 2020. Random effect meta-analysis with logit transformation was performed to estimate global and regional prevalence of DR, vision-threatening DR (VTDR), and clinically significant macular edema (CSME). Projections of DR, VTDR, and CSME burden were based on population data from the IDF Atlas 2019. RESULTS: We included 59 population-based studies. Among individuals with diabetes, global prevalence was 22.27% (95% confidence interval [CI], 19.73%-25.03%) for DR, 6.17% (95% CI, 5.43%-6.98%) for VTDR, and 4.07% (95% CI, 3.42%-4.82%) for CSME. In 2020, the number of adults worldwide with DR, VTDR, and CSME was estimated to be 103.12 million, 28.54 million, and 18.83 million, respectively; by 2045, the numbers are projected to increase to 160.50 million, 44.82 million, and 28.61 million, respectively. Diabetic retinopathy prevalence was highest in Africa (35.90%) and North American and the Caribbean (33.30%) and was lowest in South and Central America (13.37%). In meta-regression models adjusting for habitation type, response rate, study year, and DR diagnostic method, Hispanics (odds ratio [OR], 2.92; 95% CI, 1.22-6.98) and Middle Easterners (OR, 2.44; 95% CI, 1.51-3.94) with diabetes were more likely to have DR compared with Asians. DISCUSSION: The global DR burden is expected to remain high through 2045, disproportionately affecting countries in the Middle East and North Africa and the Western Pacific. These updated estimates may guide DR screening, treatment, and public health care strategies.


Assuntos
Efeitos Psicossociais da Doença , Retinopatia Diabética/epidemiologia , Previsões , Retinopatia Diabética/economia , Seguimentos , Saúde Global , Humanos , Prevalência , Fatores de Risco
8.
Sci Rep ; 9(1): 11751, 2019 08 13.
Artigo em Inglês | MEDLINE | ID: mdl-31409801

RESUMO

Retinal arterioles, venules and capillaries are differentially affected in diabetes, and studying vascular alterations may provide information on pathogenesis of diabetic retinopathy (DR). We conducted a cross-sectional study on 49 diabetic patients, who underwent fundus photography and optical coherence tomographic angiography (OCT-A). Fundus photographs were analysed using semi-automated software for arteriolar and venular parameters, including central retinal arteriolar equivalent (CRAE), central retinal venular equivalent (CRVE) and fractal dimension (FD). Capillary parameters were measured using OCT-A, including capillary density index (CDI) and capillary FD of superficial (SVP) and deep (DVP) vascular plexuses. Severe DR was defined as severe non-proliferative DR and proliferative DR. We found that eyes with severe DR had narrower CRAE and sparser SVP CDI than eyes without. In logistic regression analysis, capillary parameters were more associated with severe DR than arteriolar or venular parameters. However, combining arteriolar, venular and capillary parameters provided the strongest association with severe DR. In linear regression analysis, eyes with poorer visual acuity had lower CRAE and FD of arterioles, venules, and DVP capillaries. We concluded that the retinal microvasculature is globally affected in severe DR, reflecting widespread microvascular impairment in perfusion. Arteriolar, venular and capillary parameters provide complementary information in assessment of DR.


Assuntos
Angiografia/métodos , Retinopatia Diabética/diagnóstico por imagem , Fundo de Olho , Microvasos/diagnóstico por imagem , Vasos Retinianos/diagnóstico por imagem , Tomografia de Coerência Óptica/métodos , Retinopatia Diabética/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Acuidade Visual
10.
Ophthalmology ; 123(12): 2571-2580, 2016 12.
Artigo em Inglês | MEDLINE | ID: mdl-27726962

RESUMO

PURPOSE: To determine the incremental cost-effectiveness of a new telemedicine technician-based assessment relative to an existing model of family physician (FP)-based assessment of diabetic retinopathy (DR) in Singapore from the health system and societal perspectives. DESIGN: Model-based, cost-effectiveness analysis of the Singapore Integrated Diabetic Retinopathy Program (SiDRP). PARTICIPANTS: A hypothetical cohort of patients aged 55 years with type 2 diabetes previously not screened for DR. METHODS: The SiDRP is a new telemedicine-based DR screening program using trained technicians to assess retinal photographs. We compared the cost-effectiveness of SiDRP with the existing model in which FPs assess photographs. We developed a hybrid decision tree/Markov model to simulate the costs, effectiveness, and incremental cost-effectiveness ratio (ICER) of SiDRP relative to FP-based DR screening over a lifetime horizon. We estimated the costs from the health system and societal perspectives. Effectiveness was measured in terms of quality-adjusted life-years (QALYs). Result robustness was calculated using deterministic and probabilistic sensitivity analyses. MAIN OUTCOME MEASURES: The ICER. RESULTS: From the societal perspective that takes into account all costs and effects, the telemedicine-based DR screening model had significantly lower costs (total cost savings of S$173 per person) while generating similar QALYs compared with the physician-based model (i.e., 13.1 QALYs). From the health system perspective that includes only direct medical costs, the cost savings are S$144 per person. By extrapolating these data to approximately 170 000 patients with diabetes currently being screened yearly for DR in Singapore's primary care polyclinics, the present value of future cost savings associated with the telemedicine-based model is estimated to be S$29.4 million over a lifetime horizon. CONCLUSIONS: While generating similar health outcomes, the telemedicine-based DR screening using technicians in the primary care setting saves costs for Singapore compared with the FP model. Our data provide a strong economic rationale to expand the telemedicine-based DR screening program in Singapore and elsewhere.


Assuntos
Análise Custo-Benefício , Retinopatia Diabética/diagnóstico , Retinopatia Diabética/economia , Programas de Rastreamento/economia , Programas Nacionais de Saúde/economia , Telemedicina/economia , Diabetes Mellitus Tipo 2/complicações , Feminino , Custos de Cuidados de Saúde , Humanos , Masculino , Cadeias de Markov , Pessoa de Meia-Idade , Anos de Vida Ajustados por Qualidade de Vida , Singapura/epidemiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA