Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Radiat Prot Dosimetry ; 200(5): 437-447, 2024 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-38226499

RESUMO

In this study, the activity concentrations of radon (222Rn), thoron (220Rn) and thoron progeny were measured simultaneously in Djeno (Pointe-Noire, Republic of Congo) using RADUET detectors to evaluate the air quality and the radiological risks due to the inhalation of these radionuclides. Activity concentrations of radon progeny were calculated from those of radon. Indoor radon, thoron and progenies followed a lognormal distribution ranging between 20 and 40, 6 and 62, 8 and 17.6 and 0.4 and 19.6 Bq m-3 for radon, thoron, radon progeny and thoron progeny, respectively. Mean values for radon were lower than the worldwide values estimated by the United Nation Scientific Committee on the Effects of Atomic Radiation (UNSCEAR), which are 40 Bq m-3 (arithmetic mean) and 45 Bq m-3 (geometric mean). Radon concentrations in the dwellings under study were below the World Health Organization and the International Commission on Radiological Protection recommended reference levels, which are, respectively, 100 and 300 Bq m-3. The mean concentration of thoron was twice the world average value of 10 Bq m-3 estimated by UNSCEAR. Thoron progeny mean concentration was sharply greater than the typical value (0.3 Bq m-3) for indoor atmosphere provided by UNSCEAR. Annual effective dose ranges were 0.40-0.87 mSv (arithmetic mean, 0.57 ± 0.11 mSv) for radon and 0.10-4.14 mSv (arithmetic mean, 0.55 ± 0.77 mSv) for thoron. The mean value for radon was lower than the value (1.15 mSv) estimated by UNSCEAR, while the mean value for thoron was five times higher than the UNSCEAR value (0.10 mSv). The study showed that the use of the typical equilibrium factor value given by UNSCEAR to compute effective dose led to an error above 80%. Finally, the results of this study showed that the excess relative risk of radon-induced cancer was low, below 2% for the population under 55 y. The results presented in the present study prove that the population of Djeno is exposed to a relatively low potential risk of radon- and thoron-induced cancer.


Assuntos
Poluentes Radioativos do Ar , Poluição do Ar em Ambientes Fechados , Neoplasias , Monitoramento de Radiação , Radônio , Radônio/análise , Produtos de Decaimento de Radônio/análise , Poluentes Radioativos do Ar/análise , Congo , Poluição do Ar em Ambientes Fechados/análise , Monitoramento de Radiação/métodos , Habitação , Medição de Risco
2.
Environ Sci Pollut Res Int ; 30(38): 89280-89292, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37452241

RESUMO

With a history of more than 200 years of tin mining, Bangka Island has brought along a byproduct of heavy minerals containing radionuclide elements. There are some concerns about this byproduct material contributing to natural radiation in the environment. In this study, a car-borne survey was conducted to accurately assess natural background radiation in Bangka Island. Indoor and outdoor ambient dose rates in 146 houses were also measured to assess the radiation dose from external exposure received by the public. Soil samples were collected and measured using a gamma spectroscopy system to evaluate the contributions of specific radionuclides to external terrestrial exposure. From 3790 measurement points during the car-borne survey, the highest ambient dose equivalent rate was 596 nSv h-1 measured in Muntok area, with a mean value of 101 nSv h-1 and a median value of 95 nSv h-1. The ambient dose equivalent rate distribution map showed a relatively higher value in the northern coastal area of the island, where the Pemali tin deposit is located. The annual effective dose received from external radiation in the 146 houses in Bangka Island ranged from 0.44 to 1.30 mSv year-1, with a median value of 0.66 mSv year-1. The soil contained a relatively high amount of thorium (232Th), which contributed 69% to external radiation exposure in Bangka Island.


Assuntos
Exposição à Radiação , Monitoramento de Radiação , Poluentes Radioativos do Solo , Doses de Radiação , Estanho , Automóveis , Monitoramento de Radiação/métodos , Poluentes Radioativos do Solo/análise , Tório/análise , Radioisótopos , Raios gama , Radiação de Fundo , Solo/química , Radioisótopos de Potássio/análise
3.
Artigo em Inglês | MEDLINE | ID: mdl-35162781

RESUMO

222Rn and 226Ra concentrations of less than a few to several thousands of Bq L-1 have been observed in several underground bodies of water around the world. Although regulations for these concentrations in water have been implemented internationally, there are currently no regulations in place in Japan. However, concentrations that exceed these internationally recognized regulatory values have also been observed in Japan. In this study, concentrations in spring water in the northern part of Japan were measured and the effective dose from intake of the water was evaluated. 222Rn concentrations were measured using a liquid scintillation counter, and 226Ra concentrations were measured using a high purity germanium detector after chemical preparation. The measured 222Rn concentrations (=12.7 ± 6.1 Bq L-1) and 226Ra concentrations (<0.019-0.022 Bq L-1) did not exceed the reference values set by international and European/American organizations. A conservative estimate of the annual effective ingestion dose of 8 µSv for 222Rn and 226Ra obtained in this study is much smaller than the estimated overall annual effective dose of 2.2 mSv from natural radiation to the Japanese population. However, this dosage accounts for 8% of the WHO individual dosing criteria of 0.1 mSv/year for drinking water.


Assuntos
Água Potável , Monitoramento de Radiação , Radônio , Poluentes Radioativos da Água , Radiação de Fundo , Água Potável/análise , Ingestão de Alimentos , Doses de Radiação , Radônio/análise , Poluentes Radioativos da Água/análise , Abastecimento de Água
4.
ScientificWorldJournal ; 2021: 9978619, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34949965

RESUMO

The areas around Homa and Ruri hills in Homa Bay County in Kenya are associated with high background radiation levels. The activity concentration of the natural radionuclides (226Ra, 232Th, and 40K) in earthen building materials used in the areas of Homa and Ruri hills has been measured using a NaI (Tl) detector in this work. The measured values of radioactivity concentrations are used to estimate the associated radiological risk. The earthen building material samples from Ruri registered relatively high 232Th concentration values averaging 1094 ± 55 Bq/kg, nearly three times those of the samples from Homa. 226Ra level was not significantly different in both regions with Homa reporting 129 ± 10 Bq/kg and Ruri 111 ± 6 Bq/kg. 40K was however higher in the samples from Homa by an approximate factor of 2 relative to those from Ruri where the activity concentration was 489 ± 24 Bq/kg. The radium equivalents for 226Ra, 232Th, and 40K in the samples from Ruri were 111 ± 9, 1564 ± 125, and 38 ± 3 Bq/kg, while in Homa, the values were 129 ± 10, 570 ± 46, and 69 ± 5 Bq/kg, respectively. The calculated value of total radium equivalent in Ruri was 1713 ± 137 Bq/kg which was two times higher than that of Homa. 232Th contributed about 74% and 91% to the total radium equivalent in Homa and Ruri, respectively; thus, it was the one with the largest contribution to radiation exposure in both regions. The average indoor annual effective dose rates were 1.74 ± 0.14 and 3.78 ± 0.30 mSv/y in Homa and Ruri, respectively, both of which were above the recommended safety limit of 1 mSv/y.


Assuntos
Radiação de Fundo , Materiais de Construção , Poluentes Radioativos/análise , Humanos , Quênia , Poluentes Radioativos/toxicidade , Poluentes Radioativos do Solo/análise , Poluentes Radioativos do Solo/toxicidade , Espectrometria gama
5.
Sci Rep ; 11(1): 6162, 2021 03 17.
Artigo em Inglês | MEDLINE | ID: mdl-33731779

RESUMO

Emergency medical responders (EMRs) who treat victims during a radiation emergency are at risk of radiation exposure. In this study, the exposure dose to EMRs treating hypothetically contaminated patients was estimated using a Monte Carlo simulation, and the findings may be useful for educating EMRs and reducing their anxiety. The Monte Carlo simulation estimated radiation doses for adult computational phantoms based on radioactive contamination conditions and radiation dosages from previous studies. At contamination conditions below the typical upper limit of general Geiger-Müller survey meters, the radiation doses to EMRs were estimated to be less than 1 µSv per hour. In cases with greater contamination due to mishandling of an intense radioactive source (hundreds of GBq), the radiation doses to EMRs could reach approximately 100 mSv per hour. These results imply that a radiological accident with a highly radioactive source could expose EMR to significant radiation that exceeds their dose limit. Thus, authorities and other parties should ensure that EMRs receive appropriate education and training regarding measures that can be taken to protect themselves from the possibility of excessive radiation exposure. The results of this study may provide EMRs with information to take appropriate protective measures, although it is also important that they not hesitate to perform lifesaving measures because of concerns regarding radiation.


Assuntos
Socorristas , Doses de Radiação , Exposição à Radiação/análise , Monitoramento de Radiação , Proteção Radiológica , Humanos , Método de Monte Carlo , Imagens de Fantasmas , Monitoramento de Radiação/instrumentação , Monitoramento de Radiação/métodos , Liberação Nociva de Radioativos
6.
Artigo em Inglês | MEDLINE | ID: mdl-33494398

RESUMO

The world community has long used natural hot springs for tourist and medicinal purposes. In Indonesia, the province of West Java, which is naturally surrounded by volcanoes, is the main destination for hot spring tourism. This paper is the first report on radon measurements in tourism natural hot spring water in Indonesia as part of radiation protection for public health. The purpose of this paper is to study the contribution of radon doses from natural hot spring water and thereby facilitate radiation protection for public health. A total of 18 water samples were measured with an electrostatic collection type radon monitor (RAD7, Durridge Co., USA). The concentration of radon in natural hot spring water samples in the West Java region, Indonesia ranges from 0.26 to 31 Bq L-1. An estimate of the annual effective dose in the natural hot spring water area ranges from 0.51 to 0.71 mSv with a mean of 0.60 mSv for workers. Meanwhile, the annual effective dose for the public ranges from 0.10 to 0.14 mSv with an average of 0.12 mSv. This value is within the range of the average committed effective dose from inhalation and terrestrial radiation for the general public, 1.7 mSv annually.


Assuntos
Fontes Termais , Monitoramento de Radiação , Radônio , Poluentes Radioativos da Água , Humanos , Indonésia , Doses de Radiação , Radônio/análise , Água , Poluentes Radioativos da Água/análise
7.
Sci Total Environ ; 750: 142346, 2021 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-33182182

RESUMO

The biological effects of low dose-rate radiation exposures on humans remains unknown. In fact, the Japanese nation still struggles with this issue after the Fukushima Dai-ichi Nuclear Power Plant accident. Recently, we have found a unique area in Indonesia where naturally high radiation levels are present, resulting in chronic low dose-rate radiation exposures. We aimed to estimate the comprehensive dose due to internal and external exposures at the particularly high natural radiation area, and to discuss the enhancement mechanism of radon. A car-borne survey was conducted to estimate the external doses from terrestrial radiation. Indoor radon measurements were made in 47 dwellings over three to five months, covering the two typical seasons, to estimate the internal doses. Atmospheric radon gases were simultaneously collected at several heights to evaluate the vertical distribution. The absorbed dose rates in air in the study area vary widely between 50 nGy h-1 and 1109 nGy h-1. Indoor radon concentrations ranged from 124 Bq m-3 to 1015 Bq m-3. That is, the indoor radon concentrations measured exceed the reference levels of 100 Bq m-3 recommended by the World Health Organization. Furthermore, the outdoor radon concentrations measured were comparable to the high indoor radon concentrations. The annual effective dose due to external and internal exposures in the study area was estimated to be 27 mSv using the median values. It was found that many residents are receiving radiation exposure from natural radionuclides over the dose limit for occupational exposure to radiation workers. This enhanced outdoor radon concentration might be as a result of the stable atmospheric conditions generated at an exceptionally low altitude. Our findings suggest that this area provides a unique opportunity to conduct an epidemiological study related to health effects due to chronic low dose-rate radiation exposure.


Assuntos
Poluentes Radioativos do Ar , Poluição do Ar em Ambientes Fechados , Monitoramento de Radiação , Radônio , Poluentes Radioativos do Ar/análise , Poluição do Ar em Ambientes Fechados/análise , Radiação de Fundo , Humanos , Indonésia , Doses de Radiação , Radônio/análise
8.
Artigo em Inglês | MEDLINE | ID: mdl-32664497

RESUMO

Activity concentrations of 234U, 235U, 238U, 226Ra, 228Ra, 222Rn, 210Po, 210Pb, 40K, 3H, 14C, 134Cs and 137Cs were determined in 20 different Japanese bottled drinking water commercially available in Japan. The origins of the mineral water samples were geographically distributed across different regions of Japan. Activity concentrations above detection limits were measured for the radionuclides 234U, 235U, 238U, 226Ra, 228Ra and 210Po. An average total annual effective dose due to ingestion was estimated for adults, based on the average annual volume of bottled water consumed in Japan in 2019, reported to be 31.7 L/y per capita. The estimated dose was found to be below the recommended World Health Organisation (WHO) guidance level of 0.1 mSv/y for drinking water quality. The most significant contributor to the estimated dose was 228Ra.


Assuntos
Água Potável/análise , Doses de Radiação , Monitoramento de Radiação , Poluentes Radioativos da Água/análise , Humanos , Japão
9.
Isotopes Environ Health Stud ; 55(5): 499-510, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31394926

RESUMO

Radon, thoron and associated progeny measurements have been carried out in 71 dwellings of Douala city, Cameroon. The radon-thoron discriminative detectors (RADUET) were used to estimate the radon and thoron concentration, while thoron progeny monitors measured equilibrium equivalent thoron concentration (EETC). Radon, thoron and thoron progeny concentrations vary from 31 ± 1 to 436 ± 12 Bq m-3, 4 ± 7 to 246 ± 5 Bq m-3, and 1.5 ± 0.9 to 13.1 ± 9.4 Bq m-3. The mean value of the equilibrium factor for thoron is estimated at 0.11 ± 0.16. The annual effective dose due to exposure to indoor radon and progeny ranges from 0.6 to 9 mSv a-1 with an average value of 2.6 ± 0.1 mSv a-1. The effective dose due to the exposure to thoron and progeny vary from 0.3 to 2.9 mSv a-1 with an average value of 1.0 ± 0.4 mSv a-1. The contribution of thoron and its progeny to the total inhalation dose ranges from 7 to 60 % with an average value of 26 %; thus their contributions should not be neglected in the inhalation dose assessment.


Assuntos
Poluentes Radioativos do Ar/análise , Poluição do Ar em Ambientes Fechados/análise , Exposição por Inalação/análise , Produtos de Decaimento de Radônio/análise , Radônio/análise , Camarões , Habitação , Humanos , Monitoramento de Radiação/instrumentação , Monitoramento de Radiação/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA