Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
J Funct Biomater ; 14(3)2023 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-36976092

RESUMO

Tissue adhesives constitute a great possibility to improve conventional wound closure. In contrast to sutures, they enable nearly immediate hemostasis and can prevent fluid or air leaks. In the present study, a poly(ester)urethane-based adhesive was investigated which already proved to be suitable for different indications, such as reinforcing vascular anastomosis and sealing liver tissue. Using in vitro and in vivo setups, the degradation of the adhesives was monitored over a period of up to 2 years, to evaluate long-term biocompatibility and determine degradation kinetics. For the first time, the complete degradation of the adhesive was documented. In subcutaneous locations, tissue residues were found after 12 months and in intramuscular locations, tissue degradation was complete after about 6 months. A detailed histological evaluation of the local tissue reaction revealed good biocompatibility throughout the different degradation stages. After full degradation, complete remodeling to physiological tissue was observed at the implant locations. In addition, this study critically discusses common issues related to the assessment of biomaterial degradation kinetics in the context of medical device certification. This work highlighted the importance and encouraged the implementation of biologically relevant in vitro degradation models to replace animal studies or at least reduce the number of animals in preclinical testing prior to clinical studies. Moreover, the suitability of frequently used implantation studies based on ISO 10993-6 at standard locations was critically discussed, especially in light of the associated lack of reliable predictions for degradation kinetics at the clinically relevant site of implantation.

3.
Anim Welf ; 32: e29, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38487427

RESUMO

Severity assessment in animals is an ongoing field of research. In particular, the question of objectifiable and meaningful parameters of score-sheets, as well as their best combination, arise. This retrospective analysis investigates the suitability of a score-sheet for assessing severity and seeks to optimise it for predicting survival in 89 male Sprague Dawley rats (Rattus norvegicus), during an experiment evaluating the influence of liver cirrhosis by bile duct ligation (BDL) on vascular healing. The following five parameters were compared for their predictive power: (i) overall score; (ii) relative weight loss; (iii) general condition score; (iv) spontaneous behaviour score; and (v) the observer's assessment whether pain might be present. Suitable cut-off values of these individual parameters and the combination of multiple parameters were investigated. A total of ten rats (11.2%; 10/89) died or had to be sacrificed at an early stage due to pre-defined humane endpoints. Neither the overall score nor any individual parameter yielded satisfactory results for predicting survival. Using retrospectively calculated cut-off values and combining the overall score with the observer's assessment of whether the animal required analgesia (dipyrone) for pain relief resulted in an improved prediction of survival on the second post-operative day. This study demonstrates that combining score parameters was more suitable than using single ones and that experienced human judgement of animals can be useful in addition to objective parameters in the assessment of severity. By optimising the score-sheet and better understanding the burden of the model on rats, this study contributes to animal welfare.

4.
Sci Rep ; 10(1): 15790, 2020 09 25.
Artigo em Inglês | MEDLINE | ID: mdl-32978437

RESUMO

The Directive 2010/63 EU requires classifying burden and severity in all procedures using laboratory animals. This study evaluated the severity of liver fibrosis induction by intraperitoneal carbon tetrachloride (CCl4) injections in mice. 29 male C57BL/6N mice were treated three times per week for 4 weeks with an intraperitoneal injection (50 µl) of either 0.6 ml/kg body weight CCl4-vehicle solution, germ oil (vehicle-control) or handling only. Severity assessment was performed using serum analysis, behavioral tests (open field test, rotarod, burrowing and nesting behavior), fecal corticosterone metabolite (FCM) measurement, and survival. The most significant group differences were noticed in the second week of treatment when the highest AST (1463 ± 1404 vs. 123.8 ± 93 U/L, p < 0.0001) and nesting values were measured. In addition, respective animals showed lower moving distances (4622 ± 1577 vs. 6157 ± 2060 cm, p < 0.01) and velocity in the Open field, identified as main factors in principal component analysis (PCA). Overall, a 50% survival rate was observed within the treatment group, in which the open field performance was a good tracer parameter for survival. In summary, this study demonstrates the feasibility of assessing severity in mice using behavioral tests and highlight the open field test as a possible threshold parameter for risk assessment of mortality.


Assuntos
Comportamento Animal/efeitos dos fármacos , Tetracloreto de Carbono/toxicidade , Modelos Animais de Doenças , Cirrose Hepática/patologia , Índice de Gravidade de Doença , Animais , Tetracloreto de Carbono/administração & dosagem , Injeções Intraperitoneais , Cirrose Hepática/induzido quimicamente , Masculino , Camundongos , Camundongos Endogâmicos C57BL
5.
Lab Anim ; 54(6): 525-535, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32228147

RESUMO

The aim of this pilot study was to evaluate whether behavioral or locomotor tests (Open Field (OF), rotarod (RR), and CatWalk (CW)) can help assess the severity of laparotomy in rats.The new EU Directive (2010/63/EU) mandates severity assessment in experiments involving animals. However, validated and objective methods are needed to relate trial-specific monitoring results to the degree of distress caused to individual animals. Therefore, we focused on non-invasive or minimally invasive, simple, and convenient severity assessment methods in a surgical model.To evaluate surgical severity in this model, we compared moving velocity among three commonly used behavioral test methods (OF, RR, and CW) after midline laparotomy within postoperative 7 days.In this study, 30 adult male Wistar Han rats (n = 10 per test) were trained in their assigned test method and subsequently subjected to surgery. Severity scoring was performed daily using a modified score sheet developed previously. In addition, blood and fecal samples were collected to analyze surgical and postoperative corticosterone metabolite levels. We found significant differences among the experimental groups in terms of the analyzed parameters. In this context, the OF test was found to be the most suitable method for severity assessment after laparotomy in rats.


Assuntos
Escala de Avaliação Comportamental , Laparotomia/efeitos adversos , Locomoção , Animais , Masculino , Projetos Piloto , Ratos , Ratos Wistar
7.
Lab Anim ; 54(1): 33-39, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31488040

RESUMO

Severity assessment in animal models is a data-driven process. We therefore present a use case for building a repository for interlaboratory collaboration with the potential of uploading specific content, making group announcements and internal prepublication discussions. We clearly show that it is possible to offer such a structure with minimal effort and a basic understanding of web-based services, also taking into account the human factor in individual data collection. The FOR2591 Online Repository serves as a blueprint for other groups, so that one day not only will data sharing among consortium members be improved but the transition from the private to the persistent domain will also be easier.


Assuntos
Criação de Animais Domésticos/métodos , Bem-Estar do Animal , Animais de Laboratório , Disseminação de Informação/métodos , Armazenamento e Recuperação da Informação/métodos , Criação de Animais Domésticos/instrumentação , Animais
9.
J Vis Exp ; (138)2018 08 04.
Artigo em Inglês | MEDLINE | ID: mdl-30124636

RESUMO

Plasma coagulation as a form of electrocautery is used in liver surgery for decades to seal the large liver cut surface after major hepatectomy to prevent hemorrhages at a later stage. The exact effects of plasma coagulation on liver tissue are only poorly examined. In our porcine model, the coagulation effects can be examined close to the clinical application. A combined laser Doppler flowmeter and spectrophotometer documents microcirculation changes during coagulation at 8 mm tissue depth noninvasively, providing quantifiable information about hemostasis beyond the subjective clinical impression. The temperature at coagulation site is assessed with an infrared thermometer prior and post coagulation and with a thermographic camera during coagulation, a measurement of the gas beam temperature is not possible due to the upper threshold of the devices. The depth of coagulation is measured microscopically on hematoxylin/eosin stained sections after calibration with an object micrometer and gives an exact information about the power setting-coagulation depth-relation. The sealing effect is examined on the bile ducts as it is not possible for a plasma coagulator to seal larger blood vessels. Burst pressure experiments are carried out on explanted organs to rule out blood pressure related effects.


Assuntos
Coagulação Sanguínea/fisiologia , Fígado/metabolismo , Animais , Modelos Animais de Doenças , Fígado/citologia , Suínos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA