J Chromatogr A ; 919(1): 87-93, 2001 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-11459315

RESUMO

A liquid chromatographic method for determination of the residues of ranitidine hydrochloride on various surfaces employed in drug manufacture is described. Cotton swabs, moistened with a methanol-water (1:1, v/v) mixture were used to remove any residues of drugs from glass, vinyl, and stainless steel surfaces, and gave recoveries of 85%, 78% and 90%, respectively. Residues were determined by high-performance liquid chromatography on a C18 column at 25 degrees C with methanol-ammonium acetate (40:60 v/v) pH 6.7 as the mobile phase and detection at 320 nm. The method was validated over a concentration range of 20-10 000 ng/ml and had a detection limit of 2 ng/ml.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Antagonistas dos Receptores H2 da Histamina/análise , Ranitidina/análise , Indústria Farmacêutica