Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Am Med Inform Assoc ; 27(5): 808-817, 2020 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-32181812

RESUMO

OBJECTIVE: Use of medical scribes reduces clinician burnout by sharing the burden of clinical documentation. However, medical scribes are cost-prohibitive for most settings, prompting a growing interest in developing ambient, speech-based technologies capable of automatically generating clinical documentation based on patient-provider conversation. Through a systematic review, we aimed to develop a thorough understanding of the work performed by medical scribes in order to inform the design of such technologies. MATERIALS AND METHODS: Relevant articles retrieved by searching in multiple literature databases. We conducted the screening process following the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) in guidelines, and then analyzed the data using qualitative methods to identify recurring themes. RESULTS: The literature search returned 854 results, 65 of which met the inclusion criteria. We found that there is significant variation in scribe expectations and responsibilities across healthcare organizations; scribes also frequently adapt their work based on the provider's style and preferences. Further, scribes' job extends far beyond capturing conversation in the exam room; they also actively interact with patients and the care team and integrate data from other sources such as prior charts and lab test results. DISCUSSION: The results of this study provide several implications for designing technologies that can generate clinical documentation based on naturalistic conversations taking place in the exam room. First, a one-size-fits-all solution will be unlikely to work because of the significant variation in scribe work. Second, technology designers need to be aware of the limited role that their solution can fulfill. Third, to produce comprehensive clinical documentation, such technologies will likely have to incorporate information beyond the exam room conversation. Finally, issues of patient consent and privacy have yet to be adequately addressed, which could become paramount barriers to implementing such technologies in realistic clinical settings. CONCLUSIONS: Medical scribes perform complex and delicate work. Further research is needed to better understand their roles in a clinical setting in order to inform the development of speech-based clinical documentation technologies.


Assuntos
Pessoal Técnico de Saúde , Documentação/métodos , Registros Eletrônicos de Saúde , Reconhecimento de Voz , Pessoal Técnico de Saúde/economia , Pessoal Técnico de Saúde/educação , Humanos , Interface para o Reconhecimento da Fala
2.
Microcirculation ; 23(4): 293-300, 2016 05.
Artigo em Inglês | MEDLINE | ID: mdl-26998587

RESUMO

OBJECTIVES: To determine whether stability/accuracy of post-occlusive LDF following shortened, one-minute blood flow occlusion, increases in the post-exercise state or by averaging multiple measurements. METHODS: Six healthy adults (3F) underwent LDF eight times at rest and following exercise, assessing post-occlusive (one-minute occlusion) reactive hyperemia in the cutaneous microcirculation of the forefinger. Measured variables included: pre- and post-occlusion steady-state perfusion (Plat1, Plat2), maximum post-occlusive perfusion (Max), PkT, and the ratio Max/Plat1. RESULTS: Stability/accuracy of all variables improved performing measurements after exercise (p < 0.05 Plat 1, Plat 2, Max and Max/Plat1). PkT and Max/Plat 1 displayed the greatest accuracy at rest (26.6 ± 5.1% and 26.6 ± 4.4% average difference, %Diff, of single measurements from individual "true" means, respectively); for these variables, %Diff improved to 19.5 ± 5.3 and 17.6 ± 2.1, respectively, following exercise. Overall, averaging multiple measurements performed at rest also improved stability/accuracy in all variables. This improvement was comparable to that obtained with a single measurement following exercise. CONCLUSIONS: A standardized exercise stimulus prior to testing significantly improves stability/accuracy of LDF following shortened, one-minute blood flow occlusion. Our results suggest the possibilities of broader applications of exercise to optimize measurements from a variety of skin perfusion methodologies.


Assuntos
Exercício Físico/fisiologia , Fluxometria por Laser-Doppler/normas , Microcirculação/fisiologia , Adulto , Feminino , Dedos/irrigação sanguínea , Humanos , Hiperemia/fisiopatologia , Fluxometria por Laser-Doppler/métodos , Masculino , Fluxo Sanguíneo Regional , Reprodutibilidade dos Testes , Pele/irrigação sanguínea , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA