Circ Arrhythm Electrophysiol ; 12(2): e006878, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30707036

RESUMO

BACKGROUND: The 12-lead ECG is considered the gold standard to differentiate between selective (S), nonselective (NS) His bundle pacing (HBP), and right ventricular septal capture in routine clinical practice. We sought to assess the utility of device EGM recordings as a tool to identify the type of HBP morphology. METHODS: One hundred forty-eight consecutive patients underwent HBP with a 3830 Select Secure lead (Medtronic, Inc) at 3 centers between October 2016 and October 2017. The near field V-EGM morphology (NF EGM), near field V-EGM time to peak (NFTime to peak), and far-field EGM QRS duration (QRSd) were recorded while pacing the His lead with simultaneous 12-lead ECG rhythm strips. RESULTS: Indications for HBP were sinus node dysfunction, atrioventricular conduction disease, and cardiac resynchronization therapy in 68 (46%), 56 (38%), and 24 (16%) patients, respectively. Baseline QRSd was 108±38 ms with QRSd >120 ms in 57 (39%) patients (27 right bundle branch block, 18 left bundle branch block, and 12 intraventricular conduction delay). S-HBP was noted in 54 (36%) patients. A positive NFEGM and NFTime to peak >40 ms were highly sensitive (94% and 93%, respectively) and specific (90% and 94%) for S-HBP irrespective of baseline QRSd. All 3 parameters (+NFEGM, NFTime to peak >40 ms, and far-field EGM QRSd <120 ms) had high negative predictive value (97%, 95%, and 92%). A novel device-based algorithm for S-HBP was proposed. EGM transitions correlated with ECG transitions during threshold testing and can help accurately differentiate between S-HBP, NS-HBP, and right ventricular septal pacing with a cumulative positive predictive value of 91% (positive predictive value =100% in patients with baseline QRSd <120 ms). CONCLUSIONS: We propose a novel and simple criteria for accurate differentiation between S-HBP, NS-HBP, and right ventricular septal capture morphologies by careful analysis of device EGMs alone. This study paves the way for future studies to assess autocapture algorithms for devices with HBP.


Assuntos
Potenciais de Ação , Arritmias Cardíacas/terapia , Fascículo Atrioventricular/fisiopatologia , Estimulação Cardíaca Artificial/métodos , Técnicas Eletrofisiológicas Cardíacas , Insuficiência Cardíaca/terapia , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatologia , Eletrocardiografia , Feminino , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Processamento de Sinais Assistido por Computador , Fatores de Tempo , Resultado do Tratamento , Estados Unidos , Função Ventricular Direita
3.
J Nucl Cardiol ; 20(4): 519-28, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23475438

RESUMO

BACKGROUND: The prognostic value of single-photon emission computed-tomography (SPECT)-myocardial perfusion imaging (MPI) is well documented. However, the utility of SPECT-MPI when performed at a low-volume primary care physician's (PCP's) office is unknown. METHODS: We conducted a prospective cohort study of consecutive patients referred by their PCP to undergo a stress-MPI at the PCP's office using a mobile laboratory. Major adverse cardiovascular events (MACE) of death, myocardial infarction (MI), and coronary revascularization were prospectively tabulated using mail and telephone interviews, chart review, and social security death index. RESULTS: One thousand three hundred ninety subjects [mean age 58 ± 13 years; 44% women] were followed for 27 ± 9 months, with a 99% complete follow-up rate. Subjects with abnormal MPI [174 (12.5%)] had significantly higher rates of all-cause mortality [5.2% vs 1.0%, P < .001], death, or MI [5.7% vs 1.5%, P = .001], and the composite of death, MI, or late revascularization (>60 days post-MPI) [12.6 vs 2.7%, P < .001]. Overall MACE risk was associated with the total perfusion abnormality burden, while the revascularization rate was related to the reversible perfusion abnormality burden. CONCLUSION: Contemporary SPECT-MPI performed in the setting of a PCP's office carries a robust prognostic value, similar to that reported in tertiary or large-volume practice settings.


Assuntos
Coração/diagnóstico por imagem , Imagem de Perfusão do Miocárdio/métodos , Atenção Primária à Saúde/métodos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Idoso , Causas de Morte , Feminino , Seguimentos , Fidelidade a Diretrizes , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/diagnóstico por imagem , Perfusão , Prognóstico , Estudos Prospectivos