Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
2.
Heart Lung Circ ; 24(10): 1011-9, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25991392

RESUMO

BACKGROUND: Repeat cardiac surgeries are well known to have higher rates of complications, one of the important reasons being injuries associated with re-do sternotomy. Routine imaging with CT can help to minimise this risk by pre-operatively assessing the anatomical relation between the sternum and the underlying cardiovascular structures, but is limited by its inability to determine the presence and severity of functional tethering and adhesions between these structures. However, with the evolution of wide area detector MD CT scanners, it is possible to assess the presence of tethering using the dynamic four-dimensional CT (4D CT) imaging technique. METHODS: Nineteen patients undergoing re-do cardiac surgery were pre-operatively imaged using dynamic 4D CT during regulated respiration. The datasets were assessed in cine mode for presence of differential motion between sternum and underlying cardiovascular structures which indicates lack of significant tethering. RESULTS: Overall, there was excellent correlation between preoperative imaging and intraoperative findings. The technique enabled our surgeons to meticulously plan the procedures and to avoid re-entry related injuries. CONCLUSIONS: Our initial experience shows that dynamic 4D CT is useful in risk stratification prior to re-do sternotomy by determining the presence or absence of tethering between sternum and underlying structures based on assessment of differential motion. Furthermore we determined the technique to be superior to non-dynamic assessment of retrocardiac tethering.


Assuntos
Tomografia Computadorizada Quadridimensional , Esternotomia/efeitos adversos , Aderências Teciduais/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Cuidados Pré-Operatórios , Reoperação , Medição de Risco/métodos , Esterno , Aderências Teciduais/etiologia
3.
Eur J Cardiothorac Surg ; 47(2): 239-43; discussion 243, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25082145

RESUMO

OBJECTIVES: The 320-slice computed tomography (CT) provides three-dimensional and dynamic imaging resulting in the ability to assess motion analysis between two adjacent structures (the fourth dimension). Differential movements between two adjacent structures would indicate that there is no fixation between the two structures. METHODS: Eight patients with non-small-cell lung cancers located adjacent to vital structures (e.g. the great vessels) (n = 4), mediastinum (n = 1) or chest wall (n = 3) where conventional CT was unable to exclude local invasion underwent dynamic four-dimensional (4D) CT assessment. In 3 patients, the lung tumour was abutting the chest wall and 1 patient had tumour abutting the mediastinum. The remaining patients included a patient with a large 14-cm left lower lobe cancer abutting the descending thoracic aorta who had previous pleurodesis; a patient with an apical right upper lobe 6-cm cancer with static imaging appearances suggestive of tumour invasion into the apex, the mediastinal surface and superior vena cava (SVC); a patient with a 3.5-cm cancer which had a broad 2.5-cm base abutting the distal aortic arch and a patient with a 14-cm left upper lobe cancer abutting the aortic arch, descending thoracic aorta and chest wall. Differential movements between the tumour and adjacent structure on 4D CT were considered indicative of the absence of frank invasion. RESULTS: Dynamic 4D imaging revealed differential movements between the tumour and the adjacent structures in 7 cases, suggesting the absence of overt malignant invasion. Intraoperative assessments confirmed the findings. In 1 case, a small area of fixation seen on dynamic CT corresponded intraoperatively to superficial invasion of the adventitia of the SVC. CONCLUSIONS: Dynamic 4D 320-slice CT is useful in the preoperative assessment of the direct invasion of lung cancer into adjacent structures and hence its resectability.


Assuntos
Carcinoma Pulmonar de Células não Pequenas/diagnóstico por imagem , Tomografia Computadorizada Quadridimensional/métodos , Neoplasias Pulmonares/diagnóstico por imagem , Invasividade Neoplásica/diagnóstico por imagem , Idoso , Carcinoma Pulmonar de Células não Pequenas/patologia , Feminino , Humanos , Neoplasias Pulmonares/patologia , Masculino , Pessoa de Meia-Idade , Invasividade Neoplásica/patologia , Cuidados Pré-Operatórios
4.
J Am Coll Cardiol ; 63(18): 1904-12, 2014 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-24657696

RESUMO

OBJECTIVES: The goal of this study was to compare the diagnostic accuracy of combined computed tomography perfusion (CTP) + computed tomography angiography (CTA), transluminal attenuation gradient by 320-detector row computed tomography (TAG320) + CTA, and CTP + TAG320 + CTA (multidetector computed tomography-integrated protocol [MDCT-IP]) assessment in predicting significant fractional flow reserve (FFR). BACKGROUND: CTA has limited specificity for predicting functionally significant stenoses. Novel CT techniques, including adenosine stress CTP and TAG320, may improve the diagnostic accuracy of CTA. METHODS: CTA, CTP, and TAG320 were assessed using 320-detector row MDCT. Patients who underwent CTA, CTP, and FFR assessment on invasive coronary angiography were included. CTP was assessed using the visual perfusion assessment. TAG320 was defined as the linear regression coefficient between luminal attenuation and axial distance. A TAG320 cutoff value of -15.1 HU/10 mm as previously described was defined as significant. Functionally significant coronary stenosis was defined as FFR ≤0.8. RESULTS: The cohort included 75 patients (age 64.1 ± 10.8 years, 52 men) and 44 (35%) FFR-significant vessels. In 127 vessels, CTA predicted FFR-significant stenosis with 89% sensitivity and 65% specificity compared with MDCT-IP, which showed 88% sensitivity and 83% specificity. In 97 vessels in which the results of all techniques were available, TAG320 + CTA (area under the curve [AUC] = 0.844) and CTP + CTA (AUC = 0.845) had comparable per-vessel diagnostic accuracy (p = 0.98). The diagnostic accuracy of MDCT-IP (AUC = 0.91) was superior to TAG320 + CTA or CTP + CTA (p = 0.01). CONCLUSIONS: In vessels without significant calcification or artefact, TAG320 + CTA and CTP + CTA provide comparable diagnostic accuracy for functional assessment of coronary artery stenosis. MDCT-IP may provide the best diagnostic accuracy for functional assessment of coronary artery stenosis.


Assuntos
Adenosina , Angiografia Coronária/normas , Estenose Coronária/diagnóstico por imagem , Teste de Esforço/normas , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Tomografia Computadorizada Multidetectores/normas , Idoso , Estudos de Coortes , Estenose Coronária/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Imagem de Perfusão , Estudos Retrospectivos
5.
J Med Imaging Radiat Oncol ; 57(4): 444-7, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23870340

RESUMO

After the advent of ECG gated cardiac CT angiography (CCTA) there has been significant improvement in image quality of the ascending aorta. As a result the sinuses of valsalva are readily assessable. Sinuses of valsalva aneurysm can cause significant dysfunction of the aortic root and annulus and can be congenital or acquired. The aneurysm most commonly originates from the right coronary sinus. Complications related to sinuses of valsalva aneurysm can cause chest pain and can be life threatening. The cardiac imager should actively assess the sinuses of valsalva in every CCTA study.


Assuntos
Aneurisma Aórtico/diagnóstico por imagem , Aortografia/métodos , Técnicas de Imagem de Sincronização Cardíaca/métodos , Angiografia Coronária/métodos , Intensificação de Imagem Radiográfica/métodos , Seio Aórtico/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA