Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
World J Urol ; 41(5): 1309-1315, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36930254

RESUMO

PURPOSE: To describe the national-level patterns of care for local ablative therapy among men with PCa and identify patient- and hospital-level factors associated with the receipt of these techniques. METHODS: We retrospectively interrogated the National Cancer Database (NCDB) for men with clinically localized PCa between 2010 and 2017. The main outcome was receipt of local tumor ablation with either cryo- or laser-ablation, and "other method of local tumor destruction including high-intensity focused ultrasound (HIFU)". Patient level, hospital level, and demographic variables were collected. Mixed effect logistic regression models were fitted to identify separately patient- and hospital-level predictors of receipt of local ablative therapy. RESULTS: Overall, 11,278 patients received ablative therapy, of whom 78.8% had cryotherapy, 15.6% had laser, and 5.7% had another method including HIFU. At the patient level, men with intermediate-risk PCa were more likely to be treated with local ablative therapy (OR 1.05; 95% CI 1.00-1.11; p = 0.05), as were men with Charlson Comorbidity Index > 1 (OR 1.36; 95% CI 1.29-1.43; p < 0.01), men between 71 and 80 years (OR 3.70; 95% CI 3.43-3.99; p < 0.01), men with Medicare insurance (OR 1.38; 95% 1.31-1.46; p < 0.01), and an income < $47,999 (OR 1.16; 95% CI 1.06-1.21; p < 0.01). At the hospital-level, local ablative therapy was less likely to be performed in academic/research facilities (OR 0.45; 95% CI 0.32-0.64; p < 0.01). CONCLUSIONS: Local ablative therapy for PCa treatment is more commonly offered among older and comorbid patients. Future studies should investigate the uptake of these technologies in non-hospital-based settings and in light of recent changes in insurance coverage.


Assuntos
Terapia a Laser , Neoplasias da Próstata , Masculino , Humanos , Idoso , Estados Unidos , Estudos Retrospectivos , Medicare , Neoplasias da Próstata/cirurgia , Neoplasias da Próstata/patologia , Sistema de Registros
2.
Abdom Radiol (NY) ; 46(7): 3437-3447, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33606061

RESUMO

PURPOSE: To evaluate 18F-fluorodeoxyglucose (FDG) perfusion PET during FDG PET/CT-guided liver tumor microwave ablation procedures for assessing the ablation margin and correlating minimum margin measurements with local progression. METHODS: This IRB-approved, HIPAA-compliant study included 20 adult patients (11 M, 9 F; mean age 65) undergoing FDG PET/CT-guided liver microwave ablation to treat 31 FDG-avid tumors. Intraprocedural FDG perfusion PET was performed to assess the ablation margin. Intraprocedural decisions regarding overlapping ablations were recorded. Two readers retrospectively interpreted intraprocedural perfusion PET and postprocedural contrast-enhanced MRI. Assessability of the ablation margin and minimum margin measurements were recorded. Imaging follow-up for local progression ranged from 30 to 574 days (mean 310). Regression modeling of minimum margin measurements was performed. Hazard ratios were calculated to correlate an ablation margin threshold of 5 mm with outcomes. RESULTS: Intraprocedural perfusion PET prompted additional overlapping ablations of two tumors, neither of which progressed. Incomplete ablation or local progression occurred in 8/31 (26%) tumors. With repeat ablation, secondary efficacy was 26 (84%) of 31. Both study readers deemed ablation margins fully assessable more often using perfusion PET than MRI (OR 69.7; CI 6.0, 806.6; p = 0.001). Minimum ablation margins ≥ 5 mm on perfusion PET correlated with a low risk of incomplete ablation/local progression by both study readers (HR 0.08 and 0.02, p < 0.001). CONCLUSION: Intraprocedural FDG perfusion PET consistently enabled complete liver tumor microwave ablation margin assessments, and the perfusion PET minimum ablation margin measurements correlated well with local outcomes. Clinical trial registration clinicaltrials.gov (NCT02018107).


Assuntos
Fluordesoxiglucose F18 , Neoplasias Hepáticas , Adulto , Idoso , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/cirurgia , Perfusão , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Tomografia por Emissão de Pósitrons , Estudos Retrospectivos
3.
Med Phys ; 47(6): 2337-2349, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32141080

RESUMO

PURPOSE: Magnetic resonance imaging (MRI)-guided percutaneous cryotherapy of abdominal lesions, an established procedure, uses MRI to guide and monitor the cryoablation of lesions. Methods to precisely guide cryotherapy probes with a minimum amount of trial-and-error are yet to be established. To aid physicians in attaining precise probe alignment without trial-and-error, a body-mounted motorized cryotherapy-probe alignment device (BMCPAD) with motion compensation was clinically tested in this study. The study also compared the contribution of body motion and organ motion compensation to the guidance accuracy of a body-mounted probe alignment device. METHODS: The accuracy of guidance using the BMCPAD was prospectively measured during MRI-guided percutaneous cryotherapies before insertion of the probes. Clinical parameters including patient age, types of anesthesia, depths of the target, and organ sites of target were collected. By using MR images of the target organs and fiducial markers embedded in the BMCPAD, we retrospectively simulated the guidance accuracy with body motion compensation, organ motion compensation, and no compensation. The collected data were analyzed to test the impact of motion compensation on the guidance accuracy. RESULTS: Thirty-seven physical guidance of probes were prospectively recorded for sixteen completed cases. The accuracy of physical guidance using the BMCPAD was 13.4 ± 11.1 mm. The simulated accuracy of guidance with body motion compensation, organ motion compensation, and no compensation was 2.4 ± 2.9 mm, 2.2 ± 1.6 mm, and 3.5 ± 2.9 mm, respectively. Data analysis revealed that the body motion compensation and organ motion compensation individually impacted the improvement in the accuracy of simulated guidance. Moreover, the difference in the accuracy of guidance either by body motion compensation or organ motion compensation was not statistically significant. The major clinical parameters impacting the accuracy of guidance were the body and organ motions. Patient age, types of anesthesia, depths of the target, and organ sites of target did not influence the accuracy of guidance using BMCPAD. The magnitude of body surface movement and organ movement exhibited mutual statistical correlation. CONCLUSIONS: The BMCPAD demonstrated guidance accuracy comparable to that of previously reported devices for CT-guided procedures. The analysis using simulated motion compensation revealed that body motion compensation and organ motion compensation individually impact the improvement in the accuracy of device-guided cryotherapy probe alignment. Considering the correlation between body and organ movements, we also determined that body motion compensation using the ring fiducial markers in the BMCPAD can be solely used to address both body and organ motions in MRI-guided cryotherapy.


Assuntos
Marcadores Fiduciais , Imageamento por Ressonância Magnética , Crioterapia , Humanos , Movimento (Física) , Estudos Retrospectivos
4.
J Vasc Interv Radiol ; 25(9): 1449-55, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24906627

RESUMO

PURPOSE: To assess safety and effectiveness of percutaneous image-guided cryoablation of hepatic tumors adjacent to the gallbladder. MATERIALS AND METHODS: Twenty-one cryoablation procedures were performed to treat 19 hepatic tumors (mean size, 2.7 cm; range, 1.0-5.0 cm) adjacent to the gallbladder in 17 patients (11 male; mean age, 59.2 y; range, 40-82 y) under computed tomography (n = 15) or magnetic resonance imaging (n = 6) guidance in a retrospective study. All tumors (mean size, 2.67 cm; range, 1.0-5.0 cm) were within 1 cm (mean, 0.4 cm) of the gallbladder; seven (33%) were contiguous with the gallbladder. Primary outcomes included complication rate and severity and postprocedure gallbladder imaging findings. Secondary outcomes included technical success and technique effectiveness at 6 months. RESULTS: Complications occurred in six of 21 procedures (29%); one (5%) was severe. Ice balls extended into the gallbladder lumen in 20 of 21 procedures (95%); no gallbladder-related complications occurred. The most common gallbladder imaging finding was mild, asymptomatic focal wall thickening after nine of 21 procedures (42%), which resolved on follow-up. Technical success was achieved in 19 of 21 sessions (90%). Six-month follow-up was available for 16 tumors; of these, all but two (87%) had no imaging evidence of local tumor progression. CONCLUSIONS: Percutaneous cryoablation of hepatic tumors adjacent to the gallbladder can be performed safely and successfully. Although postprocedural gallbladder changes are common, they are self-limited and clinically inconsequential, even when the ice ball extends into the gallbladder lumen.


Assuntos
Carcinoma Hepatocelular/cirurgia , Criocirurgia/métodos , Vesícula Biliar/lesões , Neoplasias Hepáticas/cirurgia , Complicações Pós-Operatórias/prevenção & controle , Adulto , Idoso , Idoso de 80 Anos ou mais , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/patologia , Criocirurgia/efeitos adversos , Feminino , Vesícula Biliar/patologia , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/secundário , Imagem por Ressonância Magnética Intervencionista , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/diagnóstico , Radiografia Intervencionista/métodos , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Carga Tumoral
5.
J Magn Reson Imaging ; 37(2): 407-13, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23023832

RESUMO

PURPOSE: To evaluate the value of subtraction images when using MRI to assess liver tumors treated with percutaneous ablation. MATERIALS AND METHODS: Following percutaneous ablation of 35 liver tumors, two abdominal radiologists, blinded to outcomes, independently reviewed follow-up MRI examinations for tumoral enhancement suggestive of residual/recurrent tumor and rated their confidence level. After one year, the readers reviewed the same examinations with added subtraction images. Accuracy of the detection of residual/recurrent tumor and contrast-to-noise ratios (CNR; for tumoral enhancement-to-liver, tumoral enhancement-to-ablation zone, and ablation zone-to-liver) were calculated with and without subtraction images and compared using Wilcoxon signed rank test. Interobserver variability was computed using Kappa (κ) statistics. RESULTS: Residual/recurrent tumor was present in 8 (23.5%) of 34 tumors. Accuracy of detecting residual/recurrent tumor with subtraction images and interobserver agreement (κ = 0.72, good) were better than accuracy of detecting residual/recurrent tumor and interobserver agreement (κ = 0.57, moderate) of enhanced MR images without subtraction. Mean CNR of subtraction images was significantly higher than that of enhanced MR images for tumoral enhancement-to-liver (0.2 ± 5 versus 11.6 ± 14.4, P = 0.03), tumoral enhancement-to-ablation zone (10.1 ± 12.5 versus 34.4 ± 29.4, P = 0.02), and ablation zone-to-liver (11.8 ± 13.3 versus 102.5 ± 238.4, P = 0.03). CONCLUSION: When using MRI, subtraction images help both detect and exclude residual/recurrent tumor following percutaneous liver ablations.


Assuntos
Criocirurgia/métodos , Neoplasias Hepáticas/patologia , Neoplasias Hepáticas/cirurgia , Recidiva Local de Neoplasia/patologia , Recidiva Local de Neoplasia/prevenção & controle , Técnica de Subtração , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Neoplasia Residual/patologia , Neoplasia Residual/prevenção & controle , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Método Simples-Cego , Resultado do Tratamento
6.
Acad Radiol ; 12(4): 444-50, 2005 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-15831417

RESUMO

RATIONALE AND OBJECTIVES: Accurate and reproducible segmentations of two-dimensional images are an important prerequisite for assessing tumor ablations three dimensionally (3D). We evaluated whether supervised learning methods would improve multiperformer repeated segmentations of magnetic resonance images (MRI) obtained before and after MRI-guided cryotherapy of renal cell carcinoma. MATERIALS AND METHODS: Three medical students independently performed five manual segmentations of a biopsy-proven renal cell carcinoma that was treated with percutaneous MRI-guided cryotherapy. Using pretreatment (T2-weighted fast recovery fast spin echo [FRFSE]) and posttreatment (T1-weighted, fat-suppressed, dynamically enhanced) MRIs, regions of tumor cryonecrosis were segmented. The same tasks were repeated after an experienced abdominal radiologist provided supervised learning. Segmentation sensitivity was compared with an estimated 3D-ground truth via voxel counts for regions of tumor, both before and after treatment, and for the regions of cryonecrosis. The sensitivity of each repeated segmentation was compared against the estimated ground truth using sensitivity, overlap index, and volume (mL). RESULTS: Supervised learning significantly improved posttreatment segmentation sensitivity (P = .03). With supervised learning, the ranges of the performance metrics over the segmentation performers were: pretreated tumor, sensitivity 0.902-0.999, overlap index 0.935-0.961, and volume 19.15-23.71 mL; posttreated tumor, sensitivity 0.923-0.991, overlap index 0.952-0.981, and volume 20.67-22.70 mL; in the ablation zone, sensitivity 0.938-0.969, overlap index 0.940-0.962, and volume 31.79-32.36 mL. CONCLUSIONS: Supervised learning improved multiperformer repeated segmentations of MRIs obtained before and after MRI-guided percutaneous cryotherapy of renal cell carcinoma. These methods may prove useful in aiding the 3D assessment of percutaneous tumor ablations.


Assuntos
Carcinoma de Células Renais/terapia , Crioterapia/métodos , Imageamento Tridimensional , Neoplasias Renais/terapia , Imageamento por Ressonância Magnética/métodos , Idoso , Biópsia por Agulha/métodos , Carcinoma de Células Renais/patologia , Seguimentos , Humanos , Neoplasias Renais/patologia , Masculino , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade
7.
AJR Am J Roentgenol ; 183(3): 707-12, 2004 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-15333359

RESUMO

OBJECTIVE: We report our initial investigation of the use of a 3D method for assessing percutaneous tumor ablations. We hypothesized that these 3D techniques could be used to assess the technical success of ablations and that 3D metrics would be predictive of treatment response. CONCLUSION: Three-dimensional assessment of percutaneous tumor ablations provides a quantitative evaluation of the technical success of the procedure. Three-dimensional computer-based techniques can both quantify coverage of a tumor and create a virtual ablation margin for percutaneous procedures, akin to a surgical margin. Although results are preliminary, 3D metrics were useful in predicting treatment response.


Assuntos
Criocirurgia/métodos , Neoplasias Hepáticas/patologia , Neoplasias Hepáticas/cirurgia , Imageamento por Ressonância Magnética , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Humanos , Neoplasias Hepáticas/secundário , Masculino , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA