Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
EuroIntervention ; 17(18): 1498-1505, 2022 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-34647890

RESUMO

BACKGROUND: Fractional flow reserve (FFR)-guided percutaneous coronary intervention (PCI) is superior to angiography-guided PCI. The clinical uptake of FFR has been limited, however, by the need to advance a wire in the coronary artery, the additional time required and the need for hyperaemic agents which can cause patient discomfort. FFR derived from routine coronary angiography eliminates these issues. AIMS: The aim of this study was to assess the diagnostic performance and accuracy of three-dimensional quantitative coronary angiography (3D-QCA)-based vessel FFR (vFFR) compared to pressure wire-based FFR (≤0.80). METHODS: The FAST II (Fast Assessment of STenosis severity) study was a prospective observational multicentre study designed to evaluate the diagnostic accuracy of vFFR compared to the reference standard (pressure wire-based FFR ≤0.80). A total of 334 patients from six centres were enrolled. Both site-determined and blinded independent core lab vFFR measurements were compared to FFR. RESULTS: The core lab vFFR was 0.83±0.09 and pressure wire-based FFR 0.83±0.08. A good correlation was found between core lab vFFR and pressure wire-based FFR (R=0.74; p<0.001; mean bias 0.0029±0.0642). vFFR had an excellent diagnostic accuracy in identifying lesions with an invasive wire-based FFR ≤0.80 (area under the curve [AUC] 0.93; 95% confidence interval [CI]: 0.90-0.96; p<0.001). Positive predictive value, negative predictive value, diagnostic accuracy, sensitivity and specificity of vFFR were 90%, 90%, 90%, 81% and 95%, respectively. CONCLUSIONS: 3D-QCA-based vFFR has excellent diagnostic performance to detect FFR ≤0.80. The study was registered on clinicaltrials.gov under identifier NCT03791320.


Assuntos
Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Intervenção Coronária Percutânea , Constrição Patológica , Angiografia Coronária/métodos , Estenose Coronária/diagnóstico , Vasos Coronários/diagnóstico por imagem , Humanos , Valor Preditivo dos Testes , Estudos Prospectivos , Índice de Gravidade de Doença
2.
JACC Cardiovasc Interv ; 12(24): 2449-2459, 2019 12 23.
Artigo em Inglês | MEDLINE | ID: mdl-31857014

RESUMO

OBJECTIVES: This study investigated whether left ventricular (LV) stimulation via a guidewire-reduced procedure duration while maintaining efficacy and safety compared with standard right ventricular (RV) stimulation. BACKGROUND: Rapid ventricular pacing is necessary to ensure cardiac standstill during transcatheter aortic valve replacement (TAVR). METHODS: This is a prospective, multicenter, single-blinded, superiority, randomized controlled trial. Patients undergoing transfemoral TAVR with a SAPIEN valve (Edwards Lifesciences, Irvine, California) were allocated to LV or RV stimulation. The primary endpoint was procedure duration. Secondary endpoints included efficacy, safety, and cost at 30 days. RESULTS: Between May 2017 and May 2018, 307 patients were randomized, but 4 were excluded because they did not receive the intended treatment: 303 patients were analyzed in the LV (n = 151) or RV (n = 152) stimulation groups. Mean procedure duration was significantly shorter in the LV stimulation group (48.4 ± 16.9 min vs. 55.6 ± 26.9 min; p = 0.0013), with a difference of -0.12 (95% confidence interval: -0.20 to -0.05) in the log-transformed procedure duration (p = 0.0012). Effective stimulation was similar in the LV and RV stimulation groups: 124 (84.9%) versus 128 (87.1%) (p = 0.60). Safety of stimulation was also similar in the LV and RV stimulation groups: procedural success occurred in 151 (100%) versus 151 (99.3%) patients (p = 0.99); 30-day MACE-TAVR (major adverse cardiovascular event-transcatheter aortic valve replacement) occurred in 21 (13.9%) versus 26 (17.1%) patients (p = 0.44); fluoroscopy time (min) was lower in the LV stimulation group (13.48 ± 5.98 vs. 14.60 ± 5.59; p = 0.02), as was cost (€18,807 ± 1,318 vs. €19,437 ± 2,318; p = 0.001). CONCLUSIONS: Compared with RV stimulation, LV stimulation during TAVR was associated with significantly reduced procedure duration, fluoroscopy time, and cost, with similar efficacy and safety. (Direct Left Ventricular Rapid Pacing Via the Valve Delivery Guide-wire in TAVR [EASY TAVI]; NCT02781896).


Assuntos
Valva Aórtica/cirurgia , Cateterismo Cardíaco/instrumentação , Cateteres Cardíacos , Estimulação Cardíaca Artificial , Próteses Valvulares Cardíacas , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter/instrumentação , Função Ventricular Esquerda , Função Ventricular Direita , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/economia , Cateteres Cardíacos/economia , Estimulação Cardíaca Artificial/efeitos adversos , Estimulação Cardíaca Artificial/economia , Redução de Custos , Análise Custo-Benefício , Feminino , França , Próteses Valvulares Cardíacas/economia , Custos Hospitalares , Humanos , Masculino , Duração da Cirurgia , Marca-Passo Artificial/economia , Estudos Prospectivos , Doses de Radiação , Exposição à Radiação/prevenção & controle , Fatores de Risco , Método Simples-Cego , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/economia , Resultado do Tratamento
3.
J Am Coll Cardiol ; 73(4): 444-453, 2019 02 05.
Artigo em Inglês | MEDLINE | ID: mdl-30704577

RESUMO

BACKGROUND: Physicians are not always comfortable deferring treatment of a stenosis in the left anterior descending (LAD) artery because of the perception that there is a high risk of major adverse cardiac events (MACE). The authors describe, using the DEFINE-FLAIR (Functional Lesion Assessment of Intermediate Stenosis to Guide Revascularisation) trial, MACE rates when LAD lesions are deferred, guided by physiological assessment using fractional flow reserve (FFR) or the instantaneous wave-free ratio (iFR). OBJECTIVES: The purpose of this study was to establish the safety of deferring treatment in the LAD using FFR or iFR within the DEFINE-FLAIR trial. METHODS: MACE rates at 1 year were compared between groups (iFR and FFR) in patients whose physiological assessment led to LAD lesions being deferred. MACE was defined as a composite of cardiovascular death, myocardial infarction (MI), and unplanned revascularization at 1 year. Patients, and staff performing follow-up, were blinded to whether the decision was made with FFR or iFR. Outcomes were adjusted for age and sex. RESULTS: A total of 872 patients had lesions deferred in the LAD (421 guided by FFR, 451 guided by iFR). The event rate with iFR was significantly lower than with FFR (2.44% vs. 5.26%; adjusted HR: 0.46; 95% confidence interval [CI]: 0.22 to 0.95; p = 0.04). This was driven by significantly lower unplanned revascularization with iFR and numerically lower MI (unplanned revascularization: 2.22% iFR vs. 4.99% FFR; adjusted HR: 0.44; 95% CI: 0.21 to 0.93; p = 0.03; MI: 0.44% iFR vs. 2.14% FFR; adjusted HR: 0.23; 95% CI: 0.05 to 1.07; p = 0.06). CONCLUSIONS: iFR-guided deferral appears to be safe for patients with LAD lesions. Patients in whom iFR-guided deferral was performed had statistically significantly lower event rates than those with FFR-guided deferral.


Assuntos
Estenose Coronária/complicações , Vasos Coronários/diagnóstico por imagem , Reserva Fracionada de Fluxo Miocárdico , Idoso , Angiografia Coronária , Estenose Coronária/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Revascularização Miocárdica
7.
Arch Cardiovasc Dis ; 106(6-7): 357-65, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23806304

RESUMO

BACKGROUND: Owing to the heterogeneous population of patients with acute coronary syndromes (ACS), risk stratification with tools such as the GRACE risk score is recommended to guide therapeutic management and improve outcome. AIM: To evaluate whether anaemia refines the value of the GRACE risk model to predict midterm outcome after an ACS. METHODS: A prospective registry of 1064 ACS patients (63 ± 14 years; 73% men; 57% ST-segment elevation myocardial infarction [MI]) was studied. Anaemia was defined as haemoglobin less than 13 mg/dL in men or less than 12 mg/dL in women. The primary endpoint was 6-month death or rehospitalization for MI. RESULTS: The primary endpoint was reached in 132 patients, including 68 deaths. Anaemia was associated with adverse clinical outcomes (hazard ratio 3.008, 95% confidence interval 2.137-4.234; P<0.0001) in univariate analysis and remained independently associated with outcome after adjustment for the Global Registry of Acute Coronary Events (GRACE) risk score (hazard ratio 2.870, 95% confidence interval 1.815-4.538; P<0.0001). Anaemia provided additional prognostic information to the GRACE score as demonstrated by a systematic improvement in global model fit and discrimination (c-statistic increasing from 0.633 [0.571;0.696] to 0.697 [0.638;0.755]). Subsequently, adding anaemia to the GRACE score led to reclassification of 595 patients into different risk categories; 16.5% patients at low risk (≤ 5% risk of death or rehospitalization for MI) were upgraded to intermediate (>5-10%) or high risk (>10%); 79.5% patients at intermediate risk were reclassified as low (55%) or high risk (24%); and 45.5% patients at high risk were downgraded to intermediate risk. Overall, 174 patients were reclassified into a higher risk category (17.3%) and 421 into a lower risk category (41.9%). CONCLUSION: Anaemia provides independent additional prognostic information to the GRACE score. Combining anaemia with the GRACE score refines its predictive value, which often overestimates the risk.


Assuntos
Síndrome Coronariana Aguda/complicações , Anemia/complicações , Indicadores Básicos de Saúde , Infarto do Miocárdio/etiologia , Síndrome Coronariana Aguda/sangue , Síndrome Coronariana Aguda/diagnóstico , Síndrome Coronariana Aguda/mortalidade , Síndrome Coronariana Aguda/terapia , Idoso , Anemia/sangue , Anemia/diagnóstico , Anemia/mortalidade , Anemia/terapia , Biomarcadores/sangue , Distribuição de Qui-Quadrado , Comorbidade , Intervalo Livre de Doença , Feminino , França , Hemoglobinas/análise , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Infarto do Miocárdio/sangue , Infarto do Miocárdio/diagnóstico , Infarto do Miocárdio/mortalidade , Infarto do Miocárdio/terapia , Readmissão do Paciente , Modelos de Riscos Proporcionais , Estudos Prospectivos , Sistema de Registros , Medição de Risco , Fatores de Risco , Centros de Atenção Terciária , Fatores de Tempo
8.
J Invasive Cardiol ; 22(9): 453-5, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20814056

RESUMO

A 64-year-old male with an ongoing acute coronary syndrome was treated percutaneously for a subtotal occlusion of a first diagonal branch. After predilatation of the diagonal, an important secondary branch was evident at the level of the subocclusion. A jailed wire was placed in this vessel, and stenting of the main diagonal branch was performed with a last-generation thin-strut bare cobalt-chromium stent. Conventional retrieval of the jailed wire was impossible, as the distal tip of the wire remained entrapped at the level of the stent. The strong pulling of the wire led only to a deep intubation of the guiding catheter with possible risk of dissection. Retrieval of the wire was finally possible with the support of an over-the-wire microcatheter. However, the stent, though still patent, appeared deformed. At a scheduled control angiogram 4 months later (while the patient was still asymptomatic), an optical coherence tomography (OCT) investigation of the stented segment confirmed the deformation of the stent. OCT showed a complete lack of stent struts on the side of origin of the secondary branch and an "overlap" or "accumulation" of several layers of stent struts on the other side. There were no signs of uncovered struts overall nor malapposition, and even the sites where multiple stent layers were visible were completely covered by neointimal hyperplasia. Despite the multiple layers of metal, the neointimal reaction was moderate and did not lead to a flow-limiting stenosis, thus the patient was further treated medically without the need for a new intervention.


Assuntos
Síndrome Coronariana Aguda/terapia , Angioplastia Coronária com Balão/efeitos adversos , Remoção de Dispositivo/efeitos adversos , Stents/efeitos adversos , Tomografia de Coerência Óptica , Síndrome Coronariana Aguda/diagnóstico por imagem , Síndrome Coronariana Aguda/patologia , Angioplastia Coronária com Balão/instrumentação , Ligas de Cromo , Angiografia Coronária , Humanos , Masculino , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA