Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Eur Heart J Cardiovasc Imaging ; 20(3): 361-366, 2019 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-30085055

RESUMO

AIMS: Myocardial salvage following treatment for ST-segment elevation myocardial infarction is prognostic for morbidity and mortality. Studies with myocardial salvage as endpoint rely on valid assessment of the myocardial area at risk (AAR). T2-weighted cardiovascular magnetic resonance (CMR) imaging is the preferred method to assess the AAR. However, T2-weighted imaging can be of poor image quality and uninterpretable. Contrast-enhanced (CE) cine imaging can also show AAR and our aim was to investigate if CE-cine can replace T2-weighted imaging. Cine imaging is part of a standard CMR-protocol and implementing CE-cine imaging for assessment of the AAR would mean shorter investigation time. METHODS AND RESULTS: As a DANAMI-3 substudy, we performed successful dual imaging of the AAR in 166 participants using both T2-weighted short tau inversion recovery (T2-STIR) and CE-cine imaging. T2-STIR imaging was non-diagnostic in nine and CE-cine in one scan during the period. CE-cine measured 4.7% of left ventricle (LV) [95% confidence interval 3.2-6.2%] smaller AAR compared with T2-STIR images (P < 0.001). Visual analysis of a plot of infarct size vs. AAR showed an overestimation of the AAR when measured with T2-STIR images. There was no difference in AAR with CE-cine in an interobserver analysis of 46 scans [1.2 g (standard deviation 9.5), P = 0.42]. CONCLUSIONS: CE-cine imaging shows good internal consistency in assessment of the AAR. A visual inspection reveals possible overestimation of AAR with T2-STIR images. There is good interobserver agreement in the analysis of CE-cine imaging. CE-cine can replace T2-STIR imaging resulting in a more valid assessment of the myocardial AAR.


Assuntos
Angioplastia Coronária com Balão/métodos , Interpretação de Imagem Assistida por Computador , Imagem Cinética por Ressonância Magnética/métodos , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico por imagem , Infarto do Miocárdio com Supradesnível do Segmento ST/terapia , Idoso , Meios de Contraste , Edema Cardíaco/diagnóstico por imagem , Edema Cardíaco/fisiopatologia , Feminino , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Prognóstico , Medição de Risco , Infarto do Miocárdio com Supradesnível do Segmento ST/mortalidade , Índice de Gravidade de Doença , Taxa de Sobrevida , Resultado do Tratamento
2.
Int J Cardiovasc Imaging ; 34(5): 777-786, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29168055

RESUMO

Right ventricular (RV) and left ventricular (LV) diastolic stiffness may be independent contributors to disease progression in pulmonary arterial hypertension (PAH). The aims of this study are to assess reproducibility of peak emptying rate (PER) and early diastolic peak filling rate (PFR) for both the RV and the LV in PAH and study their relationship to stroke volume (SV). Triple weekly repetition of 20 (totalling 60) cardiovascular magnetic resonance (CMR) scans, were done on 10 patients with PAH and 10 healthy controls. RV and LV volumes were measured over the full cardiac cycle. PER and PFR were calculated as the first derivative of the time-volume relationship in both the RV and the LV and indexed to body surface area. Reproducibility and the relation to SV were studied in a mixed model. PFR was lower in PAH in both the RV (PAH = 170 mL/m2/s, controls = 236 mL/m2/s [p < 0.01]) and in the LV (PAH = 209 mL/m2/s, controls = 311 mL/m2/s [p < 0.01]). PERs were not significantly different between patients and controls. Reproducibility of PER and PFR was high. A trial targeting normalization of PFR requires a total sample size of < 20. PER and PFR in both ventricles were strongly associated with stroke volume (all four: p < 0.01). Biventricular diastolic dysfunctions are strongly associated with stroke volume, and CMR can quantify them with high reproducibility, enabling small sample sizes for trials of therapies targeting diastolic dysfunction to increase survival.


Assuntos
Pressão Arterial , Hipertensão Pulmonar/complicações , Imagem Cinética por Ressonância Magnética , Artéria Pulmonar/fisiopatologia , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Direita/diagnóstico por imagem , Função Ventricular Esquerda , Função Ventricular Direita , Adulto , Estudos de Casos e Controles , Diástole , Feminino , Humanos , Hipertensão Pulmonar/diagnóstico , Hipertensão Pulmonar/fisiopatologia , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Sístole , Disfunção Ventricular Esquerda/etiologia , Disfunção Ventricular Esquerda/fisiopatologia , Disfunção Ventricular Direita/etiologia , Disfunção Ventricular Direita/fisiopatologia
3.
Eur J Heart Fail ; 19(12): 1712-1720, 2017 12.
Artigo em Inglês | MEDLINE | ID: mdl-28597481

RESUMO

AIM: Population-based European studies of peripartum cardiomyopathy (PPCM) are few. We aimed to estimate the nationwide incidence and outcome of PPCM in Denmark during 2005-2014. METHODS AND RESULTS: The Danish National Birth Register and the Danish National Patient Register were linked and searched for cardiomyopathy and heart failure ICD-10 diagnoses in a period of nine months before to 12 months after a delivery from 1 January 2005 through 31 December 2014. Diagnoses were validated and additional data were extracted from patient charts. A total of 61 women met the inclusion criteria equalling 1 in 10 149 deliveries. The majority recovered left ventricular systolic function within one year, but 14.8% suffered a major adverse event with 3.3% mortality, 8.2% mechanical circulatory support requirement and/or heart transplantation and 4.9% persistent severe heart failure. Half of the women had a concomitant hypertensive disorder of pregnancy, and this subgroup had a milder course of the disease. Baseline left ventricular ejection fraction (LVEF) was the only significant predictor of LVEF 10-14 months after diagnosis, and cabergoline therapy to inhibit lactation predicted the dichotomous outcome of complete recovery (LVEF ≥55%). CONCLUSION: The first validated, population-based European estimate of PPCM incidence is 1 in 10 149 deliveries, which places Denmark between American and Japanese estimates. Clinical outcome in the cohort was similar to those reported in recent cohorts. Women with concomitant hypertensive disorder of pregnancy had a milder course of PPCM. Baseline LVEF predicted LVEF 10-14 months after diagnosis and cabergoline predicted complete recovery.


Assuntos
Cardiomiopatias/epidemiologia , Gerenciamento Clínico , Período Periparto , Vigilância da População , Complicações Cardiovasculares na Gravidez/epidemiologia , Sistema de Registros , Função Ventricular Esquerda/fisiologia , Adulto , Cardiomiopatias/diagnóstico , Cardiomiopatias/fisiopatologia , Causas de Morte/tendências , Dinamarca/epidemiologia , Feminino , Humanos , Incidência , Gravidez , Complicações Cardiovasculares na Gravidez/diagnóstico , Complicações Cardiovasculares na Gravidez/fisiopatologia , Recuperação de Função Fisiológica , Estudos Retrospectivos
4.
Circ Cardiovasc Imaging ; 9(10)2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27729358

RESUMO

Several cardiac imaging modalities are able to visualize the left atrium (LA) and, therefore, allow for quantification of both structural and functional properties of this cardiac chamber. In echocardiography, only the maximal LA volume is included in the assessment of diastolic function at the current moment. Numerous studies, however, have shown that functional measures may be superior to the maximal LA volume in several aspects and to possess clinical value even in the absence of structural abnormalities. Such functional measures could prove particularly useful in the setting of predicting atrial fibrillation, which will be a point of focus in this review. Pivotal cardiac magnetic resonance imaging studies have revealed high correlation between LA fibrosis and risk of atrial fibrillation recurrence after catheter ablation, and subsequent multimodality imaging studies have uncovered an inverse relationship between LA reservoir function and degree of LA fibrosis. This has sparked an increased interest into the application of advanced imaging modalities, including both speckle tracking echocardiography and tissue tracking by cardiac magnetic resonance imaging. Even though increasing evidence has supported the use of functional measures and proven its superiority to the maximal LA volume, they have still not been adopted in clinical guidelines. The reason for this discrepancy may rely on the fact that there is little to no agreement on how to technically perform deformation analysis of the LA. Such technical considerations, limitations, and alternate imaging prospects will be addressed in this review.


Assuntos
Arritmias Cardíacas/diagnóstico por imagem , Função do Átrio Esquerdo , Ecocardiografia , Átrios do Coração/diagnóstico por imagem , Imageamento por Ressonância Magnética , Imagem Multimodal/métodos , Tomografia Computadorizada por Raios X , Potenciais de Ação , Arritmias Cardíacas/patologia , Arritmias Cardíacas/fisiopatologia , Arritmias Cardíacas/cirurgia , Remodelamento Atrial , Ablação por Cateter/efeitos adversos , Fibrose , Átrios do Coração/patologia , Átrios do Coração/fisiopatologia , Átrios do Coração/cirurgia , Frequência Cardíaca , Humanos , Valor Preditivo dos Testes , Recidiva , Resultado do Tratamento
5.
Int J Cardiovasc Imaging ; 29(7): 1585-93, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23653247

RESUMO

The challenge for therapies targeting perfusion abnormalities is to identify and evaluate the region of interest. The aim of this study was to compare rest and stress myocardial perfusion measured by cardiac multi-detector computed tomography (MDCT) and cardiac magnetic resonance (CMR) imaging in patients with invasive coronary angiography demonstrated occluded vessels. Twenty-four patients with refractory angina due to occluded coronary arteries underwent perfusion imaging obtained by 320-MDCT scanner and 1.5 T MR scanner. Rest and adenosine stress images were obtained and interpreted using the modified 17-segment American Heart Association model. For the qualitative analysis, each segment was graded according to the following scoring system: 0 = no defect, 1 = hypoperfusion transmural extent <1/3, 2 = 1/3-1/2, 3 = >1/2, and 4 = infarct stigmata. In the semiquantitative analysis the perfusion was either scored 0 (normal) or 1 (abnormal). The summed rest and stress scores were calculated. MDCT and CMR had a high probability to identify perfusion defects. An excellent correlation between MDCT and CMR summed rest (r = 0.916) and stress scores (r = 0.915) was found. The interobserver reproducibility was high for MDCT and CMR images. The qualitative and semiquantitative MDCT against CMR analysis of rest and stress images showed high concordance to detect perfusion defects per vascular territory and on a per myocardial segment basis. 320-MDCT and CMR perfusion imaging can be used clinically to identify myocardial perfusion defects and potentially evaluate the effect of therapy targeting perfusion abnormalities.


Assuntos
Angina Pectoris/diagnóstico , Angiografia Coronária , Circulação Coronária , Oclusão Coronária/diagnóstico , Imagem Cinética por Ressonância Magnética , Tomografia Computadorizada Multidetectores , Imagem de Perfusão do Miocárdio/métodos , Adenosina , Idoso , Idoso de 80 Anos ou mais , Angina Pectoris/diagnóstico por imagem , Angina Pectoris/fisiopatologia , Oclusão Coronária/diagnóstico por imagem , Oclusão Coronária/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Vasodilatadores
6.
J Cardiovasc Comput Tomogr ; 6(5): 325-34, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-23040538

RESUMO

BACKGROUND: Left ventricular (LV), right ventricular (RV), and left atrial (LA) volumes and functions contain important prognostic information in ischemic heart disease. Because multidetector computed tomography (MDCT) has high spatial resolution, this method may be optimal to obtain this information. OBJECTIVE: We evaluated automated assessment for MDCT, by comparing it with cardiac magnetic resonance (CMR). METHODS: Fifty-three patients with previous myocardial infarction were scanned with 1.5 Tesla CMR and 64-slice MDCT. End-diastolic volume, end-systolic volume, stroke volume, and ejection fraction (EF) were assessed for the left and right ventricle with automatic MDCT software and manual CMR software. LV myocardial mass and cyclic changes in LA volume were derived. RESULTS: The mean age of patients was 61 ± 10 years, 40 (75%) were men. Automated MDCT segmentation was possible in all but 2 patients. The average duration of image processing was 21 ± 4 minutes by CMR and 11 ± 4 minutes by MDCT. Bland-Altman plots showed good agreement between MDCT and CMR with only small bias. LVEF by CMR was 56% ± 10% and by MDCT 61% ± 11%, mean difference of -5% (limits of agreement, -18% to 8%), and P < 0.001. RVEF by CMR was 60% ± 5% and by MDCT 56% ± 8%, mean difference of 5% (limits of agreement, -10% to 20%), and P < 0.001. LA fractional change by CMR was 49% ± 9% and by MDCT 45% ± 9%, mean difference of 4% (limits of agreement, -12% to 20%), and P ≤ 0.001. CONCLUSION: LV, RV, and LA volumes and functions may be evaluated fast and reliably with the use of automated assessment and cardiac MDCT, with good agreement to CMR. Accurate assessment of cardiac chambers with MDCT appears possible in clinical practice.


Assuntos
Volume Cardíaco , Coração/diagnóstico por imagem , Coração/fisiopatologia , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/fisiopatologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Função do Átrio Esquerdo , Feminino , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/patologia , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/patologia , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada Multidetectores , Infarto do Miocárdio/patologia , Miocárdio/patologia , Variações Dependentes do Observador , Estudos Prospectivos , Reprodutibilidade dos Testes , Função Ventricular Esquerda , Função Ventricular Direita
7.
Int J Cardiovasc Imaging ; 28(5): 1061-71, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21847562

RESUMO

Measurement of left atrial (LA) maximal volume (LA(max)) using two-dimensional transthoracic echocardiography (TTE) provides prognostic information in several cardiac diseases. However, the relationship between LA(max) and LA function is poorly understood and TTE is less well suited for measuring dynamic LA volume changes. Conversely, cardiac magnetic resonance imaging (CMR) and multi-slice computed tomography (MSCT) appears more appropriate for such measures. We sought to determine the relationship between LA size assessed with TTE and LA size and function assessed with CMR and MSCT. Fifty-four patients were examined 3 months post myocardial infarction with echocardiography, CMR and MSCT. Left atrial volumes and LA reservoir function were assessed by TTE. LA time-volume curves were determined and LA reservoir function (cyclic change and fractional change), passive emptying function (reservoir volume) and pump function (left atrial ejection fraction-LAEF) were derived using CMR and MSCT. Left atrial fractional change and left atrial ejection fraction (LAEF) determined with CMR and MSCT were unrelated to LA(max) enlargement by echocardiography (P = NS). There was an overall good agreement between CMR and MSCT, with a small to moderate bias in LA(max) (4.9 ± 10.4 ml), CC (3.1 ± 9.1 ml) and reservoir volume (3.4 ± 9.1 ml). TTE underestimates LA(max) with up to 32% compared with CMR and MSCT (P < 0.001). Left atrial function assessed with MSCT and CMR as LA fractional change and LAEF is not significantly related to LA(max) measured by TTE. TTE systematically underestimated LA volumes, whereas there are good agreements between MSCT and CMR for volumetric and functional properties.


Assuntos
Função do Átrio Esquerdo , Ecocardiografia , Imageamento por Ressonância Magnética , Tomografia Computadorizada Multidetectores , Infarto do Miocárdio/diagnóstico , Idoso , Dinamarca , Feminino , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/patologia , Átrios do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/patologia , Infarto do Miocárdio/fisiopatologia , Variações Dependentes do Observador , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA