Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Eur J Cardiothorac Surg ; 65(1)2024 Jan 02.
Artigo em Inglês | MEDLINE | ID: mdl-37756697

RESUMO

OBJECTIVES: This population-based cohort study investigated mid-term outcome after surgical aortic valve replacement with a bioprosthetic or mechanical valve prosthesis in patients aged <50 years in a European social welfare state. METHODS: We analysed patient data from the main social insurance carriers in Austria (2010-2020). Subsequent patient-level record linkage with national health data provided patient characteristics and clinical outcome. Survival, reoperation, myocardial infarction, heart failure, embolic stroke or intracerebral haemorrhage, bleeding other than intracerebral haemorrhage and major adverse cardiac events were evaluated as outcomes. RESULTS: A total of 991 patients were analysed. Regarding demographics, no major differences between groups were observed. Multivariable Cox regression revealed no significant difference in overall survival (P = 0.352) with a median follow-up time of 6.2 years. Reoperation-free survival was decreased (hazard ratio = 1.560 [95% CI: 1.076-2.262], P = 0.019) and the risk for reoperation was increased (hazard ratio = 2.770 [95% CI: 1.402-5.472], P = 0.003) in patients who received bioprostheses. Estimated probability of death after reoperation was 0.23 (CL: 0.08-0.35) after 2 years and 0.34 (CL: 0.06-0.53) after 10 years over both groups. Regarding further outcomes, no significant differences between the two groups were observed. CONCLUSIONS: In patients below 50 years of age receiving aortic valve replacement, implantation of bioprostheses when compared to mechanical heart valve prostheses was associated with a significantly higher rate of reoperations and reduced reoperation-free survival. Nevertheless, we could not observe a difference in overall survival. However, long-term follow-up has to evaluate that a significantly lower rate of reoperations may translate in consistently improved long-term survival.


Assuntos
Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Humanos , Pessoa de Meia-Idade , Próteses Valvulares Cardíacas/efeitos adversos , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Estudos de Coortes , Desenho de Prótese , Reoperação , Bioprótese/efeitos adversos , Hemorragia Cerebral/etiologia , Pontuação de Propensão , Resultado do Tratamento , Estudos Retrospectivos , Falha de Prótese
2.
J Cardiothorac Vasc Anesth ; 38(2): 445-450, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38129207

RESUMO

OBJECTIVES: It remains unclear whether intraoperative lung-protective strategies can reduce the rate of respiratory complications after cardiac surgery, partly because low-risk patients have been studied in the past. The authors established a screening model to easily identify a high-risk group for severe pulmonary complications (ie, pneumonia or acute respiratory distress syndrome) that may be the ideal target population for the assessment of the potential benefits of such measures. DESIGN: Retrospective observational trial. SETTING: Departments of cardiac surgery and cardiac anesthesia of a university hospital. PARTICIPANTS: Consecutive patients undergoing cardiac surgery on cardiopulmonary bypass and subsequent treatment at a dedicated cardiosurgical intensive care unit between January 2019 and March 2021. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Of the 2,572 patients undergoing surgery, 84 (3.3%) developed pneumonia/acute respiratory distress syndrome that significantly affected the outcome (ie, longer ventilatory support [66% vs 11%], higher reintubation rate [39% vs 3%]), prolonged length of intensive care unit [33 ± 36 vs 4 ± 10 days] and hospital stay [10 ± 15 vs 6 ± 7 days], and higher in-hospital [43% vs 9%] as well as 30-day [7% vs 3%] mortality). The screening model for severe pulmonary complications included left ventricular ejection fraction <52%, EuroSCORE II (European System for Cardiac Operative Risk Evaluation II) >5.9, cardiopulmonary bypass time >123 minutes, left ventricular assist device or aortic repair surgery, and bronchodilatory therapy. A cutoff for the predicted risk of 2.5% showed optimal sensitivity and specificity, with an area under the receiver operating characteristic curve of 0.82. CONCLUSIONS: The authors suggest that future research on intraoperative lung-protective measures focuses on this high-risk population, primarily aiming to mitigate severe forms of postoperative pulmonary dysfunction associated with poor outcomes and increased resource consumption.


Assuntos
Pneumonia , Síndrome do Desconforto Respiratório , Humanos , Estudos Retrospectivos , Volume Sistólico , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Função Ventricular Esquerda , Pulmão , Síndrome do Desconforto Respiratório/etiologia , Pneumonia/complicações
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA