Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Ann Thorac Surg ; 97(1): 71-7, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24090576

RESUMO

BACKGROUND: The basis of mitral annuloplasty ring design has progressed from qualitative surgical intuition to experimental and theoretical analysis of annular geometry with quantitative imaging techniques. In this work, we present an automated three-dimensional (3D) echocardiographic image analysis method that can be used to statistically assess variability in normal mitral annular geometry to support advancement in annuloplasty ring design. METHODS: Three-dimensional patient-specific models of the mitral annulus were automatically generated from 3D echocardiographic images acquired from subjects with normal mitral valve structure and function. Geometric annular measurements including annular circumference, annular height, septolateral diameter, intercommissural width, and the annular height to intercommissural width ratio were automatically calculated. A mean 3D annular contour was computed, and principal component analysis was used to evaluate variability in normal annular shape. RESULTS: The following mean ± standard deviations were obtained from 3D echocardiographic image analysis: annular circumference, 107.0 ± 14.6 mm; annular height, 7.6 ± 2.8 mm; septolateral diameter, 28.5 ± 3.7 mm; intercommissural width, 33.0 ± 5.3 mm; and annular height to intercommissural width ratio, 22.7% ± 6.9%. Principal component analysis indicated that shape variability was primarily related to overall annular size, with more subtle variation in the skewness and height of the anterior annular peak, independent of annular diameter. CONCLUSIONS: Patient-specific 3D echocardiographic-based modeling of the human mitral valve enables statistical analysis of physiologically normal mitral annular geometry. The tool can potentially lead to the development of a new generation of annuloplasty rings that restore the diseased mitral valve annulus back to a truly normal geometry.


Assuntos
Simulação por Computador , Ecocardiografia Tridimensional/métodos , Valva Mitral/anatomia & histologia , Valva Mitral/diagnóstico por imagem , Humanos , Interpretação de Imagem Assistida por Computador , Valva Mitral/cirurgia , Anuloplastia da Valva Mitral/métodos , Modelos Anatômicos , Valores de Referência , Estatística como Assunto
2.
J Heart Valve Dis ; 23(6): 713-20, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25790618

RESUMO

BACKGROUND AND AIM OF THE STUDY: Ischemic mitral regurgitation (IMR), the incidence of which is increasing, results from annular and subvalvular remodeling after myocardial infarction (MI). Although a sheep model of IMR has been used extensively over the past two decades, the ventricular, coronary and leaflet anatomy in sheep is significantly different from that in humans. In contrast, pigs are more similar to humans with regard to these parameters, and therefore may serve as a better animal to test emerging new technologies designed to treat IMR. METHODS: Twenty-nine pigs (body weight 30-35 kg) underwent left thoracotomy and ligation of the mid main circumflex and distal right posterior descending coronary arteries to create a posterolateral MI. Of these pigs, 18 were used for acute data acquisition, while 11 surviving animals in the chronic group were assessed at eight weeks after MI. Real-time three-dimensional echocardiography was performed at baseline, and at 30 min and eight weeks after MI, to assess geometric changes in the mitral annulus, mitral leaflets and left ventricle. RESULTS: Compared to baseline, the MR grade was increased significantly at eight weeks (0.7 + 0.5 versus 2.0 +/- 1.2), together with a significant decrease in left ventricular ejection fraction (40.3 +/- 6.6% versus 25.8 +/- 7.7%). Significant increases were also noted at eight weeks in the commissural width (30.1 +/- 3.2 mm versus 35.1 +/- 2.9 mm) and septolateral diameter (25.0 +/- 2.0 mm versus 33.8 +/- 5.9 mm), with a resultant increase in mitral annular area (596 +/- 85 versus 931 +/- 181 mm3) and a decrease in the annular height to commissural width ratio (15.7 +/- 2.6% versus 13.7 +/- 1.9%). The mitral valve tenting volume was also increased significantly (1577 +/- 645 versus 2440 +/- 755 mm3). The distance between the papillary muscle tips at baseline and at eight weeks was increased significantly (23.9 +/- 2.5 versus 30.9 +/- 5.2 mm), as was the distance between the posterior papillary muscle tip and the posterior commissure (20.9 +/- 2.7 versus 24.1 +/- 2.8 mm). CONCLUSION: The surgical model described here reliably replicates the changes seen in humans with IMR. Hence, this model can be used for further studies of the pathophysiology of IMR, and of any novel interventions in this challenging clinical area.


Assuntos
Modelos Animais de Doenças , Insuficiência da Valva Mitral , Infarto do Miocárdio/complicações , Suínos , Animais , Ecocardiografia Tridimensional/métodos , Valva Mitral/patologia , Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/etiologia , Insuficiência da Valva Mitral/fisiopatologia , Modelos Anatômicos , Músculos Papilares/patologia , Músculos Papilares/fisiopatologia , Fatores de Tempo , Remodelação Ventricular
3.
Eur J Cardiothorac Surg ; 39(6): 875-80, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21177117

RESUMO

OBJECTIVE: The aim of the study was to evaluate survival and quality of life after mitral surgery in octogenarians. METHODS: From 1987 to 2007, 129 patients ≥ 80 years (median age 82 years; minimum 80 years and maximum 89 years) underwent mitral surgery (87.6% myxomatous, 10% rheumatic, and 2.3% ischemic) with repair procedure in 75 patients and replacement in 54 patients. In the repair and the replacement groups, respectively: Logistic EuroSCORE (European System for Cardiac Operative Risk Evaluation) was 5.77 (3.5-63) versus 11.1 (3.5-93.2); and significative preoperative differences were diabetes mellitus (1.3% vs 16.7%, p=0.002) and previous cardiac surgery (0% vs 16.7%, p=0.0001). Survival and quality of life (walking test) were assessed. RESULTS: In the repair and the replacement groups, respectively, hospital mortality (1 month) was 2.7% versus 18.5% (p=0.004). Early (1-6 months) mortality remained high with 9.6% versus 13.6% (p=0.55). Late mortality (6 months-7 years) was stable with an annual mortality of 8% versus 6% per year (p=0.32). The replacement procedure was the only significative predictor of mortality with an odds ratio (OR) of 6.7 (1.1-38.8 (p=0.04)) for operative mortality. Regarding quality of life, with 41 months' (1.1-180) (100%) follow-up, 54.2% (65.9%) of repair (replace) patients were living in a nursing home and walking distance without aid was more than 500 m in 67.1% (81.2%) of patients. CONCLUSIONS: For elderly patients, 6-month mortality better reflects the burden of mitral surgery than the usual 1-month mortality. Even though replacement patients have higher operative estimated risk, mitral replacement remains, after adjustment, an independent predictor of higher operative mortality. Our results claim for wider use of repair technique in mitral surgery for the octogenarians, even if replacement is an acceptable option when repair is technically uncertain.


Assuntos
Doenças das Valvas Cardíacas/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Valva Mitral/cirurgia , Qualidade de Vida , Fatores Etários , Idoso de 80 Anos ou mais , Métodos Epidemiológicos , Feminino , Doenças das Valvas Cardíacas/reabilitação , Implante de Prótese de Valva Cardíaca/reabilitação , Humanos , Tempo de Internação/estatística & dados numéricos , Masculino , Cuidados Pós-Operatórios/métodos , Prognóstico , Resultado do Tratamento , Caminhada/fisiologia
4.
Eur J Cardiothorac Surg ; 35(6): 970-5; discussion 975-6, 2009 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-19409805

RESUMO

OBJECTIVE: Balloon-expandable stent valves require flow reduction during implantation (rapid pacing). The present study was designed to compare a self-expanding stent valve with annular fixation versus a balloon-expandable stent valve. METHODS: Implantation of a new self-expanding stent valve with annular fixation (Symetis, Lausanne, Switzerland) was assessed versus balloon-expandable stent valve, in a modified Dynatek Dalta pulse duplicator (sealed port access to the ventricle for transapical route simulation), interfaced with a computer for digital readout, carrying a 25 mm porcine aortic valve. The cardiovascular simulator was programmed to mimic an elderly woman with aortic stenosis: 120/85 mmHg aortic pressure, 60 strokes/min (66.5 ml), 35% systole (2.8 l/min). RESULTS: A total of 450 cardiac cycles was analysed. Stepwise expansion of the self-expanding stent valve with annular fixation (balloon-expandable stent valve) resulted in systolic ventricular increase from 120 to 121 mmHg (126 to 830+/-76 mmHg)*, and left ventricular outflow obstruction with mean transvalvular gradient of 11+/-1.5 mmHg (366+/-202 mmHg)*, systolic aortic pressure dropped distal to the valve from 121 to 64.5+/-2 mmHg (123 to 55+/-30 mmHg) N.S., and output collapsed to 1.9+/-0.06 l/min (0.71+/-0.37 l/min* (before complete obstruction)). No valve migration occurred in either group. (*=p<0.05). CONCLUSIONS: Implantation of this new self-expanding stent valve with annular fixation has little impact on haemodynamics and has the potential for working heart implantation in vivo. Flow reduction (rapid pacing) is not necessary.


Assuntos
Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Pressão Sanguínea/fisiologia , Implante de Prótese de Valva Cardíaca , Hemodinâmica/fisiologia , Humanos , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Modelos Cardiovasculares , Desenho de Prótese , Stents , Pressão Ventricular/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA