Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Clin Chem ; 70(4): 669-679, 2024 04 03.
Artigo em Inglês | MEDLINE | ID: mdl-38385453

RESUMO

BACKGROUND: The harmonization status of most tumor markers (TMs) is unknown. We report a feasibility study performed to determine whether external quality assessment (EQA) programs can be used to obtain insights into the current harmonization status of the tumor markers α-fetoprotein (AFP), prostate specific antigen (PSA), carcinoembryonic antigen (CEA), cancer antigen (CA)125, CA15-3 and CA19-9. METHODS: EQA sample results provided by 6 EQA providers (INSTAND [Germany], Korean Association of External Quality Assessment Service [KEQAS, South Korea], National Center for Clinical Laboratories [NCCL, China], United Kingdom National External Quality Assessment Service [UK NEQAS, United Kingdom], Stichting Kwaliteitsbewaking Medische Laboratoriumdiagnostiek [SKML, the Netherlands], and the Royal College of Pathologists of Australasia Quality Assurance Programs [RCPAQAP, Australia]) between 2020 and 2021 were used. The consensus means, calculated from the measurement procedures present in all EQA programs (Abbott Alinity, Beckman Coulter DxI, Roche Cobas, and Siemens Atellica), was used as reference values. Per measurement procedure, the relative difference between consensus mean for each EQA sample and the mean of all patient-pool-based EQA samples were calculated and compared to minimum, desirable, and optimal allowable bias criteria based on biological variation. RESULTS: Between 19040 (CA15-3) and 25398 (PSA) individual results and 56 (PSA) to 76 (AFP) unique EQA samples were included in the final analysis. The mean differences with the consensus mean of patient-pool-based EQA samples for all measurement procedures were within the optimum bias criterion for AFP, the desirable bias for PSA, and the minimum bias criterion for CEA. However, CEA results <8 µg/L exceeded the minimum bias criterion. For CA125, CA15-3, and CA19-9, the harmonization status was outside the minimum bias criterion, with systematic differences identified. CONCLUSIONS: This study provides relevant information about the current harmonization status of 6 tumor markers. A pilot harmonization investigation for CEA, CA125, CA15-3, and CA19-9 would be desirable.


Assuntos
Biomarcadores Tumorais , Antígeno Carcinoembrionário , Masculino , Humanos , alfa-Fetoproteínas/análise , Antígeno Prostático Específico , Antígeno CA-19-9 , Estudos de Viabilidade , Mucina-1 , Antígeno Ca-125
2.
Clin Chem Lab Med ; 61(10): 1719-1729, 2023 09 26.
Artigo em Inglês | MEDLINE | ID: mdl-37071928

RESUMO

OBJECTIVES: The clinical use of soluble transferrin receptor (sTfR) as an iron status indicator is hindered by a lack of assay standardization and common reference ranges and decision thresholds. In 2009, the WHO and National Institute for Biological Standards and Controls (NIBSC) released a sTfR reference material (RM), 07/202, for assay standardization; however, a comprehensive, formal commutability study was not conducted. METHODS: This study evaluated the commutability of WHO 07/202 sTfR RM and human serum pools and the impacts of their use as common calibrators. Commutability was assessed for six different measurement procedures (MPs). Serum pools were prepared according to updated CLSI C37-A procedures (C37) or non-C37 procedures. The study design and analyses were based on Parts 2 and 3 of the 2018 IFCC Commutability in Metrological Traceability Working Group's Recommendations for Commutability Assessment. WHO 07/202 and serum pools were used for instrument/assay and mathematical recalibration, respectively, to determine if their use decreases inter-assay measurement variability for clinical samples. RESULTS: The WHO 07/202 RM dilutions were commutable for all 6 MPs assessed and, when used for instrument calibration, decreased inter-assay variability from 208 to 55.7 %. Non-C37 and C37 serum pools were commutable for all 6 MPs assessed and decreased inter-assay variability from 208 to 13.8 % and 4.6 %, respectively, when used for mathematical recalibration. CONCLUSIONS: All materials evaluated, when used as common calibrators, substantially decreased inter-assay sTfR measurement variability. MP calibration to non-C37 and C37 serum pools may reduce the sTfR IMPBR to a greater extent than WHO 07/202 RM.


Assuntos
Receptores da Transferrina , Soro , Humanos , Padrões de Referência , Calibragem , Organização Mundial da Saúde
3.
Clin Chem ; 69(3): 262-272, 2023 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-36644921

RESUMO

BACKGROUND: Elevated concentrations of lipoprotein(a) [Lp(a)] are directly related to an increased risk of cardiovascular diseases, making it a relevant biomarker for clinical risk assessment. However, the lack of global standardization of current Lp(a) measurement procedures (MPs) leads to inconsistent patient care. The International Federation for Clinical Chemistry and Laboratory Medicine working group on quantitating apolipoproteins by mass spectrometry (MS) aims to develop a next-generation SI (International system of units)-traceable reference measurement system consisting of a MS-based, peptide-calibrated reference measurement procedure (RMP) and secondary serum-based reference materials (RMs) certified for their apolipoprotein(a) [apo(a)] content. To reach measurement standardization through this new measurement system, 2 essential requirements need to be fulfilled: a sufficient correlation among the MPs and appropriate commutability of future serum-based RMs. METHODS: The correlation among the candidate RMP (cRMP) and immunoassay-based MPs was assessed by measuring a panel of 39 clinical samples (CS). In addition, the commutability of 14 different candidate RMs was investigated. RESULTS: Results of the immunoassay-based MPs and the cRMPs demonstrated good linear correlations for the CS but some significant sample-specific differences were also observed. The results of the commutability study show that RMs based on unspiked human serum pools can be commutable with CS, whereas human pools spiked with recombinant apo(a) show different behavior compared to CS. CONCLUSIONS: The results of this study show that unspiked human serum pools are the preferred candidate secondary RMs in the future SI-traceable Lp(a) Reference Measurement System.


Assuntos
Química Clínica , Lipoproteína(a) , Humanos , Imunoensaio , Espectrometria de Massas , Padrões de Referência
4.
Prev Chronic Dis ; 16: E147, 2019 10 31.
Artigo em Inglês | MEDLINE | ID: mdl-31674304

RESUMO

Trans-fatty acid (TFA) intake can increase the risk of coronary heart disease (CHD) morbidity and mortality and all-cause mortality. Industrially produced TFAs and ruminant TFAs are the major sources in foods. TFA intake and TFA-attributed CHD mortality vary widely worldwide. Excessive TFA intake is a health threat in high-income countries; however, it is also a threat in low- and middle-income countries (LMICs). Data on TFA intake are scarce in many LMICs and an urgent need exists to monitor TFAs globally. We reviewed global TFA intake and TFA-attributed CHD mortality and current progress toward policy or regulation on elimination of industrially produced TFAs in foods worldwide. Human biological tissues can be used as biomarkers of TFAs because they reflect actual intake from various foods. Measuring blood TFA levels is a direct and reliable method to quantify TFA intake.


Assuntos
Doença das Coronárias/mortalidade , Ácidos Graxos trans/efeitos adversos , Doença Crônica/mortalidade , Saúde Global , Política de Saúde , Humanos , Fatores de Risco , Ácidos Graxos trans/administração & dosagem , Ácidos Graxos trans/sangue
5.
Am J Public Health ; 109(4): 634-636, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30789777

RESUMO

OBJECTIVES: To estimate the impact of the 2006 policy restricting use of trans fatty acids (TFAs) in New York City restaurants on change in serum TFA concentrations in New York City adults. METHODS: Two cross-sectional population-based New York City Health and Nutrition Examination Surveys conducted in 2004 (n = 212) and 2013-2014 (n = 247) provided estimates of serum TFA exposure and average frequency of weekly restaurant meals. We estimated the geometric mean of the sum of serum TFAs by year and restaurant meal frequency by using linear regression. RESULTS: Among those who ate less than 1 restaurant meal per week, geometric mean of the sum of serum TFAs declined 51.1% (95% confidence interval [CI] = 42.7, 58.3)-from 44.6 (95% CI = 39.7, 50.1) to 21.8 (95% CI = 19.3, 24.5) micromoles per liter. The decline in the geometric mean was greater (P for interaction = .04) among those who ate 4 or more restaurant meals per week: 61.6% (95% CI = 55.8, 66.7) or from 54.6 (95% CI = 49.3, 60.5) to 21.0 (95% CI = 18.9, 23.3) micromoles per liter. CONCLUSIONS: New York City adult serum TFA concentrations declined between 2004 and 2014. The indication of greater decline in serum TFAs among those eating restaurant meals more frequently suggests that the municipal restriction on TFA use was effective in reducing TFA exposure. Public Health Implications. Local policies focused on restaurants can promote nutritional improvements.


Assuntos
Política de Saúde/legislação & jurisprudência , Restaurantes/estatística & dados numéricos , Ácidos Graxos trans/sangue , Estudos Transversais , Gorduras na Dieta/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Cidade de Nova Iorque , Inquéritos Nutricionais , Ácidos Graxos trans/efeitos adversos
7.
J Nutr ; 143(6): 995S-1000S, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23596166

RESUMO

Hemoglobin adducts of acrylamide (HbAA) and glycidamide (HbGA) have been measured as biomarkers of acrylamide exposure and metabolism in a nationally representative sample of the U.S. population in the NHANES 2003-2004. We assessed the association of sociodemographic (age, sex, race-ethnicity, education, and income) and lifestyle (smoking, alcohol consumption, BMI, physical activity, and dietary supplement use) variables with these biomarkers in U.S. adults (aged ≥ 20 y). We used bivariate and multiple regression models and assessed the magnitude of an estimated change in biomarker concentration with change in a covariable for 2 biomarkers of acrylamide exposure. Smoking was strongly and significantly correlated with HbAA and HbGA concentrations (rs = 0.51 and 0.42, respectively), with biomarker concentrations being 126 and 101% higher in smokers compared with nonsmokers after adjusting for sociodemographic and lifestyle covariates. Age was moderately and significantly correlated with both biomarkers (rs = -0.21 and -0.22, respectively). BMI (rs = -0.11) and alcohol consumption (rs = 0.13) were weakly yet significantly correlated with HbAA concentrations only. The estimated percentage change in biomarker concentration was ≤ 20% for all variables other than smoking after adjusting for sociodemographic and lifestyle covariates. Using multiple regression models, the sociodemographic variables explained 9 and 7% whereas the sociodemographic and lifestyle variables together explained 46 and 25% of the variability in HbAA and HbGA, respectively, showing the importance of considering and adequately controlling for these variables in future studies. Our findings will be useful in the design and analysis of future studies that assess and evaluate exposure to acrylamide and its metabolism to glycidamide.


Assuntos
Acrilamida , Biomarcadores/sangue , Exposição Ambiental , Inquéritos Nutricionais , Fumar/sangue , Acrilamida/sangue , Acrilamida/metabolismo , Adulto , Fatores Etários , Consumo de Bebidas Alcoólicas/sangue , Compostos de Epóxi/sangue , Compostos de Epóxi/metabolismo , Feminino , Hemoglobinas/metabolismo , Humanos , Estilo de Vida , Fígado/metabolismo , Masculino , Pessoa de Meia-Idade , Análise de Regressão , Fatores Sexuais , Fatores Socioeconômicos , Estados Unidos
8.
Cancer Epidemiol Biomarkers Prev ; 16(11): 2471-8, 2007 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-18006939

RESUMO

Smoking is an important source of acrylamide exposure in the general population. We assessed the relationship between hemoglobin adducts of acrylamide (HbAA) and glycidamide (HbGA) as biomarkers of acrylamide exposure and plasma cotinine (PC) as biomarkers of tobacco smoke exposure in 94 men and 67 women. The median (5th-95th percentile) biomarker concentrations (pmol/g Hb) in the group of individuals with PC concentrations of 10 ng/mL [194 (87-403) and 107 (41-215) for HbAA and HbGA, respectively]. In individuals with PC concentrations of <1 ng/mL, HbAA and HbGA were similar to those observed in the group with PC values of 10 ng/mL. Although HbAA and HbGA could be categorized into distinguishable groups using PC concentration ranges commonly used to categorize presumed smokers and nonsmokers, no significant relationship was observed between these two biomarkers and PC within each group. The different exposure periods reflected by these biomarkers and the resulting different susceptibility to short-term variations in exposure patterns may in part explain these observations. The findings suggest that tobacco smoke exposure in individuals with PC values of <1 ng/mL has only a minimal effect on HbAA and HbGA.


Assuntos
Acrilamida/sangue , Cotinina/sangue , Compostos de Epóxi/sangue , Fumar/sangue , Adolescente , Adulto , Idoso , Biomarcadores/sangue , Feminino , Hemoglobinas/metabolismo , Humanos , Masculino , Pessoa de Meia-Idade , Nicotina/metabolismo , Fumar/efeitos adversos , Poluição por Fumaça de Tabaco
9.
J Diabetes Sci Technol ; 1(2): 153-7, 2007 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-19888399

RESUMO

Self-monitoring of blood glucose (SMBG) is an important component in diabetes management, helping patients to achieve and maintain normal blood glucose levels. The benefit of SMBG depends on the quality of the measurement performed. Therefore, it is important to know the factors affecting the measurements and to assure that the quality of SMBG measurements is at the highest achievable level possible. To accomplish this, all aspects of the measurement procedure need to be taken into consideration. Sources of variability can be related to the monitor itself, its calibration and use, including blood collection. Improving the variability caused by each source requires specifically designed and targeted efforts. Variability related to the monitor can be assessed in studies that minimize other sources of variability. Variability related to monitor calibration can be assessed and minimized through harmonization or standardization programs, while variability related to the use of the monitors can be addressed through patient-oriented assessment and training. The latter may follow procedures similar to external quality assessment (EQA) programs used in clinical laboratory medicine. However, to obtain an optimal impact on patient care, such programs need to have a wide reach and the social and cultural competency to work efficiently with all patients. The EQA approach or approaches that would provide the most benefit to the patient remain to be determined.

10.
J Diabetes Complications ; 20(5): 285-94, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16949515

RESUMO

Treatment goals for diabetic patients are directed towards lowering A1c values by controlling blood glucose concentrations (BGC), making it important to understand the relationship between the two parameters. Because findings from clinical trials about the relationship between BGC and A1c values show a profound variability around the obtained regression lines, they are difficult to apply to individual patients. Therefore, a model was developed and applied based on the kinetics of HbA1c formation and removal. It takes the instability of A1c and loss of hemoglobin into consideration. Data from clinical studies and hypothetical scenarios were used to test the model and to describe the relationship between A1c and BGC. A close agreement between experimental and calculated data was obtained in steady-state and non-steady-state conditions. Aside the erythrocyte life span, the chemical instability of A1c appears to affect A1c levels markedly and their changes due to therapy. A threefold increase in BGC over 30 days prior to A1c measurement can cause an increase in A1c value of about 120% as compared with 4% when it occurs 4 months prior to A1c measurement. Profound daily fluctuations in BGC result in minor changes in A1c. In conclusion, A1c provides information about a patient's glycemia, mainly over the past 2 months, and may not reflect well daily blood glucose fluctuations. This model might be suitable to identify individual differences in glycation rates.


Assuntos
Glicemia/metabolismo , Diabetes Mellitus/sangue , Hemoglobinas Glicadas/farmacocinética , Modelos Biológicos , Algoritmos , Produtos Finais de Glicação Avançada/metabolismo , Humanos , Modelos Químicos , Valores de Referência
11.
Diabetes Technol Ther ; 8(1): 76-80, 2006 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-16472053

RESUMO

BACKGROUND: Interstitial fluid (ISF) is a specimen of increasing interest for glucose measurements because it can be obtained in a minimally invasive manner. Our previous study showed that sufficient ISF can be obtained using microneedles to measure glucose with a conventional electrochemical glucose monitor. The aim of this study was to assess the trueness of this glucose monitor using split-sample comparison with whole blood. We used ISF as specimen and our gas chromatography/mass spectrometry (GC/MS) method as reference. METHODS: We obtained 50 ISF samples and 40 whole blood samples from hairless Sprague- Dawley rats and analyzed for glucose by both methods. RESULTS: For whole blood, a non-significant bias of 5.7% (+/-2 SD: -54.9% to 66.3%) was determined. ISF glucose measurements showed a significant constant bias of 29.5% (+/-2 SD: -85.0% to 144%), which seems to be caused in part by the lack of red blood cells in ISF. The correlation coefficients were 0.782 and 0.679 for whole blood and ISF, respectively. CONCLUSIONS: The assessed electrochemical glucose monitor shows a close agreement with our GC/MS reference method for whole blood, for which this monitor was optimized. When glucose measurements are performed with ISF as matrix, the observed bias needs to be taken into consideration. Further studies are necessary to elucidate the reasons for the wide dispersion of data for ISF.


Assuntos
Glicemia/análise , Líquido Extracelular/química , Glucose/análise , Monitorização Fisiológica/métodos , Animais , Masculino , Modelos Animais , Ratos , Ratos Sprague-Dawley , Reprodutibilidade dos Testes
12.
Rapid Commun Mass Spectrom ; 19(19): 2865-70, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-16155977

RESUMO

Enzymatic digestion of proteins and analysis of the resulting peptides by mass spectrometry is an established approach in proteomics and in clinical and environmental chemistry. The long digestion times of several hours prevent the fast turnover of samples and results. Qualitative applications showed that microwave radiation profoundly shortens enzymatic digestion. However, its usefulness for quantitative applications had not been assessed. In this study, the microwave-assisted enzymatic digestion of hemoglobin at different temperatures, buffer concentrations, and digestion times was assessed and compared with conventional digestion for the proteolytic enzymes trypsin and Glu-C. A microwave-assisted enzymatic digestion method optimized for digestion time and temperature was applied for the analysis of glycated hemoglobin HbA1c and compared with a reference method. Using trypsin, complete digestion was obtained at 50 degrees C within 20 min. Under these conditions, the digestion efficiency was 20% higher than with conventional trypsin digestion. These effects were not observed with Glu-C as enzyme, probably because of the decreased stability of Glu-C at elevated temperatures in comparison with the trypsin used. The comparison of the optimized microwave-assisted digestion method using trypsin with the reference method for HbA1c using Glu-C gave a close correlation in the results (R2: 0.996). A significant bias of 0.33% HbA1c was observed, with higher values obtained with the microwave-assisted tryptic digest; this finding might have resulted from the use of a different enzyme. This study showed that microwave-assisted enzymatic digestion can substantially reduce digestion times to minutes and can be used in qualitative as well as quantitative applications.


Assuntos
Cromatografia Gasosa-Espectrometria de Massas/métodos , Hemoglobinas Glicadas/análise , Hemoglobinas Glicadas/química , Espectrometria de Massas , Micro-Ondas , Serina Endopeptidases/química , Tripsina/química , Catálise , Ativação Enzimática/efeitos dos fármacos , Hemoglobinas Glicadas/efeitos da radiação , Serina Endopeptidases/efeitos da radiação , Tripsina/efeitos da radiação
13.
Clin Chim Acta ; 358(1-2): 68-74, 2005 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-16018878

RESUMO

BACKGROUND: The trueness of glucose monitors is commonly assessed using whole-blood samples and a clinical analyzer as a comparison method. In this study, the effect of specimen matrix on trueness of one clinical analyzer and one glucose monitor was compared with a gas chromatography-mass spectrometry (GC/MS) reference method, using split-sample comparison with capillary whole blood (CWB), venous whole blood (VWB), and plasma (PL). METHODS: CWB was analyzed by the glucose monitor and the GC/MS reference method. VWB was analyzed by the glucose monitor, clinical analyzer, and the GC/MS method. PL was analyzed by the clinical analyzer and the GC/MS reference method. RESULTS: For the glucose monitor, the bias was 0.4% and -18.2% for CWB and VWB, respectively. The clinical analyzer had a bias of -25.4% for VWB and -12.0% for PL and a proportional bias was detected in both specimens. Using the clinical analyzer as a comparison method, the glucose monitor had a proportional bias of -9.8%. CONCLUSION: The trueness of clinical analyzers can be affected by the specimen matrix that needs to be assessed before they are used as comparison method to assess trueness of glucose monitors.


Assuntos
Glicemia/análise , Coleta de Amostras Sanguíneas/métodos , Cromatografia Gasosa-Espectrometria de Massas , Humanos , Valores de Referência , Análise de Regressão , Reprodutibilidade dos Testes
15.
Clin Chem ; 48(2): 220-35, 2002 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-11805003

RESUMO

BACKGROUND: Pyridinoline (PYD) and deoxypyridinoline (DPD) are two of the most extensively characterized biochemical bone markers, but the interpretation of results is hampered by biologic and other preanalytical variability. We reviewed factors contributing to preanalytical variation of pyridinium cross-links in urine. METHODS: We searched four databases for English-language reports on PYD and/or DPD in urine. Searches were restricted to humans, except for studies of stability, when the search was expanded to other species. The 599 identified articles were supplemented with references from those articles and with articles known to the authors. RESULTS: The mean reported within-day variability was 71% for PYD (range, 57-78%) and 67% for DPD (range, 53-75%). The mean interday variability was 16% for both DPD and PYD (range for PYD, 12-21%; range for DPD, 5-24%). The mean intersubject variabilities across studies were 26% for PYD (range, 12-63%) and 34% for DPD (range, 8-98%) for healthy premenopausal women and 36% (range, 22-61%) and 40%, (range, 27-54%) for postmenopausal women, respectively. Specimen instability and errors in creatinine measurements were additional sources of variability. CONCLUSIONS: Intra- and intersubject variability can be reduced by collecting specimens at a specific time of the day and by maintaining similar patient status at each specimen collection regarding factors such as medications and dietary supplements.


Assuntos
Aminoácidos/urina , Coleta de Amostras Sanguíneas , Ritmo Circadiano , Dieta , Interações Medicamentosas , Exercício Físico , Feminino , Humanos , Lactação/urina , Ciclo Menstrual , Gravidez , Estações do Ano
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA