Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Sensors (Basel) ; 22(4)2022 Feb 10.
Artigo em Inglês | MEDLINE | ID: mdl-35214262

RESUMO

Energy Expenditure (EE) (kcal/day), a key element to guide obesity treatment, is measured from CO2 production, VCO2 (mL/min), and/or O2 consumption, VO2 (mL/min). Current technologies are limited due to the requirement of wearable facial accessories. A novel system, the Smart Pad, which measures EE via VCO2 from a room's ambient CO2 concentration transients was evaluated. Resting EE (REE) and exercise VCO2 measurements were recorded using Smart Pad and a reference instrument to study measurement duration's influence on accuracy. The Smart Pad displayed 90% accuracy (±1 SD) for 14-19 min of REE measurement and for 4.8-7.0 min of exercise, using known room's air exchange rate. Additionally, the Smart Pad was validated measuring subjects with a wide range of body mass indexes (BMI = 18.8 to 31.4 kg/m2), successfully validating the system accuracy across REE's measures of ~1200 to ~3000 kcal/day. Furthermore, high correlation between subjects' VCO2 and λ for CO2 accumulation was observed (p < 0.00001, R = 0.785) in a 14.0 m3 sized room. This finding led to development of a new model for REE measurement from ambient CO2 without λ calibration using a reference instrument. The model correlated in nearly 100% agreement with reference instrument measures (y = 1.06x, R = 0.937) using an independent dataset (N = 56).


Assuntos
Dióxido de Carbono , Metabolismo Energético , Índice de Massa Corporal , Calorimetria Indireta , Humanos , Consumo de Oxigênio , Reprodutibilidade dos Testes , Descanso
2.
J Breath Res ; 15(2)2021 01 22.
Artigo em Inglês | MEDLINE | ID: mdl-33339005

RESUMO

Weight disorders are strikingly prevalent globally and can contribute to a wide array of potentially fatal diseases spanning from type II diabetes to coronary heart disease. These disorders have a common cause: poor calorie balance. Since energy expenditure (EE) (kcal d-1) constitutes one half of the calorie balance equation (the other half being food intake), its measurement could be of great value to those suffering from weight disorders. A technique for contact free assessment of EE is presented, which only relies on CO2concentration monitoring within a sealed office space, and assessment of carbon dioxide production rate (VCO2). Twenty healthy subjects were tested in a cross-sectional study to evaluate the performance of the aforementioned technique in measuring both resting EE (REE) and exercise EE using the proposed system (the 'SmartPad') and a U.S. Food and Drug Administration (FDA) cleared gold standard reference instrument for EE measurement. For VCO2and EE measurements, the method showed a correlation slope of 1.00 and 1.03 with regression coefficients of 0.99 and 0.99, respectively, and Bland-Altman plots with a mean bias = -0.232% with respect to the reference instrument. Furthermore, two subjects were also tested as part of a proof-of-concept longitudinal study where EE patterns were simultaneously tracked with body weight, sleep, stress, and step counts using a smartwatch over the course of a month, to determine correlation between the aforementioned parameters and EE. Analysis revealed moderately high correlation coefficients (Pearson'sr) for stress (raverage= 0.609) and body weight (raverage= 0.597) for the two subjects. The new SmartPad method was demonstrated to be a promising technique for EE measurement under free-living conditions.


Assuntos
Dióxido de Carbono , Diabetes Mellitus Tipo 2 , Testes Respiratórios , Calorimetria Indireta , Dióxido de Carbono/metabolismo , Estudos Transversais , Metabolismo Energético , Humanos , Estudos Longitudinais , Estados Unidos , Redução de Peso
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA