Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
2.
Joint Bone Spine ; 79(4): 379-83, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22088933

RESUMO

OBJECTIVES: Rheumatoid arthritis is characterized by an early inflammatory related periarticular osteopenia. A new high resolution direct digital X-ray device has been recently developed to provide bone texture analysis which is designed to assess changes in trabecular bone architecture. For the first time, we have evaluated trabecular bone texture impairment in rheumatoid arthritis patients compared to healthy controls. METHODS: In this cross-sectional study, the reproducibility was assessed by three separate digital X-rays of the right hand, with repositioning in 14 late rheumatoid arthritis patients and 14 healthy subjects. Then, trabecular bone texture of the MCP2 and MCP3 from patients enrolled in a prospective cohort of 78 rheumatoid arthritis patients was compared with that of 50 healthy subjects, using three texture parameters: Hmean, co-occurrence and run-length. RESULTS: The coefficients of variation of the high resolution direct digital X-ray measurements ranged from 0.5 to 1.8%. Only the Hmean parameter was significantly decreased in rheumatoid arthritis patients compared to healthy subjects at MCP2 (0.637±0.040 vs. 0.654±0.032, P<0.05) and at MCP3 (0.646±0.044 vs. 0.665±0.037, P<0.05). This reduction was significantly correlated to disease activity. CONCLUSIONS: This study demonstrated both the good reproducibility of the high resolution digital X-ray measurements and the trabecular bone texture impairment at MCP joints in rheumatoid arthritis patients. In addition to provide a high resolution hand radiograph, this technique may represent an interesting tool to easily quantify periarticular osteopenia with a low radiation dose.


Assuntos
Artrite Reumatoide/diagnóstico por imagem , Doenças Ósseas Metabólicas/diagnóstico por imagem , Ossos Metacarpais/diagnóstico por imagem , Adulto , Artrite Reumatoide/complicações , Doenças Ósseas Metabólicas/etiologia , Estudos de Casos e Controles , Estudos Transversais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X , Adulto Jovem
3.
Pediatr Nephrol ; 26(4): 587-95, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21246220

RESUMO

Bone damage in children with chronic kidney disease (CKD) is a challenge for pediatric nephrologists. Areal measurements of bone mineral density (BMD) by dual x-ray absorptiometry (DXA) have been routinely performed to assess bone mass but recent international guidelines have concluded that DXA was of less value in CKD. The aim of this study is to evaluate bone quality in CKD children using new bone imaging techniques in a pilot cross-sectional single-center study. We performed bone imaging (high-resolution peripheral quantitative computed tomography, HR-pQCT, XtremeCT, Scanco Medical AG, Switzerland), to assess compartmental volumetric BMD and trabecular microarchitecture in 22 CKD children and 19 controls. In seven younger patients (i.e., under 10 years of age), we performed bone texture analysis (BMA, D3A Medical Systems, France) in comparison to 15 healthy prepubertal controls. Among older children, CKD patients had significantly lower height and body weight without significant impairment of BMD and microarchitecture than healthy controls. In univariate analysis, there were significant correlations between cortical BMD and glomerular filtration rate (r= -0.46), age (r=0.60) and body mass index (r=0.67). In younger children, bone texture parameters were not different between patients and controls. Our results did not show significant differences between healthy controls and CKD children for compartmental bone densities and microarchitecture, but the small sample size and the heterogeneity of the CKD group require caution in the interpretation. Novel bone imaging techniques seem feasible in children, and further longitudinal studies are required to thoroughly explore long-term cardiovascular and bone consequences of phosphate-calcium metabolism deregulation during CKD.


Assuntos
Osso e Ossos/diagnóstico por imagem , Falência Renal Crônica/complicações , Adolescente , Densidade Óssea , Osso e Ossos/patologia , Criança , Estudos Transversais , Feminino , Humanos , Falência Renal Crônica/diagnóstico por imagem , Masculino , Projetos Piloto , Tomografia Computadorizada por Raios X
4.
Calcif Tissue Int ; 87(5): 385-91, 2010 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-20711834

RESUMO

Bone microarchitecture can be studied noninvasively using high-resolution peripheral quantitative computed tomography (HR-pQCT). However, this technique is not widely available, so more simple techniques may be useful. BMA is a new 2D high-resolution digital X-ray device, allowing for bone texture analysis with a fractal parameter (H(mean)). The aims of this study were (1) to evaluate the reproducibility of BMA at two novel sites (radius and tibia) in addition to the conventional site (calcaneus), (2) to compare the results obtained with BMA at all of those sites, and (3) to study the relationship between H(mean) and trabecular microarchitecture measured with an in vivo 3D device (HR-pQCT) at the distal tibia and radius. BMA measurements were performed at three sites (calcaneus, distal tibia, and radius) in 14 healthy volunteers to measure the short-term reproducibility and in a group of 77 patients with chronic kidney disease to compare BMA results to HR-pQCT results. The coefficient of variation of H(mean) was 1.2, 2.1, and 4.7% at the calcaneus, radius, and tibia, respectively. We found significant associations between trabecular volumetric bone mineral density and microarchitectural variables measured by HR-pQCT and H(mean) at the three sites (e.g., Pearson correlation between radial trabecular number and radial H(mean) r = 0.472, P < 0.001). This study demonstrated a significant but moderate relationship between 2D bone texture and 3D trabecular microarchitecture. BMA is a new reproducible technique with few technical constraints. Thus, it may represent an interesting tool for evaluating bone structure, in association with biological parameters and DXA.


Assuntos
Falência Renal Crônica/complicações , Osteoporose/diagnóstico por imagem , Rádio (Anatomia)/diagnóstico por imagem , Tíbia/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Absorciometria de Fóton/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Densidade Óssea/fisiologia , Calcâneo/diagnóstico por imagem , Calcâneo/patologia , Estudos Transversais , Feminino , Humanos , Falência Renal Crônica/diagnóstico por imagem , Falência Renal Crônica/patologia , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Osteoporose/patologia , Rádio (Anatomia)/patologia , Tíbia/patologia , Adulto Jovem
5.
Ann Rheum Dis ; 69(9): 1671-6, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20525847

RESUMO

OBJECTIVES: A new high-resolution peripheral quantitative CT (HR-pQCT) system allows for in vivo assessment of bone microarchitecture and volumetric bone mineral density (vBMD) with an 82 microm isotropic resolution. With this device, the microarchitecture impairment was evaluated in patients with rheumatoid arthritis (RA) in comparison with healthy controls and measured the erosion volume at metacarpal heads (MCPs). METHODS: In this cross-sectional study, the reproducibility was first assessed by 3 HR-pQCT exams with repositioning in 14 patients with late RA and 14 healthy subjects. Then, HR-pQCT parameters were measured in a group of 93 patients with RA and 31 healthy controls. Two RA subgroups were distinguished: early RA (disease duration < or =2 years) (n=36) and late RA (n=57) and compared them to healthy controls. RESULTS: The precision of the HR-pQCT volumetric measurements as assessed with coefficient of variation ranged from 0.7% to 1.8% in patients with late RA and from 0.6% to 1.4% in healthy subjects at MCPs. Total and trabecular vBMD and trabecular thickness were significantly decreased in patients with RA compared to healthy subjects and were significantly correlated to disease activity. The erosion volume was highly correlated to a semiquantitative assessment using the Outcome Measures in Rheumatoid Arthritis Clinical Trials (OMERACT) scoring system applied to the HR-pQCT slices. CONCLUSIONS: This study demonstrated the good reproducibility of the HR-pQCT volumetric measurements at MCPs and confirmed the involvement of trabecular compartment in periarticular osteopoenia. Thus, HR-pQCT appears interesting to simultaneously assess differences in bone volumetric density, microarchitecture and erosions.


Assuntos
Artrite Reumatoide/complicações , Doenças Ósseas Metabólicas/etiologia , Ossos Metacarpais/diagnóstico por imagem , Adulto , Artrite Reumatoide/fisiopatologia , Densidade Óssea , Doenças Ósseas Metabólicas/diagnóstico por imagem , Doenças Ósseas Metabólicas/fisiopatologia , Estudos Transversais , Progressão da Doença , Feminino , Humanos , Masculino , Ossos Metacarpais/fisiopatologia , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA