Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Heart ; 107(1): 25-32, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-32723759

RESUMO

OBJECTIVE: Mitral annular disjunction (MAD) is an abnormality linked to mitral valve prolapse (MVP), possibly associated with malignant ventricular arrhythmias. We assessed the agreement among different imaging techniques for MAD identification and measurement. METHODS: 131 patients with MVP and significant mitral regurgitation undergoing transthoracic echocardiography (TTE) and cardiac magnetic resonance (CMR) were retrospectively enrolled. Transoesophageal echocardiography (TOE) was available in 106 patients. MAD was evaluated in standard long-axis views (four-chamber, two-chamber, three-chamber) by each technique. RESULTS: Considering any-length MAD, MAD prevalence was 17.3%, 25.5%, 42.0% by TTE, TOE and CMR, respectively (p<0.05). The agreement on MAD identification was moderate between TTE and CMR (κ=0.54, 95% CI 0.49 to 0.59) and good between TOE and CMR (κ=0.79, 95% CI 0.74 to 0.84). Assuming CMR as reference and according to different cut-off values for MAD (≥2 mm, ≥4 mm, ≥6 mm), specificity (95% CI) of TTE and TOE was 99.6 (99.0 to 100.0)% and 98.7 (97.4 to 100.0)%; 99.3 (98.4 to 100.0)% and 97.6 (95.8 to 99.4)%; 97.8 (96.2 to 99.3)% and 93.2 (90.3 to 96.1)%, respectively; sensitivity (95% CI) was 43.1 (37.8 to 48.4)% and 74.5 (69.4 to 79.5)%; 54.0 (48.7 to 59.3)% and 88.9 (85.2 to 92.5)%; 88.0 (84.5 to 91.5)% and 100.0 (100.0 to 100.0)%, respectively. MAD length was 8.0 (7.0-10.0), 7.0 (5.0-8.0], 5.0 (4.0-7.0) mm, respectively by TTE, TOE and CMR. Agreement on MAD measurement was moderate between TTE and CMR (ρ=0.73) and strong between TOE and CMR (ρ=0.86). CONCLUSIONS: An integrated imaging approach could be necessary for a comprehensive assessment of patients with MVP and symptoms suggestive for arrhythmias. If echocardiography is fundamental for the anatomic and haemodynamic characterisation of the MV disease, CMR may better identify small length MAD as well as myocardial fibrosis.


Assuntos
Técnicas de Imagem Cardíaca , Insuficiência da Valva Mitral/diagnóstico por imagem , Prolapso da Valva Mitral/diagnóstico por imagem , Adulto , Idoso , Ecocardiografia , Ecocardiografia Transesofagiana , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Insuficiência da Valva Mitral/patologia , Prolapso da Valva Mitral/patologia , Imagem Multimodal , Estudos Retrospectivos
2.
J Am Soc Echocardiogr ; 32(2): 238-247, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30459122

RESUMO

BACKGROUND: Evaluation of the tricuspid annulus is crucial for the decision making at the time of left heart surgery. Current recommendations for tricuspid valve repair are based on two-dimensional (2D) transthoracic echocardiography (TTE), despite the known underestimation compared with three-dimensional (3D) echocardiography. However, little is known about the differences in 3D tricuspid annular (TA) sizing using TTE versus transesophageal echocardiography (TEE). The aims of this study were to (1) compare 2D and 3D TA measurements performed with both TTE and TEE and (2) compare two 3D methods for TA measurements: multiplanar reconstruction (MPR) and dedicated software (DS) designed to take into account TA nonplanarity. METHODS: Seventy patients underwent 2D and 3D TTE and TEE. Two-dimensional images were used to measure TA diameter from apical four-chamber, right ventricular-focused (TTE), and midesophageal four-chamber (TEE) views. Three-dimensional full-volume data sets were analyzed using both MPR and DS, to obtain major and minor axes, perimeter, and area. Intertechnique agreement was assessed using Bland-Altman analysis. RESULTS: Measurements on 2D TTE and TEE, which were view dependent, underestimated TA major dimensions in all views compared with 3D values, irrespective of the 3D method. MPR and DS measurements were significantly different, with DS resulting in larger values for all parameters, irrespective of approach. No differences were found between 3D TTE and 3D TEE for both MPR and DS. CONCLUSIONS: Our findings highlight the need for methodology that respects the 3D geometry of the tricuspid annulus, including its nonplanarity, which cannot be accurately assessed from 2D images and is not equally taken into account by different 3D measurement methodologies. Accordingly, a 3D cutoff value for TA enlargement needs to be established and is likely to be larger than the guideline-recommended 2D-based 40-mm cutoff. Importantly, noninvasive 3D TTE can be used instead of 3D TEE because TA measurements are not different.


Assuntos
Tomada de Decisões , Ecocardiografia Tridimensional/métodos , Ecocardiografia Transesofagiana/métodos , Insuficiência da Valva Tricúspide/diagnóstico , Valva Tricúspide/diagnóstico por imagem , Procedimentos Cirúrgicos Cardíacos/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes , Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA