Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
2.
Magn Reson Med ; 81(4): 2588-2599, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30536764

RESUMO

PURPOSE: To quantitatively evaluate a superresolution technique for 3D, one-millimeter isotropic diffusion-weighted imaging (DWI) of the whole breasts. METHODS: Isotropic 3D DWI datasets are obtained using a combination of (i) a readout-segmented diffusion-weighted-echo-planar imaging (DW-EPI) sequence (rs-EPI), providing high in-plane resolution, and (ii) a superresolution (SR) strategy, which consists of acquiring 3 datasets with thick slices (3 mm) and 1-mm shifts in the slice direction, and combining them into a 1 × 1 × 1-mm3 dataset using a dedicated reconstruction. Two SR reconstruction schemes were investigated, based on different regularization schemes: conventional Tikhonov or Beltrami (an edge-preserving constraint). The proposed SR strategy was compared to native 1 × 1 × 1-mm3 acquisitions (i.e. with 1-mm slice thickness) in 8 healthy subjects, in terms of signal-to-noise ratio (SNR) efficiency, using a theoretical framework, Monte Carlo simulations and region-of-interest (ROI) measurements, and image sharpness metrics. Apparent diffusion coefficient (ADC) values in normal breast tissue were also compared. RESULTS: The SR images resulted in an SNR gain above 3 compared to native 1 × 1 × 1-mm3 using the same acquisition duration (acquisition gain 3 and reconstruction gain >1). Beltrami-SR provided the best results in terms of SNR and image sharpness. The ADC values in normal breast measured from Beltrami-SR were preserved compared to low-resolution images (1.91 versus 1.97 ×10-3 mm2 /s, P = .1). CONCLUSION: A combination of rs-EPI and SR allows 3D, 1-mm isotropic breast DWI data to be obtained with better SNR than a native 1-mm isotropic acquisition. The proposed DWI protocol might be of interest for breast cancer monitoring/screening without injection.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Mama/diagnóstico por imagem , Imagem de Difusão por Ressonância Magnética , Imagem Ecoplanar/métodos , Adulto , Bases de Dados Factuais , Feminino , Voluntários Saudáveis , Humanos , Processamento de Imagem Assistida por Computador/métodos , Pessoa de Meia-Idade , Método de Monte Carlo , Razão Sinal-Ruído
3.
J Magn Reson Imaging ; 35(2): 340-51, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21990103

RESUMO

PURPOSE: To assess cardiac function by means of a novel free-breathing cardiac magnetic resonance imaging (MRI) strategy. MATERIALS AND METHODS: A stack of ungated 2D steady-state free precession (SSFP) slices was acquired during free breathing and reconstructed as cardiac cine imaging based on the generalized reconstruction by inversion of coupled systems (GRICS). A motion-compensated sliding window approach allows reconstructing cine movies with most motion artifacts cancelled. The proposed reconstruction uses prior knowledge from respiratory belts and electrocardiogram recordings and features a piecewise linear model that relates the electrocardiogram signal to cardiac displacements. The free-breathing protocol was validated in six subjects against a standard breath-held protocol. RESULTS: Image sharpness, as assessed by the image gradient entropy, was comparable to that of breath-held images and significantly better than in uncorrected images. Volumetric parameters of cardiac function in the left ventricle (LV) and right ventricle (RV) were similar, including end-systolic volumes, end-diastolic volumes and mass, stroke volumes, and ejection fractions (with differences of 3% ± 2.4 in the LV and 2.9% ± 4.4 in the RV). The duration of the free-breathing protocol was nearly the same as the breath-held protocol. CONCLUSION: Free-breathing cine-GRICS enables accurate assessment of volumetric parameters of cardiac function with efficient correction of motion.


Assuntos
Técnicas de Imagem de Sincronização Cardíaca/métodos , Ventrículos do Coração , Imagem Cinética por Ressonância Magnética/métodos , Algoritmos , Artefatos , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Modelos Lineares , Masculino , Imagens de Fantasmas , Respiração , Adulto Jovem
4.
Magn Reson Med ; 67(6): 1740-6, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22135141

RESUMO

Reproducibility of the manual assessment of right ventricle volumes by short-axis cine-MRI remains low and is often attributed to the difficulty in separating the right atrium from the ventricle. This study was designed to evaluate the regional interobserver variability of the right ventricle volume assessment to identify segmentation zones with the highest interobserver variability. Short-axis views of 90 right ventricles (30 hypertrophic, 30 dilated, and 30 normal) were acquired with 2D steady-state free precession sequences at 1.5 T and were manually segmented by two observers. The two segmentations were compared and the variations were quantified with a variation score based on the Hausdorff distance between the two segmentations and the interobserver 95% limits of concordance of the global volumes. The right ventricles were semiautomatically split into four subregions: apex, mid-ventricle, tricuspid zone, and infundibulum. These four subregions represented 11%, 34%, 36%, and 19% of the volume but, respectively, yielded variation scores of 8%, 16%, 42%, and 34%. The infundibulum yielded the highest interobserver regional variability although its variation score remained comparable to the tricuspid zone due to its lower volume. These results emphasize the importance of standardizing the segmentation of the infundibulum and the tricuspid zone to improve reproducibility.


Assuntos
Algoritmos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Imagem Cinética por Ressonância Magnética/métodos , Reconhecimento Automatizado de Padrão/métodos , Disfunção Ventricular Esquerda/patologia , Adulto , Feminino , Humanos , Aumento da Imagem/métodos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Tamanho do Órgão , Reprodutibilidade dos Testes , Sensibilidade e Especificidade