Phys Med ; 30(1): 36-46, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23510532

RESUMO

PURPOSE: We have established a high-throughput Gafchromic film dosimetry protocol for narrow kilovoltage beams in homogeneous and heterogeneous media for small-animal radiotherapy applications. The kV beam characterization is based on extensive Gafchromic film dosimetry data acquired in homogeneous and heterogeneous media. An empirical model is used for parameterization of depth and off-axis dependence of measured data. METHODS: We have modified previously published methods of film dosimetry to suit the specific tasks of the study. Unlike film protocols used in previous studies, our protocol employs simultaneous multi-channel scanning and analysis of up to nine Gafchromic films per scan. A scanner and background correction were implemented to improve accuracy of the measurements. Measurements were taken in homogeneous and inhomogeneous phantoms at 220 kVp and a field size of 5 × 5 mm(2). The results were compared against Monte Carlo simulations. RESULTS: Dose differences caused by variations in background signal were effectively removed by the corrections applied. Measurements in homogeneous phantoms were used to empirically characterize beam data in homogeneous and heterogeneous media. Film measurements in inhomogeneous phantoms and their empirical parameterization differed by about 2%-3%. The model differed from MC by about 1% (water, lung) to 7% (bone). Good agreement was found for measured and modelled off-axis ratios. CONCLUSIONS: EBT2 films are a valuable tool for characterization of narrow kV beams, though care must be taken to eliminate disturbances caused by varying background signals. The usefulness of the empirical beam model in interpretation and parameterization of film data was demonstrated.


Assuntos
Dosimetria Fotográfica/métodos , Animais , Modelos Teóricos , Método de Monte Carlo , Imagens de Fantasmas , Fatores de Tempo , Água
2.
Phys Med ; 29(5): 426-35, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23490038

RESUMO

Arc treatments require calculation of dose for collections of discrete gantry angles. The sampling of angles must balance between short computation time of small angle sets and the better calculation reliability of large sets. In this paper, an analytical formula is presented that allows calculation of dose delivered during continuous rotation of the gantry. The formula holds valid for continuous short arcs of up to about 30° and is derived by integrating a dose formula over gantry angles within a small angle approximation. Doses for longer arcs may be obtained in terms of doses for shorter arcs. The formula is derived with an empirical beam model in water and extended to inhomogeneous media. It is validated with experimental data obtained by applying arc treatment using kV small animal irradiator to a phantom of solid water and lung-equivalent material. The results are a promising step towards efficient 3D dose calculation and inverse planning purposes. In principle, this method also applies to VMAT dose calculation and optimization but requires extensions.


Assuntos
Dosimetria Fotográfica/métodos , Doses de Radiação , Planejamento da Radioterapia Assistida por Computador/métodos , Animais , Humanos , Método de Monte Carlo , Imagens de Fantasmas , Rotação , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS