Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
2.
Int J Lab Hematol ; 44(3): 619-625, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35040275

RESUMO

INTRODUCTION: There may be clinically relevant differences between results of different FIX assays in samples containing extended half life FIX concentrates requiring regular surveillance of assay results through proficiency testing exercises. Control materials used in proficiency testing must be commutable, that is have the same inter-assay properties as those demonstrated by authentic clinical samples when measured by different analytical methods. METHODS: We assessed relationships between results with different FIX assays and commutability of UK National External Quality Assessment Scheme (NEQAS) materials containing rIX-FP (Idelvion) or rFIXFc (Alprolix) by comparing results obtained using widely used one-stage and chromogenic assays during a proficiency testing exercise with results obtained when analysing a series of individual patient samples using the same assay systems. NEQAS samples prepared by addition of either Idelvion or Alprolix to FIX deficient plasma were sent to 76 haemophilia centres in Europe. A total of 18 Idelvion and 22 Alprolix patient samples were assayed in a single centre. Two chromogenic and two one-stage assays were compared. RESULTS: The pattern of results obtained for NEQAS samples and patient samples was similar. In all cases, the NEQAS sample data point was within the scatter of patient sample data in plots of patient sample results showing one-stage assay results using Synthasil or Actin FS plotted against chromogenic assay results with Biophen or Rox chromogenic FIX kits. CONCLUSION: This indicates that the NEQAS samples containing Idelvion or Alprolix were commutable and therefore suitable for use in proficiency testing exercises.


Assuntos
Fator IX , Hemofilia B , Coagulação Sanguínea , Humanos , Fragmentos Fc das Imunoglobulinas , Proteínas Recombinantes de Fusão , Albumina Sérica , Reino Unido
3.
J Thromb Haemost ; 19(9): 2263-2267, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34227230

RESUMO

BACKGROUND: Vaccine-induced immune thrombocytopenia and thrombosis (VITT) following the administration of the AstraZeneca (AZ) ChAdOx1 nCOV-19 vaccine has recently been reported. The associated clinical and laboratory features have included thrombosis at unusual sites, thrombocytopenia, and raised D-dimers with positivity for IgG anti-platelet factor 4 (PF4) antibodies. OBJECTIVES: A UK National External Quality Control Assessment Scheme external quality control exercise was carried out by distributing liquid and lyophilized samples from a subject with VITT, a pool of samples from subjects with classical heparin-induced thrombocytopenia (HIT), and a non-VITT/non-HIT case to 85 centers performing HIT testing. METHODS: Participating centers employed their locally validated testing methods for HIT assays. RESULTS: The lyophilized and liquid samples were found to be commutable for the ELISA assays used in the detection of anti-PF4 antibodies. The Aeskulisa, Stago, Hyphen, and LIFECODES anti-PF4 ELISA assays successfully detected the VITT antibody, whereas the Acustar HIT, Werfen LIA, and the Stago STIC assays did not. CONCLUSION: It is important that clinical and laboratory teams are aware of the limitations of some anti-PF4 assays when using them to aid diagnosis of VITT syndrome.


Assuntos
Púrpura Trombocitopênica Idiopática , Trombocitopenia , Trombose , Vacinas , Vacinas contra COVID-19 , ChAdOx1 nCoV-19 , Heparina/efeitos adversos , Humanos , Fator Plaquetário 4 , Púrpura Trombocitopênica Idiopática/induzido quimicamente , Púrpura Trombocitopênica Idiopática/diagnóstico , Trombocitopenia/induzido quimicamente , Trombocitopenia/diagnóstico , Reino Unido
4.
Int J Lab Hematol ; 43(5): 1198-1206, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33605545

RESUMO

INTRODUCTION: Haemolysis is considered one of the major contributors of nonconformities and sample rejection in coagulation testing. MATERIALS AND METHODS: Two lyophilized plasmas were distributed to 800 centres registered for prothrombin time (PT), activated partial thromboplastin time (APTT) and either Clauss fibrinogen or thrombin time (TT) in the UK NEQAS BC programme. The same pool of normal plasma was used to prepare both samples, to one of which red blood cell haemolysate was added to mimic haemolysis at 3 g/L haemoglobin concentration. Participants were asked to complete a questionnaire about their laboratory approach to dealing with haemolysed samples, including strategies used to deal with different levels of haemolysis. RESULTS: Results for tests performed did not show great differences between the two samples. It should be noted that artificially constructed haemolysed samples may not behave in the same way as patient samples (ie, may not be commutable). However, the possibility of carrying out a large multicentre study for detection of haemolysis was demonstrated. Inconsistency in practice was observed with 226/551 (41%) of centres indicated they reject haemolysed samples solely on visual checks, and 163 (30%) using initial visual checks with further sample rejection evaluation by analyser flags. Furthermore, 333 (72%) of centres indicated that the level of haemolysis affects sample rejection decisions, while 132 (28%) stated it did not. CONCLUSION: Variability of responses for dealing with haemolysed samples reflects a lack of clear consistency in the pre-analytical area of sample processing.


Assuntos
Testes de Coagulação Sanguínea/métodos , Coagulação Sanguínea , Fibrinogênio/análise , Hemólise , Hemostasia , Humanos , Reino Unido
5.
J Clin Pathol ; 65(12): 1119-23, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23038688

RESUMO

BACKGROUND: Vitamin K antagonists have been used for many decades and have been traditionally monitored by the measurement of the International Normalised Ratio (INR) in the laboratory. Introduction of Point of Care (POC) testing devices to measure INR has resulted in many tests being undertaken in primary care. External Quality Assessment (EQA) of these POC devices is recommended to ensure accuracy and reliability of INR results outside a laboratory setting. AIM: To assess the quality of INR results for users of two POC devices (CoaguChek XS and CoaguChek XS Plus) over a four-year period. METHODS: Four surveys (two samples) were sent in each 12-month period. The median INR value of each sample was calculated and the percentage deviation from this median determined. Any results greater than 15% from the median were considered to be outside consensus which indicated a possible problem within the testing system. RESULTS: Variability of INR results in this UK National External Quality Assessment Scheme (NEQAS) programme was comparable to that in the UK NEQAS EQA programme for laboratory INR testing. Occurrence of persistent problems was lower in the POC programme than the laboratory programme. CONCLUSIONS: Utilisation of an EQA programme for POC devices in primary care is feasible and necessary. Our data suggest for those health professionals using EQA, the reliability and accuracy of INR testing matches the quality of laboratory testing.


Assuntos
Coagulação Sanguínea/fisiologia , Coeficiente Internacional Normatizado/instrumentação , Sistemas Automatizados de Assistência Junto ao Leito/normas , Garantia da Qualidade dos Cuidados de Saúde , Humanos , Coeficiente Internacional Normatizado/normas , Reino Unido
7.
Semin Thromb Hemost ; 35(8): 778-85, 2009 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-20169514

RESUMO

We report the results of external quality assessment exercises in which 60 to 120 centers performed factor VIII (FVIII) inhibitor testing on a series of samples over a 13-year period. Samples from seven different subjects were distributed for analysis comprising the following: four different subjects with severe hemophilia A with antibodies following replacement therapy, one subject with acquired hemophilia A and antibodies to FVIII, one subject with normal FVIII and an easily detected lupus anticoagulant, and one subject with mild hemophilia A and a difficult-to-detect lupus anticoagulant but without antibodies to FVIII. In all of the surveys the results obtained in different centers analyzing the same sample varied to an extent that would influence patient management decisions. In the UK National External Quality Assessment Scheme surveys reported here, there was considerable interlaboratory variation in the results of FVIII inhibitor testing that did not improve over the survey period. The coefficient of variation of results in different centers was between 33% and 106% in samples from patients with severe congenital hemophilia A. In some cases, results were affected by assay components. For one plasma, the mean FVIII inhibitor results in centers using one source of normal plasma was 3.9 Bethesda unit (BU)/mL compared with a mean of 5.7 BU/mL in centers using a different normal plasma source ( P = 0.04). Our data indicate that the detection of FVIII inhibitors is not the same in different centers, and the degree of variability noted makes it likely that assay variability has contributed to the lack of international consensus in relation to the real incidence of FVIII inhibitors in different clinical settings. Improvements in assay standardization are urgently needed.


Assuntos
Testes de Coagulação Sanguínea/normas , Hemofilia A/sangue , Animais , Autoanticorpos/sangue , Fatores de Coagulação Sanguínea/uso terapêutico , Fator VIII/imunologia , Hemofilia A/tratamento farmacológico , Humanos , Garantia da Qualidade dos Cuidados de Saúde , Sensibilidade e Especificidade , Reino Unido
8.
Semin Thromb Hemost ; 33(3): 243-9, 2007 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-17427058

RESUMO

The pattern of tests employed and technologies developed within hemostasis laboratories has changed considerably within the last 10 years. These changes have presented challenges to external quality assessment (EQA) providers, including the United Kingdom National External Quality Assessment Scheme (NEQAS). EQA for point-of-care devices used for monitoring oral anticoagulant therapy has focused on provision of suitable material to assess performance of devices designed for capillary blood testing, and on education of a user group not usually trained in laboratory quality control procedures. Development of novel therapeutic agents for hemophilia has presented challenges regarding standardization of assays for monitoring treatment, whereas advances related to laboratory testing and automation have not always been accompanied by improved accuracy and precision. EQA provision has also been shown to be of value in molecular genetic screening tests for thrombophilia, and in highlighting standardization issues related to D-dimer measurement in the exclusion of deep vein thrombosis. The increasing prevalence of screening tests of global hemostasis, such as thrombin generation tests and thromboelastography, presents additional challenges to EQA providers in the attempt to standardize these new and potentially beneficial technologies.


Assuntos
Anticoagulantes/administração & dosagem , Química Clínica/métodos , Química Clínica/normas , Administração Oral , Anticoagulantes/uso terapêutico , Calibragem , Monitoramento de Medicamentos , Fator VIII/biossíntese , Produtos de Degradação da Fibrina e do Fibrinogênio/biossíntese , Testes Hematológicos/métodos , Hemostasia , Humanos , Coeficiente Internacional Normatizado , Controle de Qualidade , Tromboelastografia/métodos , Reino Unido , Trombose Venosa/diagnóstico
9.
Semin Thromb Hemost ; 32(5): 492-8, 2006 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-16862522

RESUMO

In recognition of the importance of von Willebrand factor (vWF) testing in the diagnosis of von Willebrand disease (vWD), the United Kingdom National External Quality Assessment Scheme for Blood Coagulation regularly distributes samples for determination of vWF:antigen (vWF:Ag). Data from 10 separate surveys performed between 2001 and 2005 are reviewed. These include results from ~200 different centers, of which 55% are within the United Kingdom and the remainder are from other countries. During the period of the surveys, the use of immunoelectrophoresis for determination of vWF:Ag practically disappeared and was largely replaced by latex agglutination assays. The coefficient of variation (CV) of results in different centers was approximately 15 to 20% for most vWF:Ag techniques, with CVs of approximately 7% for a fluorescence-based assay. Several different techniques were used for determination of vWF ristocetin cofactor activity (vWF:RCo), all of which were associated with poor agreement among centers as indicated by CVs of 40 to 50%. Several centers calculated the ratio of vWF:Ag/vWF:RCo but with variable success. Ratios compatible with either type 1 or type 2 vWD were obtained on samples from subjects with type 1 vWD, as well as on samples from subjects with genetically confirmed type 2 vWD. Overall, our data show that laboratory testing for vWD remains problematic. It remains to be seen whether newer techniques will offer consistently improved precision.


Assuntos
Transtornos da Coagulação Sanguínea/diagnóstico , Técnicas de Laboratório Clínico/normas , Laboratórios/normas , Fator de von Willebrand/análise , Coagulação Sanguínea , Humanos , Controle de Qualidade , Reprodutibilidade dos Testes , Reino Unido
10.
Thromb Haemost ; 94(1): 17-25, 2005 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-16113779

RESUMO

Combined oral contraceptives, oral hormone replacement therapy and thrombophilias are recognised risk factors for venous thromboembolism in women. The objective of this study was to assess the risk of thromboembolism among women with thrombophilia who are taking oral contraceptives or hormone replacement therapy, conducting a systematic review and metaanalysis. Of 201 studies identified, only nine met the inclusion criteria. Seven studies included pre-menopausal women on oral contraceptives and two studies included peri-menopausal women on hormone replacement therapy. For oral contraceptive use, significant associations of the risk of venous thromboembolism were found in women with factor V Leiden (OR 15.62; 95%CI 8.66 to 28.15); deficiencies of antithrombin (OR 12.60; 95%CI 1.37 to 115.79), protein C (OR 6.33; 95%CI 1.68 to 23.87), or protein S (OR 4.88; 95%CI 1.39 to 17.10), elevated levels of factor VIIIc (OR 8.80; 95%CI 4.13 to 18.75); and factor V Leiden and prothrombin G20210A (OR 7.85; 95%CI 1.65 to 37.41). For hormone replacement therapy, a significant association was found in women with factor V Leiden (OR 13.16; 95%CI 4.28 to 40.47). Although limited by the small number of studies, the findings of this study support the presence of interaction between thrombophilia and venous thromboembolism among women taking oral contraceptives. However, further studies are required to establish with greater confidence the associations of these, and other, thrombophilias with venous thromboembolism among hormone users.


Assuntos
Anticoncepcionais Orais/efeitos adversos , Anticoncepcionais Orais/farmacologia , Terapia de Reposição Hormonal , Programas de Rastreamento/economia , Programas de Rastreamento/métodos , Trombofilia/genética , Trombofilia/patologia , Trombose/diagnóstico , Trombose/genética , Trombose Venosa/diagnóstico , Adulto , Estudos de Casos e Controles , Estudos de Coortes , Bases de Dados como Assunto , Fator V , Feminino , Terapia de Reposição Hormonal/efeitos adversos , Humanos , Pessoa de Meia-Idade , Razão de Chances , Perimenopausa , Pré-Menopausa , Protrombina/genética , Risco , Tromboembolia/prevenção & controle , Trombofilia/complicações , Trombose Venosa/induzido quimicamente
11.
Lancet ; 359(9321): 1919-20, 2002 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-12057557

RESUMO

The factor V Leiden (FVL) mutation is associated with vascular complications in pregnancy, and routine screening of all pregnant women has been suggested. We did a prospective, unselected study in 967 pregnant women to evaluate the cost-effectiveness of screening all women, or only those with a personal or family history of venous thrombosis (n=113). When anticoagulant prophylaxis was assumed to effect a 50% reduction in vascular complications, we recorded an additional management cost of 3768 pounds sterling with selective screening and 39,841 pounds sterling with universal screening. This additional cost would result in prevention of less than one and three vascular events,respectively. Our findings, therefore, suggest that screening of pregnant women for the FVL mutation is not cost-effective.


Assuntos
Análise Custo-Benefício , Fator V/genética , Programas de Rastreamento/economia , Programas Nacionais de Saúde/economia , Complicações na Gravidez/diagnóstico , Trombose Venosa/diagnóstico , Feminino , Humanos , Programas de Rastreamento/métodos , Gravidez , Complicações na Gravidez/prevenção & controle , Estudos Prospectivos , Reino Unido , Trombose Venosa/prevenção & controle
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA