Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Korean Circ J ; 2024 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-38956940

RESUMO

BACKGROUND AND OBJECTIVES: Angiographic assessment of coronary stenosis severity using quantitative coronary angiography (QCA) is often inconsistent with that based on fractional flow reserve (FFR) or intravascular ultrasound (IVUS). We investigated the incidence of discrepancies between QCA and FFR or IVUS, and the outcomes of FFR- and IVUS-guided strategies in discordant coronary lesions. METHODS: This study was a post-hoc analysis of the FLAVOUR study. We used a QCA-derived diameter stenosis (DS) of 60% or greater, the highest tertile, to classify coronary lesions as concordant or discordant with FFR or IVUS criteria for percutaneous coronary intervention (PCI). The patient-oriented composite outcome (POCO) was defined as a composite of death, myocardial infarction, or revascularization at 24 months. RESULTS: The discordance rate between QCA and FFR or IVUS was 30.2% (n=551). The QCA-FFR discordance rate was numerically lower than the QCA-IVUS discordance rate (28.2% vs. 32.4%, p=0.050). In 200 patients with ≥60% DS, PCI was deferred according to negative FFR (n=141) and negative IVUS (n=59) (15.3% vs. 6.5%, p<0.001). The POCO incidence was comparable between the FFR- and IVUS-guided deferral strategies (5.9% vs. 3.4%, p=0.479). Conversely, 351 patients with DS <60% underwent PCI according to positive FFR (n=118) and positive IVUS (n=233) (12.8% vs. 25.9%, p<0.001). FFR- and IVUS-guided PCI did not differ in the incidence of POCO (9.5% vs. 6.5%, p=0.294). CONCLUSIONS: The proportion of QCA-FFR or IVUS discordance was approximately one third for intermediate coronary lesions. FFR- or IVUS-guided strategies for these lesions were comparable with respect to POCO at 24 months. TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT02673424.

2.
Environ Res ; 241: 117678, 2024 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-37984788

RESUMO

BACKGROUND: Ambient PM2.5 pollution (APMP2.5) was the leading environmental risk factor for cardiovascular diseases (CVDs) worldwide. An up-to-date comprehensive study is needed to provide global epidemiological patterns. METHODS: Detailed data on CVDs burden attributable to APMP2.5 were obtained from the Global Burden of Disease Study (GBD) 2019. We calculated the estimated annual percentage change (EAPC) to assess temporal trends in age-standardized rates of deaths and disability-adjusted life years (DALYs) over 30 years. RESULTS: Globally, CVDs attributable to APMP2.5 resulted in 2.48 million deaths and 60.91 million DALYs, with an increase of 122%, respectively from 1990 to 2019. In general, men suffered markedly higher burden than women, but the gap will likely turn narrow. As for age distribution, CVDs deaths and DALYs attributable to APMP2.5 mainly occurred in the elder group (>70 years). Low- and middle-income regions endured the higher CVDs burden due to the higher exposure to APMP2.5, and the gap may potentially expand further compared with high-income regions. For regions, the highest age-standardized rates of APMP2.5-related CVDs deaths and DALYs were observed mainly in Central Asia, while the lowest was observed in Australasia. At the national level, countries with the largest ASDR decline were clustered in western Europe, while Equatorial Guinea, Timor-Leste and Bhutan exhibited relatively rapid increases over this period. CONCLUSIONS: The global CVDs burden attributable to APMP2.5 has contributed to the heterogeneity of spatial and temporal distribution. APMP2.5-related CVDs deaths have largely shifted from higher SDI regions to those with a lower SDI. Globally, APMP2.5-attributable CVDs pose a significant threat to public health and diseases burden has increased over time, particularly in male, old-aged populations. The governments and health systems should take measures to reduce air pollution to impede this rising trend.


Assuntos
Poluição do Ar , Doenças Cardiovasculares , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Doenças Cardiovasculares/induzido quimicamente , Doenças Cardiovasculares/epidemiologia , Carga Global da Doença , Anos de Vida Ajustados por Qualidade de Vida , Poluição do Ar/efeitos adversos , Saúde Global , Material Particulado/toxicidade
3.
JACC Asia ; 3(5): 689-706, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38095005

RESUMO

Coronary physiologic assessment is performed to measure coronary pressure, flow, and resistance or their surrogates to enable the selection of appropriate management strategy and its optimization for patients with coronary artery disease. The value of physiologic assessment is supported by a large body of evidence that has led to major recommendations in clinical practice guidelines. This expert consensus document aims to convey practical and balanced recommendations and future perspectives for coronary physiologic assessment for physicians and patients in the Asia-Pacific region based on updated information in the field that including both wire- and image-based physiologic assessment. This is Part 1 of the whole consensus document, which describes the general concept of coronary physiology, as well as practical information on the clinical application of physiologic indices and novel image-based physiologic assessment.

4.
JACC Asia ; 3(6): 825-842, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38155788

RESUMO

Coronary physiologic assessment is performed to measure coronary pressure, flow, and resistance or their surrogates to enable the selection of appropriate management strategy and its optimization for patients with coronary artery disease. The value of physiologic assessment is supported by a large body of clinical data that has led to major recommendations in all practice guidelines. This expert consensus document aims to convey practical and balanced recommendations and future perspectives for coronary physiologic assessment for physicians and patients in the Asia-Pacific region, based on updated information in the field that includes both wire- and image-based physiologic assessment. This is Part 2 of the whole consensus document, which provides theoretical and practical information on physiologic indexes for specific clinical conditions and patient statuses.

5.
Quant Imaging Med Surg ; 12(2): 949-958, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35111596

RESUMO

BACKGROUND: Non-invasive fractional flow reserve (FFR) has been increasingly used in the clinical workflow to assist clinical decision-making for percutaneous coronary intervention (PCI). This clinical study evaluates the diagnostic accuracy of coronary stenosis assessed by a non-invasive FFR analysis method (termed AccuFFRangio) based on invasive coronary angiography (ICA). It is a blinded, self-controlled, retrospective, and dual-center clinical investigation study. METHODS: Coronary angiography data and the related information of 320 patients with 320 vessels were collected, and AccuFFRangio was used to assess the FFR for these patients. Compared with the wire-measured FFR values, we evaluated AccuFFRangio performance by its accuracy, sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV). RESULTS: The diagnostic accuracy, sensitivity, specificity, PPV, and NPV for AccuFFRangio in identifying hemodynamically significant coronary stenosis were 93.3%, 92.6%, 93.5%, 84.3%, and 97.1%, respectively. The direct correlation between computed AccuFFRangio and measured FFR was 0.812 (P<0.001), and the area under the receiver operating characteristic curve (AUC) value of AccuFFRangio was 0.96. CONCLUSIONS: This clinical study demonstrates the efficiency and accuracy of AccuFFRangio for clinical implementation when using invasive wire-measured FFR as a reference. Further validation is required in a large prospective multicenter study.

6.
Quant Imaging Med Surg ; 11(11): 4543-4555, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34737922

RESUMO

BACKGROUND: Intravascular ultrasound (IVUS) provides good insight into lumen boundary and plaques; however, it is still difficult to detect functionally significant stenosis from IVUS images for the guidance of coronary percutaneous intervention (PCI). This study aimed to develop a novel method to estimate fractional flow reserve (FFR) value for determining the functional significance of coronary artery disease through the fusion of IVUS and X-ray angiographic images. METHODS: We developed a novel approach to 3D vessel reconstruction by integrating IVUS with X-ray angiographic images. Based on the reconstructed geometry and the inlet flow derived from the thrombolysis in myocardial infarction (TIMI) frame count, a simplified fluid dynamics equation was established to compute the pressure drop and IVUS-derived FFR (AccuFFRivus) was subsequently obtained. To validate the feasibility and performance of this IVUS-based FFR method, we performed AccuFFRivus calculations on 32 coronary vessels with invasive FFR as the reference standard. RESULTS: Great correlation (r=0.86, P<0.001) was observed between AccuFFRivus and FFR. The area under the receiver-operating characteristic curve (AUC) was higher for AccuFFRivus than minimal lumen area (MLA, <4 mm2) and diameter stenosis rate (DS% ≥50%) [0.98 (95% CI: 0.86 to 1.0) vs. 0.78 (95% CI: 0.60 to 0.91) and 0.66 (95% CI: 0.47 to 0.82)]. Bland-Altman plot showed a mean difference value of -0.011 (limits of agreement: -0.156 to 0.134). CONCLUSIONS: AccuFFRivus is a novel method for hybridizing IVUS and X-ray angiographic images to identify functionally significant stenosis with FFR ≤0.80. The good diagnostic performance from the initial validation study demonstrates the potential for clinical utilization of physiologically guided decision-making. Further validation is required in future studies with a large number of cases.

7.
J Comp Eff Res ; 10(8): 697-708, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33856233

RESUMO

Background: Surgical aortic valve replacement (SAVR) has long been the standard treatment for patients with severe aortic stenosis in China, but the costs of SAVR from a hospital perspective in China have not been thoroughly researched. Currently, diagnosis-related groups in China are based on historical expenses that are closely related to the unit charges set by the official pricing department and are frequently inaccurate compared with actual resource consumption. Materials & methods: Through a retrospective empirical study on the costs and charges of SAVR cases in a tertiary hospital, this study aimed to compare the costs and charges of service items. We collected clinical information from patients undergoing SAVR (isolated or concomitant procedures) and financial information from the hospital in 2015 and 2016. Top-down full cost accounting and step-allocation were the main methods used in this study. Result: This research selected 203 SAVR cases in 2015 and 214 cases in 2016. The median length of hospital stay was 15.92 days (6.07 days pre surgery and 9.57 days post surgery). The average human resource cost of care per day per bed in the cardiovascular surgery department, including doctors and nurses, was US $62.22 in 2015 and $66.17 in 2016, but the corresponding charge was no more than $24. For operation, the cost of isolated SAVR was $665 in 2015 and $1015 in 2016, while the charge was $820. For anesthesiology, the cost of isolated SAVR was $400 in 2015 and $526 in 2016, while the average charge was $192. For examination service items, some costs did not exceed charges. The average total cost of a case was $19,299 ± 8954, while the average total charge was $18,923 ± 9194. Conclusion: SAVR is associated with significant resource utilization and hospital stay duration. The fees for human resources and services associated with SAVR do not reflect the true costs of SAVR in a Chinese hospital setting. This study may assist in future budget planning and price setting for policy makers in China.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , China , Grupos Diagnósticos Relacionados , Humanos , Estudos Retrospectivos , Fatores de Risco , Centros de Atenção Terciária , Resultado do Tratamento
8.
Catheter Cardiovasc Interv ; 91(5): 986-994, 2018 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-29399947

RESUMO

OBJECTIVES: To explore assessment of supra-annular structure for self-expanding transcatheter heart valve (THV) size selection in patients with bicuspid aortic stenosis (AS). BACKGROUND: Annulus-based device selection from CT measurement is the standard sizing strategy for tricuspid aortic valve before transcatheter aortic valve replacement (TAVR). Because of supra-annular deformity, device selection for bicuspid AS has not been systemically studied. METHODS: Twelve patients with bicuspid AS who underwent TAVR with self-expanding THVs were included in this study. To assess supra-annular structure, sequential balloon aortic valvuloplasty was performed in every 2 mm increments until waist sign occurred with less than mild regurgitation. Procedural results and 30 day follow-up outcomes were analyzed. RESULTS: Seven patients (58.3%) with 18 mm; three patients (25%) with sequential 18 mm, 20 mm; and only two patients (16.7%) with sequential 18 mm, 20 mm, and 22 mm balloon sizing were performed, respectively. According to the results of supra-annular assessment, a smaller device size (91.7%) was selected in all but one patient compared with annulus based sizing strategy, and the outcomes were satisfactory with 100% procedural success. No mortality and 1 minor stroke were observed at 30 d follow-up. The percentage of NYHA III/IV decreased from 83.3% (9/12) to 16.7% (2/12). No new permanent pacemaker implantation and no moderate or severe paravalvular leakage were found. CONCLUSIONS: A supra-annular structure based sizing strategy is feasible for TAVR in patients with bicuspid AS.


Assuntos
Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/anormalidades , Doenças das Valvas Cardíacas/diagnóstico por imagem , Doenças das Valvas Cardíacas/cirurgia , Próteses Valvulares Cardíacas , Tomografia Computadorizada por Raios X , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/fisiopatologia , Valvuloplastia com Balão , Doença da Válvula Aórtica Bicúspide , Tomada de Decisão Clínica , Ecocardiografia , Estudos de Viabilidade , Feminino , Doenças das Valvas Cardíacas/fisiopatologia , Humanos , Masculino , Complicações Pós-Operatórias/etiologia , Valor Preditivo dos Testes , Desenho de Prótese , Recuperação de Função Fisiológica , Estudos Retrospectivos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
10.
Chin Med J (Engl) ; 128(15): 2000-5, 2015 Aug 05.
Artigo em Inglês | MEDLINE | ID: mdl-26228209

RESUMO

BACKGROUND: Fractional flow reserve (FFR) is currently considered as the gold standard for evaluating the functional significance of coronary stenosis. However, its potential benefits in real-world practice remain unknown in China. This study aimed to test the hypothesis that the use of FFR is associated with improved outcome and reduced cost in Chinese real-world clinical practice. METHODS: A retrospective cohort study was carried out using the database of Second Affiliated Hospital of Zhejiang University, a tertiary and high-volume center in China. Clinical events were compared using the Cox proportional hazards model during a median follow-up of 13 months. RESULTS: The study cohort consisted of 366 consecutive patients referred for coronary revascularization with adjunct FFR and 366 matched controls, from 2010 to 2014. Major adverse cardiac events (MACEs) (death, myocardial infarction, repeated revascularization, or hospitalization for angina) at 4 years were found in 12.0% of angiography-guided patients and 4.9% in the FFR-guided group (P < 0.001). The mean number of implanted stents was significantly lower in FFR treated subjects (0.52 ± 0.82 stents) compared with the angiography-guided group (0.93 ± 0.96 stents) (P < 0.001). No difference in overall costs at initial hospitalization was observed between angiography-guided percutaneous coronary intervention (PCI) compared with FFR-guided PCI (RMB 33,000 Yuan, range: RMB 7393-44,700 Yuan) versus RMB 21,200 Yuan (RMB 19,100-47,100 Yuan) (P = 0.54). However, costs for MACEs during follow-up were significantly reduced in the FFR-guided arm (P < 0.001). CONCLUSIONS: In the contemporary clinical practice, FFR-guided PCI is associated with decreased use of stents, improved clinical outcome, and reduced costs, compared with angiography-guided PCI.


Assuntos
Reserva Fracionada de Fluxo Miocárdico/fisiologia , Intervenção Coronária Percutânea/economia , Intervenção Coronária Percutânea/métodos , Idoso , China , Custos e Análise de Custo , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
11.
Zhonghua Xin Xue Guan Bing Za Zhi ; 42(10): 835-9, 2014 Oct.
Artigo em Chinês | MEDLINE | ID: mdl-25547447

RESUMO

OBJECTIVE: To evaluate the value of preoperative assessment on transcatheter aortic valve implantation (TAVI) procedure with high-pitch dual-source computed tomography angiography (CTA). METHODS: Seventeen consecutive patients with severe symptomatic aortic stenosis underwent TAVI in our department from December 2012 to December 2013 were examined by 128-slice prospective ECG-triggered high-pitch spiral CTA and the clinical data were analyzed. Aortic annulus, sinus of Valsalva, sinotubular junction, ascending aorta and native leaflet to coronary ostium length were measured. Peripheral vascular access was evaluated. Then the patients were assessed on the suitability for TAVI procedure and prosthetic valve sizes. RESULTS: Mean diameter of the aortic annulus was (25.7 ± 2.0) mm, perimeter mean diameter was (26.4 ± 2.0) mm, area mean diameter was (25.4 ± 1.9) mm. Mean diameter of sinus of Valsalva was (34.0 ± 3.8) mm. Mean diameter of sinotubular junction was (30.5 ± 3.2) mm. Mean diameter of ascending aorta was (37.8 ± 2.8) mm. The length from native leaflet to left coronary ostium was (14.0 ± 2.0) mm, and the length from native leaflet to right coronary ostium was (15.9 ± 3.6) mm. Mean diameter of left iliac arteries was (7.5 ± 1.4) mm. Mean diameter of right iliac arteries was (7.4 ± 1.2) mm. Mean diameter of left femoral arteries was (7.4 ± 1.2) mm. Mean diameter of right femoral arteries was (7.3 ± 1.3) mm. One patient was considered ineligible for TAVI because of large aortic annulus diameter. Three patients died prior to TAVI. Two patients refused to undergo TAVI. Eleven patients underwent TAVI, 26# prosthetic valve was implanted in 1 patient, 29# prosthetic valve implanted in 6 patients, 31# prosthetic valve implanted in 4 patients. Prosthetic valve implantation was successful in 9 patients and only mild or trace perivalvular leakage was observed in these patients. Moderate perivalvular leakage were observed in 2 patients because of the location of implantation was too low, and perivalvular leakage was significantly reduced after re-implantation with same size prosthetic valve at a higher location. CONCLUSIONS: CTA can be used to evaluate the aortic root anatomy and vascular access, and help to choose the right size of prosthetic valve. CTA has an important practical value in preoperative screening of TAVI procedure.


Assuntos
Angiografia , Implante de Prótese de Valva Cardíaca , Aorta Torácica , Valva Aórtica , Estenose da Valva Aórtica , Cateterismo Cardíaco , Vasos Coronários , Artéria Femoral , Humanos , Estudos Prospectivos , Índice de Gravidade de Doença , Seio Aórtico , Tomografia , Substituição da Valva Aórtica Transcateter
13.
J Zhejiang Univ Sci B ; 14(8): 659-63, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23897783

RESUMO

Outcomes research, which investigates the outcomes of health care practices, is intended to provide scientific evidence for clinical decision making and health care. This paper elucidates the goal and domains of outcomes research. Also it shows the potential and promise of outcomes research to provide a methodology to uncover what to do and how to do it, and enable the health care profession to achieve the right care, for the right patient, at the right time, the first time, every time, nothing more, and nothing less.


Assuntos
Avaliação de Resultados em Cuidados de Saúde/métodos , Atenção à Saúde , Custos de Cuidados de Saúde , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/diagnóstico , Infarto do Miocárdio/terapia , Qualidade da Assistência à Saúde , Estados Unidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA