Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Int J Cardiovasc Imaging ; 39(12): 2465-2474, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37728801

RESUMO

Speckle tracking echocardiography (STE) derived longitudinal strain (LS) and noninvasive pressure-strain loop (PSL) derived myocardial work (MW) are more sensitive than conventional echocardiographic parameters in quantitative assessment of early myocardial dysfunction. The aim of this study was to assess left ventricular (LV) global and regional myocardial function in symptomatic chronic coronary syndrome (CCS) patients using the two promising methods. Transthoracic echocardiography was performed on patients with angina or equivalent symptoms before coronary angiography. STE-based LS and PSL-based MW analysis were carried out on each patient for global and regional myocardial function assessment. A total of 102 patients were classified into significant and nonsignificant coronary artery stenosis (CAS) groups. Among global myocardial function parameters, LS had the biggest area under the curve (AUC) of 0.735, with cutoff value of 18.4% (sensitivity, 79.6%; specificity, 72.9%), but remained statistically alike with all MW indices in predicting significant CAS (P>0.05 for all). Among regional myocardial function parameters, both LS and MW indices had predictive value for significant left anterior descending artery (LAD) or left circumflex artery (LCX) stenosis, while only myocardial work efficiency (MWE) for right coronary artery (RCA) stenosis. Both global and regional LS and MW have predictive value for significant CAS, but their value of regionalized assessment varies with specific coronary artery involvement.


Assuntos
Estenose Coronária , Ecocardiografia , Humanos , Constrição Patológica , Valor Preditivo dos Testes , Ecocardiografia/métodos , Estenose Coronária/diagnóstico por imagem , Angiografia Coronária , Síndrome , Função Ventricular Esquerda
2.
Ann Transl Med ; 9(16): 1309, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34532446

RESUMO

BACKGROUND: The assessment of interatrial septum (IAS) requires a standardized, systematic approach, including two-dimensional transthoracic echocardiography (2D TTE), 2D transesophageal echocardiography (2D TEE), and three-dimensional (3D) TEE. Although 2D TEE has been widely used for the preoperative assessment of atrial septal defect (ASD), its ability to provide reliable information is often limited due to the structural characteristics of IAS. The introduction of 3D TEE provides a unique "en face" view of IAS, which allows the visualization and accurate measurements of diameters, area, and rims of ASD. Hence, appropriate ASD imaging information is particularly important in successful transcatheter closure. METHODS: In this retrospective study, 2D TTE/TEE, and 3D TEE were performed before ASD closure, with 2D minimal and maximal diameters, areas, and residual rims being recorded. Adequate 3D TEE imaging data sets were collected and then analyzed. ASD related parameters were compared using different echocardiography. Patients who underwent ASD closure completed a clinical follow-up. RESULTS: The mean defect maximal diameter and aperture area by 3D TEE was significantly larger than that of the corresponding 2D TEE (P<0.05). There was no statistical difference in the minimal and maximal diameter or area by TEE for circular-shaped ASDs. For oval ASDs, mean minimal diameter on 2D TEE was larger than that on 3D TEE. The mean maximal diameter measured using 2D TEE was smaller than the 3D TEE measurement (16.0±7.1 vs. 19.8±8.6; P<0.05). For complex-shaped defects, there were statistical differences in minimal and maximal diameter between TEEs. Furthermore, 2D and 3D TEE had a longer superior vena cava (SVC) residual rim than did 2D TTE (P<0.05). The 3D TEE residual rims of the inferior vena cava (IVC) was significantly larger than the corresponding 2D TEE. There was a very strong correlation between the residual rim measurements using 3D and 2D TEE. However, the limits of agreement between 2D and real-time 3D TEE measurements were more apparent in the IVC rim group than in the other groups. CONCLUSIONS: Our study confirms the value of 3D TEE in assessing ASD shape and size reported by previous studies, and is also the first to accurately and systematically characterize ASD residual rim in complex ASDs.

3.
Atherosclerosis ; 299: 45-52, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-32240838

RESUMO

BACKGROUND AND AIMS: Fatty liver diseases are highly prevalent in patients with coronary artery disease (CAD) and might progress to irreversible liver fibrosis. Whether baseline liver fibrosis (LF) scores are associated with long-term mortality among patients with CAD requires investigation. METHODS: The analysis was conducted based on a prospective cohort study among 3263 patients with CAD in China. Cox models were used to assess the association of baseline levels of LF scores, including non-alcoholic fatty liver disease fibrosis score (NFS), fibrosis 4 score (FIB-4), aspartate aminotransferase to platelet ratio index (APRI), gamma-glutamyltransferase to platelet ratio (GPR), and Forns score, with the risk of all-cause and cardiovascular mortality among CAD patients. RESULTS: During a median follow-up period of 7.56 (inter-quartile range: 6.86-8.31) years, 538 deaths were identified, 319 of those were due to cardiovascular diseases. Compared with patients with lowest score levels, multivariable-adjusted HRs (95% CI) for those with highest levels of NFS, FIB-4, APRI, GPR and Forns score were 2.89 (2.14-3.91), 2.84 (2.14-3.76), 1.77 (1.33-2.36), 1.47 (1.19-1.83) and 3.10 (1.88-5.11) for all-cause mortality, 3.02 (2.05-4.45), 3.34 (2.29-4.86), 1.99 (1.40-2.83), 1.80 (1.36-2.39) and 2.43 (1.28-4.61) for cardiovascular mortality, respectively. These associations were consistent when we excluded those who died within the first year of follow-up or stratified patients by different sex, age, BMI, diabetes status, metabolic syndrome status, CAD type and hsCRP level. CONCLUSIONS: Higher LF scores are associated with increased risks of all-cause and cardiovascular mortality among CAD patients. LF scores might play a potential role in CAD prognosis prediction.


Assuntos
Doença da Artéria Coronariana/mortalidade , Indicadores Básicos de Saúde , Cirrose Hepática/diagnóstico , Idoso , Causas de Morte , China , Doença da Artéria Coronariana/diagnóstico por imagem , Feminino , Humanos , Cirrose Hepática/mortalidade , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prognóstico , Estudos Prospectivos , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo
4.
Eur Radiol ; 29(2): 963-974, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30019144

RESUMO

OBJECTIVES: Cardiac lead perforation is a rare but potentially life-threatening event. The purpose of this study was to investigate the diagnostic performances of chest radiography, transthoracic echocardiography (TTE) and electrocardiography (ECG)-gated contrast-enhanced cardiac CT in the assessment of cardiac lead perforation. METHODS: This retrospective study was approved by the ethics review board of Sun Yat-Sen Memorial Hospital at Sun Yat-Sen University (Guangzhou, China), and the need to obtain informed consent was waived. Between May 2010 and Oct 2017, 52 patients were clinically suspected to have a cardiac lead perforation and received chest radiography, TTE and ECG-gated contrast-enhanced cardiac CT. Among them, 13 patients were identified as having cardiac lead perforation. The diagnostic performances of these three modalities were evaluated by receiver-operating characteristic (ROC) curves using a composite reference standard of surgical and electrophysiological results and clinical follow-up. The areas under ROCs (AUROCs) were compared with the McNemar test. RESULTS: The accuracies of chest radiography, TTE and ECG-gated contrast-enhanced cardiac CT imaging for the diagnosis of cardiac lead perforation were 73.1%, 82.7% and 98.1%, respectively. ECG-gated contrast-enhanced cardiac CT had a higher AUROC than chest radiography (p < 0.001) and TTE (p < 0.001). CONCLUSIONS: ECG-gated contrast-enhanced cardiac CT is superior to both chest radiography and TTE imaging for the assessment of cardiac lead perforation. KEY POINTS: • ECG-gated contrast-enhanced cardiac CT has an accuracy of 98.1% in the diagnosis of cardiac lead perforation. • The AUROC of ECG-gated contrast-enhanced cardiac CT is higher than those of chest radiography and TTE imaging. • ECG-gated contrast-enhanced cardiac CT imaging has better diagnostic performance than both chest radiography and TTE imaging for the assessment of cardiac lead perforation.


Assuntos
Técnicas de Imagem Cardíaca/métodos , Traumatismos Cardíacos/diagnóstico por imagem , Ferimentos Penetrantes/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Técnicas de Imagem de Sincronização Cardíaca/métodos , Ecocardiografia/métodos , Eletrocardiografia/métodos , Eletrodos Implantados/efeitos adversos , Análise de Falha de Equipamento/métodos , Feminino , Traumatismos Cardíacos/etiologia , Humanos , Masculino , Pessoa de Meia-Idade , Marca-Passo Artificial/efeitos adversos , Curva ROC , Radiografia Torácica/métodos , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos , Ferimentos Penetrantes/etiologia
5.
Environ Geochem Health ; 38(1): 111-22, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25732906

RESUMO

The objective of this study is to investigate the levels, inter-species-specific, locational differences and seasonal variations of vanadium in sea cucumbers and to validate further several potential factors controlling the distribution of metals in sea cucumbers. Vanadium levels were evaluated in samples of edible sea cucumbers and were demonstrated exhibit differences in different seasons, species and sampling sites. High vanadium concentrations were measured in the sea cucumbers, and all of the vanadium detected was in an organic form. Mean vanadium concentrations were considerably higher in the blood (sea cucumber) than in the other studied tissues. The highest concentration of vanadium (2.56 µg g(-1)), as well as a higher degree of organic vanadium (85.5 %), was observed in the Holothuria scabra samples compared with all other samples. Vanadium levels in Apostichopus japonicus from Bohai Bay and Yellow Sea have marked seasonal variations. Average values of 1.09 µg g(-1) of total vanadium and 0.79 µg g(-1) of organic vanadium were obtained in various species of sea cucumbers. Significant positive correlations between vanadium in the seawater and V org in the sea cucumber (r = 81.67 %, p = 0.00), as well as between vanadium in the sediment and V org in the sea cucumber (r = 77.98 %, p = 0.00), were observed. Vanadium concentrations depend on the seasons (salinity, temperature), species, sampling sites and seawater environment (seawater, sediment). Given the adverse toxicological effects of inorganic vanadium and positive roles in controlling the development of diabetes in humans, a regular monitoring programme of vanadium content in edible sea cucumbers can be recommended.


Assuntos
Pepinos-do-Mar/química , Pepinos-do-Mar/metabolismo , Estações do Ano , Vanádio/análise , Vanádio/metabolismo , Poluentes Químicos da Água/análise , Poluentes Químicos da Água/metabolismo , Animais , China , Especificidade da Espécie , Distribuição Tecidual , Vanádio/química , Poluentes Químicos da Água/química
6.
Sheng Wu Gong Cheng Xue Bao ; 26(4): 454-61, 2010 Apr.
Artigo em Chinês | MEDLINE | ID: mdl-20575432

RESUMO

VP1 is a major antigenic protein of foot-and-mouth disease virus(FMDV), which induces the immune response against FMDV infection, and contains several epitopes of the virus. We designed and chemically synthesized a DNA fragment which encoding a tandem repeat protein of 136-160aa and 198-211aa of a strain of type Asia I FMDV, and cloned the gene of heavy chain constant region of sheep IgG. By using the BamH I, EcoR I and Xho I sites, both genes were cloned into pPROExHTb vector in turn to form a recombinant plasmid pPRO-FshIgG A chimeric protein, named FshIgG, was obtained after transforming the pPRO-FshIgG into Escherichia coli BL21 (DE3) host cell and induced by IPTG. Inoculation with 100 microg FsIgG induced strong neutralizing antibody response in guinea pigs, and FshIgG inoculated guinea pigs were also protected against 200 ID50 FMDV challenge. Our study indicated that the heavy chain constant region of sheep IgG can act as the carrier protein for FMDV peptide epitopes, and FshIgG is a potential multiepitope peptide vaccine candidate to prevent FMDV infection.


Assuntos
Proteínas do Capsídeo/biossíntese , Vírus da Febre Aftosa/imunologia , Imunoglobulina G/genética , Cadeias Pesadas de Imunoglobulinas/genética , Proteínas Recombinantes de Fusão/imunologia , Animais , Anticorpos Antivirais/sangue , Proteínas do Capsídeo/genética , Epitopos/imunologia , Escherichia coli/genética , Escherichia coli/metabolismo , Vírus da Febre Aftosa/genética , Vetores Genéticos/genética , Cobaias , Imunização , Proteínas Recombinantes de Fusão/biossíntese , Proteínas Recombinantes de Fusão/genética , Ovinos , Vacinas Virais/genética , Vacinas Virais/imunologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA