1.
J Am Heart Assoc ; 10(20): e022217, 2021 10 19.
Artigo em Inglês | MEDLINE | ID: mdl-34612085

RESUMO

Background We have previously developed an intraprocedural automatic arrhythmia-origin localization (AAOL) system to identify idiopathic ventricular arrhythmia origins in real time using a 3-lead ECG. The objective was to assess the localization accuracy of ventricular tachycardia (VT) exit and premature ventricular contraction (PVC) origin sites in patients with structural heart disease using the AAOL system. Methods and Results In retrospective and prospective case series studies, a total of 42 patients who underwent VT/PVC ablation in the setting of structural heart disease were recruited at 2 different centers. The AAOL system combines 120-ms QRS integrals of 3 leads (III, V2, V6) with pace mapping to predict VT exit/PVC origin site and projects that site onto the patient-specific electroanatomic mapping surface. VT exit/PVC origin sites were clinically identified by activation mapping and/or pace mapping. The localization error of the VT exit/PVC origin site was assessed by the distance between the clinically identified site and the estimated site. In the retrospective study of 19 patients with structural heart disease, the AAOL system achieved a mean localization accuracy of 6.5±2.6 mm for 25 induced VTs. In the prospective study with 23 patients, mean localization accuracy was 5.9±2.6 mm for 26 VT exit and PVC origin sites. There was no difference in mean localization error in epicardial sites compared with endocardial sites using the AAOL system (6.0 versus 5.8 mm, P=0.895). Conclusions The AAOL system achieved accurate localization of VT exit/PVC origin sites in patients with structural heart disease; its performance is superior to current systems, and thus, it promises to have potential clinical utility.


Assuntos
Eletrocardiografia , Taquicardia Ventricular , Complexos Ventriculares Prematuros , Ablação por Cateter , Humanos , Estudos Prospectivos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Taquicardia Ventricular/diagnóstico por imagem , Taquicardia Ventricular/cirurgia , Complexos Ventriculares Prematuros/diagnóstico por imagem , Complexos Ventriculares Prematuros/cirurgia
2.
JACC Clin Electrophysiol ; 7(3): 395-407, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33736758

RESUMO

OBJECTIVES: The objective of this study was to present a new system, the Automatic Arrhythmia Origin Localization (AAOL) system, which used incomplete electroanatomic mapping (EAM) for localization of idiopathic ventricular arrhythmia (IVA) origin on the patient-specific geometry of left ventricular, right ventricular, and neighboring vessels. The study assessed the accuracy of the system in localizing IVA source sites on cardiac structures where pace mapping is challenging. BACKGROUND: An intraprocedural automated site of origin localization system was previously developed to identify the origin of early left ventricular activation by using 12-lead electrocardiograms (ECGs). However, it has limitations, as it could not identify the site of origin in the right ventricle and relied on acquiring a complete EAM. METHODS: Twenty patients undergoing IVA catheter ablation had a 12-lead ECG recorded during clinical arrhythmia and during pacing at various locations identified on EAM geometries. The new system combined 3-lead (III, V2, and V6) 120-ms QRS integrals and patient-specific EAM geometry with pace mapping to predict the site of earliest ventricular activation. The predicted site was projected onto EAM geometry. RESULTS: Twenty-three IVA origin sites were clinically identified by activation mapping and/or pace mapping (8, right ventricle; 15, left ventricle, including 8 from the posteromedial papillary muscle, 2 from the aortic root, and 1 from the distal coronary sinus). The new system achieved a mean localization accuracy of 3.6 mm for the 23 mapped IVAs. CONCLUSIONS: The new intraprocedural AAOL system achieved accurate localization of IVA origin in ventricles and neighboring vessels, which could facilitate ablation procedures for patients with IVAs.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Arritmias Cardíacas/diagnóstico , Eletrocardiografia , Humanos , Estudos Prospectivos , Taquicardia Ventricular/cirurgia
3.
Circ Arrhythm Electrophysiol ; 13(7): e008262, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32538133

RESUMO

BACKGROUND: To facilitate ablation of ventricular tachycardia (VT), an automated localization system to identify the site of origin of left ventricular activation in real time using the 12-lead ECG was developed. The objective of this study was to prospectively assess its accuracy. METHODS: The automated site of origin localization system consists of 3 steps: (1) localization of ventricular segment based on population templates, (2) population-based localization within a segment, and (3) patient-specific site localization. Localization error was assessed by the distance between the known reference site and the estimated site. RESULTS: In 19 patients undergoing 21 catheter ablation procedures of scar-related VT, site of origin localization accuracy was estimated using 552 left ventricular endocardial pacing sites pooled together and 25 VT-exit sites identified by contact mapping. For the 25 VT-exit sites, localization error of the population-based localization steps was within 10 mm. Patient-specific site localization achieved accuracy of within 3.5 mm after including up to 11 pacing (training) sites. Using 3 remotes (67.8±17.0 mm from the reference VT-exit site), and then 5 close pacing sites, resulted in localization error of 7.2±4.1 mm for the 25 identified VT-exit sites. In 2 emulated clinical procedure with 2 induced VTs, the site of origin localization system achieved accuracy within 4 mm. CONCLUSIONS: In this prospective validation study, the automated localization system achieved estimated accuracy within 10 mm and could thus provide clinical utility.


Assuntos
Potenciais de Ação , Eletrocardiografia , Sistema de Condução Cardíaco/fisiopatologia , Frequência Cardíaca , Taquicardia Ventricular/diagnóstico , Adulto , Idoso , Idoso de 80 Anos ou mais , Automação , Ablação por Cateter , Técnicas Eletrofisiológicas Cardíacas , Feminino , Sistema de Condução Cardíaco/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes , Processamento de Sinais Assistido por Computador , Taquicardia Ventricular/fisiopatologia , Taquicardia Ventricular/cirurgia , Fatores de Tempo