Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
2.
Ann Surg Oncol ; 31(6): 3916-3925, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38472677

RESUMO

BACKGROUND: Wire localisation (WL) is the "gold standard" localisation technique for wide local excision (WLE) of non-palpable breast lesions but has disadvantages that have led to the development of wireless techniques. This study compared the cost-effectiveness of radar localisation (RL) to WL. METHODS: This was a single-institution study of 110 prospective patients with early-stage breast cancer undergoing WLE using RL with the SCOUT® Surgical Guidance System (2021-2023) compared with a cohort of 110 patients using WL. Margin status, re-excision rates, and surgery delays associated with preoperative localisation were compared. Costs from a third-party payer perspective in Australian dollars (AUD$) calculated by using microcosting, break-even point, and cost-utility analyses. RESULTS: A total of 110 WLEs using RL cost a total of AUD$402,281, in addition to the device cost of AUD$77,150. The average additional cost of a surgery delay was AUD$2318. Use of RL reduced the surgery delay rate by 10% (p = 0.029), preventing 11 delays with cost savings of AUD$25,496. No differences were identified in positive margin rates (RL: 11.8% vs. WL: 17.3%, p = 0.25) or re-excision rates (RL: 14.5% vs. WL: 21.8%, p = 0.221). In total, 290 RL cases are needed to break even. The cost of WLE using RL was greater than WL by AUD$567. There was a greater clinical benefit of 1.15 quality-adjusted life-years (QALYs) and an incremental cost-utility ratio of AUD$493 per QALY favouring RL. CONCLUSIONS: Routine use of RL was a more cost-effective intervention than WL. Close to 300 RL cases are likely needed to be performed to recover costs of the medical device. CLINICAL TRIAL REGISTRATION: ACTRN12624000068561.


Assuntos
Neoplasias da Mama , Análise Custo-Benefício , Humanos , Neoplasias da Mama/cirurgia , Neoplasias da Mama/economia , Neoplasias da Mama/patologia , Feminino , Estudos Prospectivos , Pessoa de Meia-Idade , Seguimentos , Mastectomia Segmentar/economia , Mastectomia Segmentar/métodos , Idoso , Margens de Excisão , Prognóstico , Anos de Vida Ajustados por Qualidade de Vida , Austrália , Cirurgia Assistida por Computador/economia , Cirurgia Assistida por Computador/métodos , Adulto
3.
Ann Surg Oncol ; 30(11): 6520-6527, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37402976

RESUMO

BACKGROUND: The methods for sentinel lymph node (SLN) biopsy in breast cancer have been variable in type and number of tracers. Some units have abandoned the use of blue dye (BD) due to adverse reactions. Fluorescence-guided biopsy with indocyanine green (ICG) is a relatively novel technique. This study compared the clinical efficacy and costs between novel dual tracer ICG and radioisotope (ICG-RI) with "gold standard" BD and radioisotope (BD-RI). METHODS: Single-surgeon study of 150 prospective patients with early breast cancer undergoing SLN biopsy (2021-2022) using ICG-RI compared with a retrospective cohort of 150 consecutive previous patients using BD-RI. Number of SLNs identified, rate of failed mapping, identification of metastatic SLNs, and adverse reactions were compared between techniques. Cost-minimisation analysis performed by using Medicare item numbers and micro-costing analysis. RESULTS: Total number of SLNs identified with ICG-RI and BD-RI was 351 and 315, respectively. Mean number of SLNs identified with ICG-RI and BD-RI was 2.3 (standard deviation [SD] 1.4) and 2.1 (SD 1.1), respectively (p = 0.156). There were no cases of failed mapping with either dual technique. Metastatic SLNs were identified in 38 (25.3%) ICG-RI patients compared with 30 (20%) BD-RI patients (p = 0.641). There were no adverse reactions to ICG, whereas four cases of skin tattooing and anaphylaxis were associated with BD (p = 0.131). ICG-RI cost an additional AU$197.38 per case in addition to the initial cost for the imaging system. CLINICAL TRIAL REGISTRATION:  ACTRN12621001033831. CONCLUSIONS: Novel tracer combination, ICG-RI, provided an effective and safe alternative to "gold standard" dual tracer. The caveat was the significantly greater costs associated with ICG.


Assuntos
Neoplasias da Mama , Linfonodo Sentinela , Idoso , Feminino , Humanos , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/cirurgia , Neoplasias da Mama/patologia , Corantes , Corantes Fluorescentes , Verde de Indocianina , Linfonodos/patologia , Medicare , Estudos Prospectivos , Radioisótopos , Estudos Retrospectivos , Linfonodo Sentinela/diagnóstico por imagem , Linfonodo Sentinela/cirurgia , Linfonodo Sentinela/patologia , Biópsia de Linfonodo Sentinela/métodos , Estados Unidos
4.
J Plast Reconstr Aesthet Surg ; 75(9): 3014-3021, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35710777

RESUMO

BACKGROUND: Mastectomy skin flap necrosis is a major complication of skin- or nipple-sparing mastectomy. Indocyanine green angiography (ICGA) is a novel technology that can identify flaps at risk of necrosis, but there is paucity of cost-effectiveness data particularly in the Australian context. We evaluated its cost-effectiveness in breast reconstruction surgery. METHODS: Single-institution retrospective study of 295 implant-based breast reconstructions using ICGA compared with 228 reconstructions without ICGA from 2015 to 2020. Costs were calculated using Medicare item numbers and micro-costing analysis. Break-even point analysis determined the number needed to break-even. Cost-utility analysis compared probabilities of ischaemic complications and utility estimates derived from surveys of surgeons to fit into a decision model. RESULTS: There were 295 breast reconstructions using ICGA with a total cost of AU$164,657. The average cost of treating an ischaemic complication was AU$21,375. Use of ICGA reduced the ischaemic complication rate from 14.9% to 8.8%. Ischaemic complications were prevented in 18 breasts resulting in gross cost savings of AU$384,745 and net savings of AU$220,088. Three hundred eighteen cases using ICGA are needed to break-even. The decision model demonstrated a baseline cost difference of AU$1,179, a quality-adjusted life-years (QALY) difference of 1.77, and an incremental cost-utility ratio (ICUR) of AU$656 per QALY favouring ICGA. CONCLUSIONS: Routine use of ICGA during implant-based breast reconstruction is a cost-effective intervention for the reduction of ischaemic complications in the Australian setting. ICGA use was associated with a gain of 1.77 additional years of perfect health at a cost of AU$656 more per year.


Assuntos
Neoplasias da Mama , Mamoplastia , Idoso , Angiografia/métodos , Austrália , Análise Custo-Benefício , Feminino , Humanos , Verde de Indocianina , Mamoplastia/métodos , Mastectomia , Medicare , Necrose/prevenção & controle , Complicações Pós-Operatórias/prevenção & controle , Estudos Retrospectivos , Estados Unidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA