Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
JACC Clin Electrophysiol ; 8(4): 480-494, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35450603

RESUMO

OBJECTIVES: This study sought to describe the utility of automated conduction velocity mapping (ACVM) in ventricular tachycardia (VT) ablation. BACKGROUND: Identification of areas of slowed conduction velocity (CV) is critical to our understanding of VT circuits and their underlying substrate. Recently, an ACVM called Coherent Mapping (Biosense Webster Inc) has been developed for atrial mapping. However, its utility in VT mapping has not been described. METHODS: Patients with paired high-density VT activation and substrate maps were included. ACVM was applied to paired VT activation and substrate maps to assess regional CV and activation patterns. A combination of ACVM, traditional local activation time maps, electrogram analysis, and off-line calculated CV using triangulation were used to characterize zones of slowed conduction during VT and in substrate mapping. RESULTS: Fifteen patients were included in the study. In all cases, ACVM identified slow CV within the putative VT isthmus, which colocalized to the VT isthmus identified with entrainment. The dimensions of the VT isthmus with local activation time mapping were 37.8 ± 13.7 mm long and 8.7 ± 4.2 mm wide. In comparison, ACVM produced an isthmus that was shorter (length: 25.1 ± 10.6 mm; mean difference: 12.8; 95% CI: 7.5-18.0; P < 0.01) and wider (width: 18.8 ± 8.1 mm; mean difference: 10.1; 95% CI: 6.1-14.2; P < 0.01). In VT, the CV using triangulation at the entrance (8.0 ± 3.6 cm/s) and midisthmus (8.1 ± 4.3 cm/s) was not significantly different (P = 0.92) but was significantly faster at the exit (16.2 ± 9.7 cm/s; P < 0.01). In the paired substrate analysis, traditional local activation time isochronal mapping identified 6.3 ± 2.0 deceleration zones. In contrast, ACVM identified a median of 0 deceleration zones (IQR: 0-1; P < 0.01). CONCLUSIONS: ACVM is a novel complementary tool that can be used to accurately resolve complex VT circuits and identify slow conduction zones in VT but has limited accuracy in identifying slowed conduction during substrate-based mapping.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Arritmias Cardíacas , Ablação por Cateter/métodos , Sistema de Condução Cardíaco , Frequência Cardíaca/fisiologia , Humanos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA