Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Thromb Res ; 221: 1-6, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36427439

RESUMO

BACKGROUND: A large proportion of patients experience functional limitations after an acute episode of venous thromboembolism (VTE). Recently, the post-VTE functional status (PVFS) scale was proposed to capture these limitations. We performed a prospective cohort study to validate this scale. METHODS: The PVFS scale, PROMIS physical function 10a, EQ-5D-5L, and disease-specific quality of life (VEINES-QOL/Sym, PEmb-QoL) were assessed within three weeks of VTE diagnosis and after a median (IQR) follow-up of 13.4 (12.7-15.9) weeks. To evaluate construct validity of the PVFS scale, we determined correlations of PVFS scale with the other health measurements and investigated differences in patients above/below 70 years. Responsiveness was evaluated with a linear regression model, predicting change in PROMIS with change in PVFS scale. RESULTS: We included 211 patients (median (IQR) age: 55.1 (44.1-67.6) years, 40 % women). Pulmonary embolism was diagnosed in 105 (49.8 %) patients and 62.6 % of events were unprovoked. The PVFS scale correlated with PROMIS physical function (Spearman's rho (r): -0.67 and -0.63, p < 0.001) and EQ-5D-5L index (r = -0.61 and -0.61, p < 0.001) at baseline and follow-up. Furthermore, PVFS correlated moderately to strongly with disease-specific quality of life. Patients >70 years had significantly higher PVFS grades at follow-up (median (IQR): 2 (0-3) vs. 1 (0-2), p = 0.010). Changes in PVFS scale over time were significantly associated with changes in PROMIS physical function. CONCLUSIONS: The PVFS scale showed adequate construct validity and responsiveness in a prospective cohort study of patients with VTE, suggesting that it can be incorporated as additional health measurement and outcome parameter in research and clinical practice.


Assuntos
Qualidade de Vida , Tromboembolia Venosa , Humanos , Feminino , Pessoa de Meia-Idade , Masculino , Tromboembolia Venosa/diagnóstico , Estudos Prospectivos , Estado Funcional , Psicometria , Inquéritos e Questionários
2.
Eur Surg Res ; 57(3-4): 171-185, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27434273

RESUMO

BACKGROUND: Heterotopic heart transplantation (HHT) in rodent animal models represents an important technique enabling studies on organ transplantation immunology and pharmaceutical development. Recent investigations used nonworking HHT designs, with the left ventricle (LV) bypassed in the anastomosis system. In spite of their principal success, the lack of orthogonal ventricular filling leads to myocardial atrophy. However, when focusing on the cellular and molecular mechanisms involved in the in vivo remodeling of the myocardium or cell-based cardiovascular implants, a nonworking model is suboptimal as it lacks the native-analogous hemodynamic and metabolic situation. Here we present the hemodynamic and electrical assessment of a biventricularly loaded murine HHT method without the need for a combined heart-lung transplantation approach. METHODS: Heterotopic transplantations (n = 13) were performed on C57BL/6J-(H-2b) inbred mice (n = 13 donors, n = 13 recipients) by creating end-to-side anastomoses between the donors' cranial vena cava (CrVC) and the recipients' abdominal caudal vena cava (CVC), between the donors' ascending aorta and the recipients' abdominal aorta (aAo), and between the grafts' pulmonary trunk and the left atrium. After transplantation, a hemodynamic assessment using echocardiography (including 2D speckle tracking analysis) and electrocardiography was performed. RESULTS: The loaded HHT procedure in the mice was performed with an overall success rate of 61%. In 3 of the remaining 5 cases, only atrial function was restored. The median duration of the entire surgical procedure for the recipient animal was 190 (IQR 180-250) min. The mean heart rate in the loaded HHT group was 355 ± 6 bpm in comparison to the control group with an in situ heart rate of 418 ± 61 bpm. A native-like closing and opening pattern of the aortic and mitral valves (visible on both 2D and M-mode images) was observed, confirming a native-analogous loading of the LV. Pulsed-wave Doppler provided visualization of the flow across the region of anastomoses between the pulmonary trunk and the left atrium, reaching a mean maximum velocity of 382 ± 12 mm/s. Exemplary 2D speckle tracking analysis of the LV free wall and interventricular septum revealed some differences in vector directions in one animal when compared to the orthotopic native heart, indicating an asynchronous movement of the LV. CONCLUSIONS: These results demonstrate the technical (micro)surgical feasibility of a fully loaded HHT procedure in the murine model without using a combined heart-lung transplantation approach. The acute hemodynamic performance of the HHT grafts approximated the native orthotopic situation. This model may open up new options for the investigation of cellular and molecular questions in the murine cardiovascular in vivo system in the near future.


Assuntos
Transplante de Coração/métodos , Hemodinâmica , Transplante Heterotópico/métodos , Anastomose Cirúrgica , Animais , Ecocardiografia , Feminino , Ventrículos do Coração , Camundongos , Camundongos Endogâmicos C57BL , Modelos Animais
3.
BMC Pediatr ; 15: 18, 2015 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-25884954

RESUMO

BACKGROUND: Since an objective description is essential to determine infant's postnatal condition and efficacy of interventions, two scores were suggested in the past but weren't tested yet: The Specified-Apgar uses the 5 items of the conventional Apgar score; however describes the condition regardless of gestational age (GA) or resuscitative interventions. The Expanded-Apgar measures interventions needed to achieve this condition. We hypothesized that the combination of both (Combined-Apgar) describes postnatal condition of preterm infants better than either of the scores alone. METHODS: Scores were assessed in preterm infants below 32 completed weeks of gestation. Data were prospectively collected in 20 NICU in 12 countries. Prediction of poor outcome (death, severe/moderate BPD, IVH, CPL and ROP) was used as a surrogate parameter to compare the scores. To compare predictive value the AUC for the ROC was calculated. RESULTS: Of 2150 eligible newborns, data on 1855 infants with a mean GA of 28(6/7) ± 2(3/7) weeks were analyzed. At 1 minute, the Combined-Apgar was significantly better in predicting poor outcome than the Specified- or Expanded-Apgar alone. Of infants with a very low score at 5 or 10 minutes 81% or 100% had a poor outcome, respectively. In these infants the relative risk (RR) for perinatal mortality was 24.93 (13.16-47.20) and 31.34 (15.91-61.71), respectively. CONCLUSION: The Combined-Apgar allows a more appropriate description of infant's condition under conditions of modern neonatal care. It should be used as a tool for better comparison of group of infants and postnatal interventions. TRIAL REGISTRATION: clinicaltrials.gov Protocol Registration System (NCT00623038). Registered 14 February 2008.


Assuntos
Índice de Apgar , Recém-Nascido Prematuro , Salas de Parto , Feminino , Idade Gestacional , Humanos , Lactente , Mortalidade Infantil , Recém-Nascido , Gravidez , Prognóstico , Fatores de Risco
4.
J Long Term Eff Med Implants ; 21(4): 299-319, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-22577997

RESUMO

Six Talent stent-grafts were harvested at reoperations (N=5) and autopsy (N=1). The explants were observed nondestructively, including gross morphology, X-rays, CT scans and closed pressure system analysis. The Nitinol frames in three devices harvested at reoperations and another harvested at autopsy were intact. One had a stent fracture of the proximal bare stent, and one had a wire fracture of a thin proximal external supporting stent as well as a hole in the fabric just above the bifurcation. For the three devices structurally intact, reoperations were performed for a type 1A endoleak (one patient) and aorto-enteric fistulas (two patients). The healing characteristics were poor or absent. The fabric in the main body of the grafts harvested after aorto-enteric fistula was devoid of biological deposits. Two of the grafts harvested at reoperation demonstrated fabric holes of up to 4 mm 2. The device obtained at autopsy showed an almost continuous internal capsule with variable thickness. The luminal surface was smooth, but the capsule detached easily. The devices explanted at reoperations showed various levels of impaired biofunctionality associated with adverse outcomes. The stent-graft retrieved from autopsy was intact.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular , Análise de Falha de Equipamento , Idoso , Idoso de 80 Anos ou mais , Remoção de Dispositivo , Evolução Fatal , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reoperação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA