Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Zhonghua Wei Chang Wai Ke Za Zhi ; 27(5): 516-520, 2024 May 25.
Artigo em Chinês | MEDLINE | ID: mdl-38778693

RESUMO

Gastric cancer ranks as the third most prevalent malignant tumor in our nation, imposing a substantial health and economic burden. The occurrence of postoperative complications in gastric cancer not only hinders patient recovery but also significantly increases the medical expenditures of patients, contributing supplementary health economic challenges to both society and healthcare institutions. Conducting health economic analysis on postoperative complications in gastric cancer provides evidence for the formulation of health policies, offers guidance for hospital cost control, and furnishes economic insights for the development of new technologies in the prevention and treatment of complications. This paper, through a thorough review of domestic and international literature, comprehensively examines the impact of complication severity on healthcare expenses, delineates the principal contributors to healthcare costs in patients with postoperative complications, and proposes practical strategies to alleviate the health economic burden resulting from such complications. Furthermore, this study delves into and analyzes the health economic considerations associated with postoperative complications within the framework of the Diagnosis Related Groups (DRG) billing model.


Assuntos
Custos de Cuidados de Saúde , Complicações Pós-Operatórias , Neoplasias Gástricas , Humanos , Neoplasias Gástricas/cirurgia , Neoplasias Gástricas/economia , Complicações Pós-Operatórias/economia , Gastos em Saúde , Efeitos Psicossociais da Doença
2.
Artigo em Chinês | MEDLINE | ID: mdl-38296241

RESUMO

In September 8th, 2021, a male patient (aged 18 years) with severe destructive injuries of high-voltage electric burns in the head, face, and neck was admitted to General Hospital of Taiyuan Iron Steel (Group) Co., Ltd. Based on the economic theory of flaps, the flap donor site and transplantation method were optimized and evaluated before surgery, and then debridement of head, face, and neck wounds+removal of necrotic skull+free transplantation of super large latissimus dorsi myocutaneous flap+thin intermediate thickness skin graft transplantation from the left thigh was performed. The extra large flap donor site wound was sutured directly. This surgery reduced the adverse consequences of the flap donor site on the premise of ensure of repair effect. After operation, the patient's condition was stable, the flap and skin graft survived well, the repair effect of wound was well, the scar in the flap donor area was relatively mild, and the upper limb had no dysfunction.


Assuntos
Queimaduras por Corrente Elétrica , Procedimentos de Cirurgia Plástica , Lesões dos Tecidos Moles , Humanos , Masculino , Queimaduras por Corrente Elétrica/cirurgia , Transplante de Pele , Lesões dos Tecidos Moles/cirurgia , Retalhos Cirúrgicos/cirurgia , Cicatrização , Adolescente
3.
Cancers (Basel) ; 14(20)2022 Oct 13.
Artigo em Inglês | MEDLINE | ID: mdl-36291787

RESUMO

Recently, convolutional neural network (CNN) models have been proposed to automate the assessment of breast density, breast cancer detection or risk stratification using single image modality. However, analysis of breast density using multiple mammographic types using clinical data has not been reported in the literature. In this study, we investigate pre-trained EfficientNetB0 deep learning (DL) models for automated assessment of breast density using multiple mammographic types with and without clinical information to improve reliability and versatility of reporting. 120,000 for-processing and for-presentation full-field digital mammograms (FFDM), digital breast tomosynthesis (DBT), and synthesized 2D images from 5032 women were retrospectively analyzed. Each participant underwent up to 3 screening examinations and completed a questionnaire at each screening encounter. Pre-trained EfficientNetB0 DL models with or without clinical history were optimized. The DL models were evaluated using BI-RADS (fatty, scattered fibroglandular densities, heterogeneously dense, or extremely dense) versus binary (non-dense or dense) density classification. Pre-trained EfficientNetB0 model performances were compared using inter-observer and commercial software (Volpara) variabilities. Results show that the average Fleiss' Kappa score between-observers ranged from 0.31-0.50 and 0.55-0.69 for the BI-RADS and binary classifications, respectively, showing higher uncertainty among experts. Volpara-observer agreement was 0.33 and 0.54 for BI-RADS and binary classifications, respectively, showing fair to moderate agreement. However, our proposed pre-trained EfficientNetB0 DL models-observer agreement was 0.61-0.66 and 0.70-0.75 for BI-RADS and binary classifications, respectively, showing moderate to substantial agreement. Overall results show that the best breast density estimation was achieved using for-presentation FFDM and DBT images without added clinical information. Pre-trained EfficientNetB0 model can automatically assess breast density from any images modality type, with the best results obtained from for-presentation FFDM and DBT, which are the most common image archived in clinical practice.

4.
J Appl Microbiol ; 129(2): 345-355, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32091657

RESUMO

AIMS: Paclitaxel is a type of broad-spectrum anticancer drug in short supply. The price of acetyl-CoA (17 709 677·4 USD mol-1 ), which is the acetyl group donor for the enzymatic synthesis of the intermediate, baccatin Ⅲ, is still the bottleneck of the mass production of paclitaxel. This study reports a novel acetyl group donor, which could substantially reduce the cost of production. METHODS AND RESULTS: In this study, a substrate spectrum with 14 kinds of representative acetyl-donor substitutes predicted by computer-aided methods was tested in a 10-deacetylbaccatin Ⅲ-10-O-acetyltransferase (DBAT) heterogeneous-expressed open-whole-cell catalytic system. The results of computer prediction and experimental analysis revealed the rule of the acetyl-donor compounds based on this substrate spectrum. N-acetyl-d-glucosamine (30·95 USD mol-1 , about 572 202-fold cheaper than acetyl-CoA) is selected as a suitable substitute under the rule. The yield when using N-acetyl-d-glucosamine as acetyl donor in open-whole-cell catalytic system was 2·13-fold of that when using acetyl-CoA. In the in vivo system, the yield increased 24·17%, which may indicate its cooperation with acetyl-CoA. CONCLUSION: The success of open-whole-cell synthesis and in vivo synthesis of baccatin Ⅲ by adding N-acetyl-d-glucosamine as acetyl substrate demonstrates that it is a useful substrate to improve the yield of baccatin Ⅲ. SIGNIFICANCE AND IMPACT OF THE STUDY: All these findings provided a potential acetyl-donor substitute for acetyl-CoA, as well as a low cost and efficient method of preparing paclitaxel through baccatin Ⅲ semi-synthesis.


Assuntos
Acetilglucosamina/metabolismo , Alcaloides/biossíntese , Acetilcoenzima A/metabolismo , Acetiltransferases/genética , Acetiltransferases/metabolismo , Alcaloides/economia , Antineoplásicos Fitogênicos/biossíntese , Antineoplásicos Fitogênicos/química , Antineoplásicos Fitogênicos/economia , Biocatálise , Paclitaxel/biossíntese , Paclitaxel/química , Paclitaxel/economia , Especificidade por Substrato , Taxoides/economia
5.
Surg Endosc ; 33(7): 2217-2221, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-30327915

RESUMO

BACKGROUND: Robotic-assisted surgery (RAS) with its advantages continues to gain popularity among surgeons. This study analyzed the increased costs of RAS in common surgical procedures using the National Inpatient Sample. METHODS: Retrospective analysis of the 2012-2014 Healthcare Cost and Utilization Project-NIS was performed for the following laparoscopic/robotic procedures: cholecystectomy, ventral hernia repair, right and left hemicolectomy, sigmoidectomy, abdominoperineal resection, and total abdominal hysterectomy (TAH). Patients with additional concurrent procedures were excluded. Costs were compared between the laparoscopic procedures and their RAS counterparts. Total costs and charges for cholecystectomy (the most common procedure in the dataset) were compared based on the payer and characteristics of hospital (region, rural/urban, bed size, and ownership). RESULTS: A total of 91,630 surgeries (87,965 laparoscopic, 3665 robotic) were analyzed. The average cost for the laparoscopic group was $10,227 ± $4986 versus $12,340 ± $5880 for the robotic cases (p < 0.001). The overall and percentage increases for laparoscopic versus robotic for each procedure were as follows: cholecystectomy $9618 versus $10,944 (14%), ventral hernia repair $10,739 versus $13,441 (25%), right colectomy $12,516 versus $15,027 (20%), left colectomy $14,157 versus $17,493 (24%), sigmoidectomy $13,504 versus $16,652 (23%), abdominoperineal resection $17,708 versus $19,605 (11%), and TAH $9368 versus $9923 (6%). Hysterectomy was the only procedure performed primarily using RAS and it was found to have the lowest increase in costs. Increased costs were associated with even higher increases in charges, especially in investor-owned private hospitals. CONCLUSION: RAS is more costly when compared to conventional laparoscopic surgery. Additional costs may be lower in centers that perform a higher volume of RAS. Further analysis of long-term outcomes (including reoperations and readmissions) is needed to better compare the life-long treatment costs for both surgical approaches.


Assuntos
Laparoscopia , Utilização de Procedimentos e Técnicas , Procedimentos Cirúrgicos Robóticos , Procedimentos Cirúrgicos Operatórios , Custos e Análise de Custo , Bases de Dados Factuais , Custos Diretos de Serviços , Feminino , Humanos , Laparoscopia/economia , Laparoscopia/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , Utilização de Procedimentos e Técnicas/economia , Utilização de Procedimentos e Técnicas/estatística & dados numéricos , Estudos Retrospectivos , Procedimentos Cirúrgicos Robóticos/economia , Procedimentos Cirúrgicos Robóticos/estatística & dados numéricos , Procedimentos Cirúrgicos Operatórios/economia , Procedimentos Cirúrgicos Operatórios/métodos , Procedimentos Cirúrgicos Operatórios/estatística & dados numéricos , Estados Unidos
6.
AJR Am J Roentgenol ; 211(1): 217-223, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29792736

RESUMO

OBJECTIVE: The objective of this study is to analyze the incidence of women with breast pain who present to an imaging center and assess the imaging findings, outcomes, and workup costs at breast imaging centers affiliated with one institution. MATERIALS AND METHODS: Demographic characteristics of and imaging findings for female patients presenting with breast pain at three community breast imaging centers between January 1, 2014, and December 31, 2014, were reviewed. Patients who were pregnant, were lactating, had a history of breast cancer, or presented with palpable nipple or skin findings were excluded. RESULTS: A total of 799 patients met the study criteria. Pain was diffuse in 30%, was focal in 30%, and was not localized in 40%. Of the 799 patients with breast pain, 790 (99%) presented for a diagnostic evaluation; 759 (95%) of these evaluated patients had negative findings. A benign sonographic correlate was detected in the area of pain in 5% of patients (39/799). One patient had a single cancer detected in the contralateral asymptomatic breast. When correlations between breast pain and the presence of cancer in the study patients were compared with the concurrent cancer detection rate in the screening population (5.5 cases per 1000 examinations performed), breast pain was not found to be a sign of breast cancer (p = 0.027). Patients younger than 40 years (316/799) underwent a total of 454 workup studies for breast pain; all findings were benign, and the cost of these studies was $87,322. Patients 40 years or older (483/799) underwent 745 workup studies, for a cost of $152,732. CONCLUSION: Breast pain represents an area of overutilization of health care resources. For female patients who present with pure breast pain, breast imaging centers should consider the following imaging protocols and education for referring physicians: an annual screening mammogram should be recommended for women 40 years or older, and reassurance without imaging should be offered to patients younger than 40 years.


Assuntos
Mastodinia/diagnóstico por imagem , Procedimentos Desnecessários/economia , Revisão da Utilização de Recursos de Saúde , Adulto , Idoso , Meios de Contraste , Feminino , Humanos , Imageamento por Ressonância Magnética/economia , Mamografia/economia , Pessoa de Meia-Idade , Estudos Retrospectivos , Ultrassonografia Mamária/economia , Estados Unidos
7.
Ann Surg Oncol ; 25(7): 1953-1960, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29667115

RESUMO

PURPOSE: This study was designed to present the secondary imaging endpoints of the trial for evaluating mammogram (MMG), ultrasound (US) and image guided biopsy (IGBx) assessment of pathologic complete response (pCR) in breast cancer (BC) patients undergoing neoadjuvant chemotherapy (NAC). METHODS: Patients with T1-3, N0-3, M0 triple-negative or HER2-positive BC who received NAC were enrolled in an Institutional Review Board-approved prospective, clinical trial. Patients underwent US and MMG at baseline and after NAC. Images were evaluated for residual abnormality and to determine modality for IGBx [US-guided (USG) or stereotactic guided (SG)]. Fine-needle aspiration and 9-G, vacuum-assisted core biopsy (VACBx) of tumor bed was performed after NAC and was compared with histopathology at surgery. RESULTS: Forty patients were enrolled. Median age was 50.5 (range 26-76) years; median baseline tumor size was 2.4 cm (range 0.8-6.3) and 1 cm (range 0-5.5) after NAC. Nineteen patients had pCR: 6 (32%) had residual Ca2+ presurgery, 5 (26%) residual mass, 1 (5%) mass with calcifications, and 7 (37%) no residual imaging abnormality. Sensitivity, specificity, and accuracy of US, MMG, and IGBx for pCR were 47/95/73%, 53/90/73%, and 100/95/98%, respectively. Twenty-five (63%) patients had SGBx and 15 (37%) had US-guided biopsy (USGBx). Median number of cores was higher with SGBx (12, range 6-14) than with USGBx (8, range 4-12), p < 0.002. Positive predictive value for pCR was significantly higher for SG VACBx than for USG VACBx (100 vs. 60%, p < 0.05). CONCLUSIONS: SG VACBx is the preferred IGBx modality for identifying patients with pCR for trials testing the safety of eliminating surgery.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Biópsia Guiada por Imagem/métodos , Mamografia/métodos , Terapia Neoadjuvante , Ultrassonografia Mamária/métodos , Adulto , Idoso , Biópsia por Agulha Fina , Neoplasias da Mama/tratamento farmacológico , Quimioterapia Adjuvante , Estudos de Viabilidade , Feminino , Seguimentos , Humanos , Pessoa de Meia-Idade , Prognóstico , Estudos Prospectivos
8.
Br J Radiol ; 89(1065): 20160401, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27384241

RESUMO

OBJECTIVE: To compare the incremental cancer detection rate (ICDR) using bilateral whole-breast ultrasonography (BWBUS) vs dynamic contrast-enhanced MRI in patients with primary breast cancer. METHODS: A retrospective database search in a single institution identified 259 patients with breast cancer diagnosed from January 2011 to August 2014 who underwent mammography, BWBUS and MRI before surgery. Patient characteristics, tumour characteristics and lesions seen on each imaging modality were recorded. The sensitivity, specificity and accuracy for each modality were calculated. ICDRs according to index tumour histology and receptor status were also evaluated. The effect of additional cancer detection on surgical planning was obtained from the medical records. RESULTS: A total of 266 additional lesions beyond 273 index malignancies were seen on at least 1 modality, of which 121 (45%) lesions were malignant and 145 (55%) lesions were benign. MRI was significantly more sensitive than BWBUS (p = 0.01), while BWBUS was significantly more accurate and specific than MRI (p < 0.0001). Compared with mammography, the ICDRs using BWBUS and MRI were significantly higher for oestrogen receptor-positive and triple-negative cancers, but not for human epidermal growth factor receptor 2-positive cancers. 22 additional malignant lesions in 18 patients were seen on MRI only. Surgical planning remained unchanged in 8 (44%) of those 18 patients. CONCLUSION: MRI was more sensitive than BWBUS, while BWBUS was more accurate and specific than MRI. MRI-detected additional malignant lesions did not change surgical planning in almost half of these patients. ADVANCES IN KNOWLEDGE: BWBUS may be a cost-effective and practical tool in breast cancer staging.


Assuntos
Neoplasias da Mama/diagnóstico , Biópsia por Agulha/economia , Biópsia por Agulha/normas , Neoplasias da Mama/economia , Análise Custo-Benefício , Detecção Precoce de Câncer , Feminino , Humanos , Biópsia Guiada por Imagem/economia , Biópsia Guiada por Imagem/normas , Imageamento por Ressonância Magnética/economia , Imageamento por Ressonância Magnética/normas , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Cuidados Pré-Operatórios , Estudos Retrospectivos , Sensibilidade e Especificidade , Ultrassonografia Mamária/economia , Ultrassonografia Mamária/normas
9.
AJR Am J Roentgenol ; 206(2): 270-5, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26491892

RESUMO

OBJECTIVE: Accountable care organizations (ACOs) are being promoted by the Centers of Medicare Services as alternative payment models for radiology reimbursement. Because of its clinical orientation, focus on prevention, standardized reporting, quality orientation through mandatory accreditation, and value demonstration through established outcome metrics, breast imaging offers a unique paradigm for the ACO model in radiology. CONCLUSION: In radiology, breast imaging represents the paradigm for ACOs.


Assuntos
Organizações de Assistência Responsáveis/normas , Neoplasias da Mama/diagnóstico , Mamografia/economia , Medicare/economia , Qualidade da Assistência à Saúde , Organizações de Assistência Responsáveis/economia , Feminino , Humanos , Mamografia/normas , Qualidade da Assistência à Saúde/economia , Reembolso de Incentivo , Estados Unidos , Aquisição Baseada em Valor
10.
Phys Med Biol ; 54(21): 6691-709, 2009 Nov 07.
Artigo em Inglês | MEDLINE | ID: mdl-19841514

RESUMO

With volume-of-interest (VOI) cone-beam computed tomography (CBCT) imaging, one set of projection images are acquired with the VOI collimator at a regular or high exposure level and the second set of projection images are acquired without the collimator at a reduced exposure level. The high exposure VOI scan data inside the VOI and the low exposure full-field scan data outside the VOI are then combined together to generate composite projection images for image reconstruction. To investigate and quantify scatter reduction, dose saving and image quality improvement in VOI CBCT imaging, a flat panel detector-based bench-top experimental CBCT system was built to measure the dose, the scatter-to-primary ratio (SPR), the image contrast, noise level, the contrast-to-noise ratio (CNR) and the figure of merit (FOM) in the CBCT reconstructed images for two polycarbonate cylinders simulating the small and the large phantoms. The results showed that, compared to the full field CBCT technique, radiation doses for the VOI CBCT technique were reduced by a factor of 1.20 and 1.36 for the small and the large phantoms at the phantom center, respectively, and from 2.7 to 3.0 on the edge of the phantom, respectively. Inside the VOI, the SPRs were substantially reduced by a factor of 6.6 and 10.3 for the small and the large phantoms, the contrast signals were improved by a factor of 1.35 and 1.8, and the noise levels were increased by a factor of 1.27 and 1.6, respectively. As a result, the CNRs were improved by a factor of 1.06 and 1.13 for the small and the large phantoms and the FOM improved by a factor of 1.4 and 1.7, respectively.


Assuntos
Espalhamento de Radiação , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Mama/patologia , Neoplasias da Mama/radioterapia , Calibragem , Desenho de Equipamento , Feminino , Humanos , Mamografia/métodos , Modelos Estatísticos , Método de Monte Carlo , Imagens de Fantasmas , Planejamento da Radioterapia Assistida por Computador/métodos , Raios X
11.
Med Phys ; 36(9): 4007-14, 2009 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-19810473

RESUMO

PURPOSE: In this study, the authors investigated the feasibility of a dual resolution volume-of-interest (VOI) cone beam breast CT technique and compared two implementation approaches in terms of dose saving and scatter reduction. METHODS: With this technique, a lead VOI mask with an opening is inserted between the x-ray source and the breast to deliver x-ray exposure to the VOI while blocking x rays outside the VOI. A CCD detector is used to collect the high resolution projection data of the VOI. Low resolution cone beam CT (CBCT) images of the entire breast, acquired with a flat panel (FP) detector, were used to calculate the projection data outside the VOI with the ray-tracing reprojection method. The Feldkamp-Davis-Kress filtered backprojection algorithm was used to reconstruct the dual resolution 3D images. Breast phantoms with 180 microm and smaller microcalcifications (MCs) were imaged with both FP and FP-CCD dual resolution CBCT systems, respectively. Two approaches of implementing the dual resolution technique, breast-centered approach and VOI-centered approach, were investigated and evaluated for dose saving and scatter reduction with Monte Carlo simulation using a GEANT4 package. RESULTS: The results showed that the breast-centered approach saved more breast absorbed dose than did VOI-centered approach with similar scatter reduction. The MCs in fatty breast phantom, which were invisible with FP CBCT scan, became visible with the FP-CCD dual resolution CBCT scan. CONCLUSIONS: These results indicate potential improvement of the image quality inside the VOI with reduced breast dose both inside and outside the VOI.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Tomografia Computadorizada de Feixe Cônico/métodos , Mamografia/métodos , Algoritmos , Mama/efeitos da radiação , Calcinose/diagnóstico por imagem , Simulação por Computador , Estudos de Viabilidade , Feminino , Humanos , Imageamento Tridimensional/métodos , Método de Monte Carlo , Parafina/química , Imagens de Fantasmas , Doses de Radiação , Espalhamento de Radiação , Software , Raios X
12.
Med Phys ; 35(8): 3482-90, 2008 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-18777908

RESUMO

This work is to demonstrate that high quality cone beam CT images can be generated for a volume of interest (VOI) and to investigate the exposure reduction effect, dose saving, and scatter reduction with the VOI scanning technique. The VOI scanning technique involves inserting a filtering mask between the x-ray source and the breast during image acquisition. The mask has an opening to allow full x-ray exposure to be delivered to a preselected VOI and a lower, filtered exposure to the region outside the VOI. To investigate the effects of increased noise due to reduced exposure outside the VOI on the reconstructed VOI image, we directly extracted the projection data inside the VOI from the full-field projection data and added additional data to the projection outside the VOI to simulate the relative noise increase due to reduced exposure. The nonuniform reference images were simulated in an identical manner to normalize the projection images and measure the x-ray attenuation factor for the object. Regular Feldkamp-Davis-Kress filtered backprojection algorithm was used to reconstruct the 3D images. The noise level inside the VOI was evaluated and compared with that of the full-field higher exposure image. Calcifications phantom and low contrast phantom were imaged. Dose reduction was investigated by estimating the dose distribution in a cylindrical water phantom using Monte Carlo simulation based Geant4 package. Scatter reduction at the detector input was also studied. Our results show that with the exposure level reduced by the VOI mask, the dose levels were significantly reduced both inside and outside the VOI without compromising the accuracy of image reconstruction, allowing for the VOI to be imaged with more clarity and helping to reduce the breast dose. The contrast-to-noise ratio inside the VOI was improved. The VOI images were not adversely affected by noisier projection data outside the VOI. Scatter intensities at the detector input were also shown to decrease significantly both inside and outside the VOI in the projection images, indicating potential improvement of image quality inside the VOI and contribution to dose reduction both inside and outside the VOI.


Assuntos
Algoritmos , Mama/patologia , Tomografia Computadorizada de Feixe Cônico/métodos , Interpretação de Imagem Assistida por Computador/métodos , Método de Monte Carlo , Artefatos , Mama/diagnóstico por imagem , Simulação por Computador , Tomografia Computadorizada de Feixe Cônico/instrumentação , Meios de Contraste , Humanos , Doses de Radiação , Cintilografia
13.
Ma Zui Xue Za Zhi ; 29(2): 596-603, 1991 Jun.
Artigo em Chinês | MEDLINE | ID: mdl-1758252

RESUMO

The laryngeal mask airway (LMA) is a new form of oropharyngeal airway that provides an alternative to endotracheal intubation and face mask anesthesia in certain cases. Once the patient is adequately anesthetised, it can be inserted blindly without recourse to laryngoscopy. The advantages over standard mask anesthesia are: better airway control, minimal leakage of anesthetic gases, and it frees the anesthetist's hands, as no mandibular support is needed. LMA does not guarantee against the risk of aspiration and it is not recommended for use in patients who may have risk of gastric regurgitation. Our preliminary study revealed that a clear and clinical satisfactory airway was obtained in 98.2% of patients. According to the intraoperative respiratory minute volume and arterial blood gases, the patency of the airway did not deteriorate during the course of the anesthesia. Blood pressure and heart rate were compared on induction in group I and II. Succinylcholine 1 mg/kg, thiopentone 4-6 mg/kg and fentanyl 2 micrograms/kg were used in group I while using the same dosage of succinylcholine and thiopentone without fentanyl for group II. We found no significant differences in vital signs between the two groups.


Assuntos
Anestesia Geral/métodos , Máscaras , Respiração , Hemodinâmica , Humanos
14.
Cancer ; 57(6): 1184-91, 1986 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-2417696

RESUMO

Ten cases of large hepatocellular carcinoma (HCC) (largest diameter, 6.5-15 cm) were surgically resected from 3 to 19 days after transcatheter hepatic arterial embolization (TAE) for histologic assessment of the effectiveness. Another two patients, including one with a small HCC (3.5 X 3 X 3 cm) who died of complications, were also studied. The patients' ages ranged from 20 to 64 years, 11 were men and 1 was a woman, and all positive for serum hepatitis B surface antigen. All 11 cases with large HCC were symptomatic before the HCC was clinically diagnosed. Alpha-fetoprotein levels were elevated in ten cases but immediately dropped to normal levels after TAE and resection in eight cases. An effective massive tumor coagulative necrosis of 99% already occurred 3 days after TAE. A necrosis involving more than 95% of the whole tumor mass was demonstrated in eight cases: one was a large HCC taken from an autopsy specimen, and TAE was done three times. This strongly indicates the effectiveness of TAE on the destruction of HCC. However, the presence of viable residual tumors in 11 cases also strongly argues for the necessity for surgical resection whenever it is possible. The failure of a complete necrosis was related to the extracapsular extension, liver invasion, satellite nodules, and portal vein involvement, and probably related to collateral and portal vein blood supply.


Assuntos
Carcinoma Hepatocelular/patologia , Embolização Terapêutica , Artéria Hepática , Neoplasias Hepáticas/patologia , Adulto , Autopsia , Carcinoma Hepatocelular/cirurgia , Carcinoma Hepatocelular/terapia , Feminino , Esponja de Gelatina Absorvível , Humanos , Neoplasias Hepáticas/cirurgia , Neoplasias Hepáticas/terapia , Masculino , Pessoa de Meia-Idade , Necrose/patologia , alfa-Fetoproteínas/análise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA