Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Isr Med Assoc J ; 23(11): 685-689, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34811981

RESUMO

BACKGROUND: Toward the end of 2019, the coronavirus disease-2019 (COVID-19) pandemic began to create turmoil for global health organizations. The illness, caused by the severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2), spreads by droplets and fomites and can rapidly lead to life-threatening lung disease, especially for the old and those with health co-morbidities. Treating orthopedic patients, who presented with COVID-19 while avoiding nosocomial transmission, became of paramount importance. OBJECTIVES: To present relevant methods for pandemic control and hospital accommodation with emphasis on orthopedic surgery. METHODS: We searched search PubMed and Google Scholar electronic databases using the following keywords: COVID-19, SARS-CoV-2, screening tools, personal protective equipment, and surgery triage. RESULTS: We included 25 records in our analysis. The recommendations from these records were divided into the following categories: COVID-19 disease, managing orthopedic surgery in the COVID-19 era, general institution precautions, triage of orthopedic surgeries, preoperative assessment, surgical room setting, personal protection equipment, anesthesia, orthopedic surgery technical precautions, and department stay and rehabilitation. CONCLUSIONS: Special accommodations tailored for each medical facility, based on disease burden and available resources can improve patient and staff safety and reduce elective surgery cancellations. This article will assist orthopedic surgeons during the COVID-19 medical crisis, and possibly for future pandemics.


Assuntos
COVID-19 , Controle de Infecções , Procedimentos Ortopédicos , COVID-19/epidemiologia , COVID-19/prevenção & controle , Protocolos Clínicos , Transmissão de Doença Infecciosa/prevenção & controle , Saúde Global , Humanos , Controle de Infecções/métodos , Controle de Infecções/organização & administração , Salas Cirúrgicas/organização & administração , Inovação Organizacional , Procedimentos Ortopédicos/métodos , Procedimentos Ortopédicos/normas , Procedimentos Ortopédicos/tendências , Equipamento de Proteção Individual , SARS-CoV-2 , Triagem/organização & administração
2.
Int J Comput Assist Radiol Surg ; 6(5): 685-92, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21298490

RESUMO

OBJECTIVE: The most commonly used imaging device for assessment of fracture reduction is the two-dimensional X-ray fluoroscope. Two recently introduced 3D fluoroscopic devices, the Siremobil ISO-C3D (Siemens) and the C-InSight (Mazor Surgical Technologies), enable the surgeon to obtain spatial information for the assessment of articular reduction and hardware placement. The purpose of this study was to assess the reliability and accuracy of these two 3D fluoroscopic systems in measuring articular reduction in a cadaveric tibial plateau fracture. METHODS: Six cadaveric knee specimens were osteotomized at the lateral tibial plateau and fixed with a maximal articular step-off of 0, 1, 2.5, 5 and 7.5 mm. Each specimen was scanned 10 times with two 3D fluoroscopes, the Siremobil ISO-C3D and the C-InSight. The resulting images were reformatted and interpreted for articular displacements at four different locations at the plateau level and were compared with high-resolution CT scans by an independent observer. RESULTS: For the non-displaced fracture, no displacement (mean < 0.1 mm) was observed in either modality. The mean scanning time for the ISO-C3D was 2 min, while each C-InSight scan took 20 s. The readings at four different points along the malreduced fractures were similar for most measurements with either of the two modalities. The C-InSight readings were less accurate than those of the ISO-C3D, relative to the CT scan, but most errors were within clinically acceptable limits (< 2 mm) and used less radiation. CONCLUSIONS: Intraoperative 3D fluoroscopes can detect clinically significant intra-articular step-off with acceptable measurement errors, using newer devices that enable the use of a conventional C-arm and reduced radiation.


Assuntos
Fluoroscopia/métodos , Imageamento Tridimensional/métodos , Fraturas Intra-Articulares/diagnóstico por imagem , Traumatismos do Joelho/diagnóstico por imagem , Monitorização Intraoperatória/métodos , Cadáver , Feminino , Humanos , Fraturas Intra-Articulares/cirurgia , Traumatismos do Joelho/cirurgia , Masculino , Osteotomia/métodos , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA