Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Med Imaging Radiat Oncol ; 63(4): 446-453, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-30874377

RESUMO

INTRODUCTION: Patients with severe aortic stenosis (AS) require multi-detector computed tomography (MDCT) when considered for transcatheter aortic valve implantation (TAVI). Incidental findings on MDCT are common given the age group and region imaged. Our aim was to evaluate the frequency and outcome of incidental findings (IF) identified on MDCT and the impact on survival. METHODS: This single-centre analysis retrospectively reviewed severe AS patients who underwent MDCT during TAVI workup. MDCT reports were reviewed for any IF and defined into three categories: IF of no relevant clinical significance (IF-NoCS), IF of non-immediate clinical significance (IF-NICS) and IF of immediate clinical significance (IF-ICS). Demographics, follow-up of IF and survival were calculated from MDCT date. RESULTS: Two hundred and sixty-five patients underwent MDCT for TAVI suitability (mean age 83 ± 6 years, 52% male). The majority proceeded to TAVI (65%). Renal lesions (25%) and lung nodules (18%) were the most common IF. Fifty-nine patients (22%) had IF-NICS; 39% (23/59) were benign, 59% were not further investigated and one patient had suspected lung cancer. Six patients (2.3%) had IF-ICS and all were diagnosed with lung cancer. During a median follow-up of 272 days, there was no survival difference between patients with IF-ICS or IF-NICS versus patients without IF or IF-NoCS in the overall cohort (P = 0.44) or in TAVI patients (P = 0.88). CONCLUSION: Incidental findings on MDCT are common with one-quarter having IF-ICS or IF-NCIS. Most patients with IF-NICS did not undergo further investigation. Standardized reporting of MDCT may assist in clarifying the need for further investigation which will in turn influence decision and timing to proceed with TAVI.


Assuntos
Estenose da Valva Aórtica/diagnóstico por imagem , Achados Incidentais , Tomografia Computadorizada Multidetectores/métodos , Cuidados Pré-Operatórios/métodos , Substituição da Valva Aórtica Transcateter , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Estudos de Coortes , Feminino , Humanos , Masculino , Estudos Retrospectivos , Análise de Sobrevida
2.
Intern Med J ; 49(3): 297-305, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30091235

RESUMO

Severe aortic stenosis (AS) is the most common form of valvular heart disease in the developed world, with a rising prevalence due to an ageing Australian population. Transcatheter aortic valve implantation (TAVI) offers a less invasive option for the treatment of severe AS, with evidence supporting TAVI compared with medical therapy in inoperable patients and superior with surgical aortic valve replacement (SAVR) in high-risk patients. Equal outcomes have been observed in all-comer intermediate-risk populations. The Heart Team utilises a shared decision-making approach between physicians and surgeons in risk-stratifying patients and reduces the intrinsic bias that may occur if decisions are made in isolation. Geriatric assessment is useful for identifying preoperative frailty, a major risk factor for death post-aortic valve intervention. In severe AS, a decision can be made collaboratively to pursue TAVI, SAVR, a Ross Procedure or conservative management. The learning curve associated with TAVI has improved markedly, with overall complication rates decreasing around the world. Contemporary changes in practice, such as conscious sedation without general anaesthesia, expedited recovery and early discharge, will likely improve cost-effectiveness. In 2018, TAVI is a well-established procedure in Australia that has revolutionised the management of severe AS. In the future, with an expanding elderly population, the number of patients to benefit from transcatheter therapies for severe AS is hypothesised to increase 4-10-fold. Heart Team assessment is crucial in patients with severe AS to direct appropriate management.


Assuntos
Estenose da Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Equipe de Assistência ao Paciente , Complicações Pós-Operatórias/epidemiologia , Substituição da Valva Aórtica Transcateter/tendências , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/mortalidade , Austrália , Análise Custo-Benefício , Tomada de Decisões , Saúde Global , Humanos , Medição de Risco , Fatores de Risco
3.
JACC Cardiovasc Interv ; 7(12): 1400-11, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25523532

RESUMO

OBJECTIVES: This study sought to describe the frequency and clinical impact of acute scaffold disruption and late strut discontinuity of the second-generation Absorb bioresorbable polymeric vascular scaffolds (Absorb BVS, Abbott Vascular, Santa Clara, California) in the ABSORB (A Clinical Evaluation of the Bioabsorbable Everolimus Eluting Coronary Stent System in the Treatment of Patients With De Novo Native Coronary Artery Lesions) cohort B study by optical coherence tomography (OCT) post-procedure and at 6, 12, 24, and 36 months. BACKGROUND: Fully bioresorbable scaffolds are a novel approach to treatment for coronary narrowing that provides transient vessel support with drug delivery capability without the long-term limitations of metallic drug-eluting stents. However, a potential drawback of the bioresorbable scaffold is the potential for disruption of the strut network when overexpanded. Conversely, the structural discontinuity of the polymeric struts at a late stage is a biologically programmed fate of the scaffold during the course of bioresorption. METHODS: The ABSORB cohort B trial is a multicenter single-arm trial assessing the safety and performance of the Absorb BVS in the treatment of 101 patients with de novo native coronary artery lesions. The current analysis included 51 patients with 143 OCT pullbacks who underwent OCT at baseline and follow-up. The presence of acute disruption or late discontinuities was diagnosed by the presence on OCT of stacked, overhung struts or isolated intraluminal struts disconnected from the expected circularity of the device. RESULTS: Of 51 patients with OCT imaging post-procedure, acute scaffold disruption was observed in 2 patients (3.9%), which could be related to overexpansion of the scaffold at the time of implantation. One patient had a target lesion revascularization that was presumably related to the disruption. Of 49 patients without acute disruption, late discontinuities were observed in 21 patients. There were no major adverse cardiac events associated with this finding except for 1 patient who had a non-ischemia-driven target lesion revascularization. CONCLUSIONS: Acute scaffold disruption is a rare iatrogenic phenomenon that has been anecdotally associated with anginal symptoms, whereas late strut discontinuity is observed in approximately 40% of patients and could be viewed as a serendipitous OCT finding of a normal bioresorption process without clinical implications. (ABSORB Clinical Investigation, Cohort B [ABSORB B]; NCT00856856).


Assuntos
Implantes Absorvíveis , Angioplastia Coronária com Balão/instrumentação , Fármacos Cardiovasculares/administração & dosagem , Doença da Artéria Coronariana/terapia , Vasos Coronários/patologia , Stents Farmacológicos , Sirolimo/análogos & derivados , Tomografia de Coerência Óptica , Idoso , Idoso de 80 Anos ou mais , Angioplastia Coronária com Balão/efeitos adversos , Doença da Artéria Coronariana/diagnóstico , Everolimo , Feminino , Humanos , Masculino , Valor Preditivo dos Testes , Desenho de Prótese , Sirolimo/administração & dosagem , Fatores de Tempo , Resultado do Tratamento
4.
EuroIntervention ; 9(6): 709-20, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23628499

RESUMO

AIMS: To assess serially the edge vascular response (EVR) of a bioresorbable vascular scaffold (BVS) compared to a metallic everolimus-eluting stent (EES). METHODS AND RESULTS: Non-serial evaluations of the Absorb BVS at one year have previously demonstrated proximal edge constrictive remodelling and distal edge changes in plaque composition with increase of the percent fibro-fatty (FF) tissue component. The 5 mm proximal and distal segments adjacent to the implanted devices were investigated serially with intravascular ultrasound (IVUS), post procedure, at six months and at two years, from the ABSORB Cohort B1 (n=45) and the SPIRIT II (n=113) trials. Twenty-two proximal and twenty-four distal edge segments were available for analysis in the ABSORB Cohort B1 trial. In the SPIRIT II trial, thirty-three proximal and forty-six distal edge segments were analysed. At the 5-mm proximal edge, the vessels treated with an Absorb BVS from post procedure to two years demonstrated a lumen loss (LL) of 6.68% (-17.33; 2.08) (p=0.027) with a trend toward plaque area increase of 7.55% (-4.68; 27.11) (p=0.06). At the 5-mm distal edge no major changes were evident at either time point. At the 5-mm proximal edge the vessels treated with a XIENCE V EES from post procedure to two years did not show any signs of LL, only plaque area decrease of 6.90% (-17.86; 4.23) (p=0.035). At the distal edge no major changes were evident with regard to either lumen area or vessel remodelling at the same time point. CONCLUSIONS: The IVUS-based serial evaluation of the EVR up to two years following implantation of a bioresorbable everolimus-eluting scaffold shows a statistically significant proximal edge LL; however, this finding did not seem to have any clinical implications in the serial assessment. The upcoming imaging follow-up of the Absorb BVS at three years is anticipated to provide further information regarding the vessel wall behaviour at the edges.


Assuntos
Stents Farmacológicos , Everolimo , Implantes Absorvíveis , Seguimentos , Humanos , Masculino , Sirolimo/administração & dosagem , Resultado do Tratamento
5.
Circ Cardiovasc Interv ; 5(5): 620-32, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23048057

RESUMO

BACKGROUND: Nonserial observations have shown this bioresorbable scaffold to have no signs of area reduction at 6 months and recovery of vasomotion at 1 year. Serial observations at 6 months and 2 years have to confirm the absence of late restenosis or unfavorable imaging outcomes. METHODS AND RESULTS: The ABSORB trial is a multicenter single-arm trial assessing the safety and performance of an everolimus-eluting bioresorbable vascular scaffold. Forty-five patients underwent serial invasive imaging, such as quantitative coronary angiography, intravascular ultrasound, and optical coherence tomography at 6 and 24 months of follow-up. From 6 to 24 months, late luminal loss increased from 0.16±0.18 to 0.27±0.20 mm on quantitative coronary angiography, with an increase in neointima of 0.68±0.43 mm(2) on optical coherence tomography and 0.17±0.26 mm(2) on intravascular ultrasound. Struts still recognizable on optical coherence tomography at 2 years showed 99% of neointimal coverage with optical and ultrasonic signs of bioresorption accompanied by increase in mean scaffold area compared with baseline (0.54±1.09 mm(2) on intravascular ultrasound, P=0.003 and 0.77±1.33 m(2) on optical coherence tomography, P=0.016). Two-year major adverse cardiac event rate was 6.8% without any scaffold thrombosis. CONCLUSIONS: This serial analysis of the second generation of the everolimus-eluting bioresorbable vascular scaffold confirmed, at medium term, the safety and efficacy of the new device. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT00856856.


Assuntos
Implantes Absorvíveis , Angioplastia Coronária com Balão/instrumentação , Fármacos Cardiovasculares/administração & dosagem , Materiais Revestidos Biocompatíveis , Doença da Artéria Coronariana/terapia , Vasos Coronários , Diagnóstico por Imagem , Stents Farmacológicos , Sirolimo/análogos & derivados , Alicerces Teciduais , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Austrália , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/fisiopatologia , Reestenose Coronária/diagnóstico , Reestenose Coronária/etiologia , Trombose Coronária/diagnóstico , Trombose Coronária/etiologia , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/patologia , Vasos Coronários/fisiopatologia , Diagnóstico por Imagem/métodos , Europa (Continente) , Everolimo , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Neointima , Nova Zelândia , Valor Preditivo dos Testes , Desenho de Prótese , Fatores de Risco , Sirolimo/administração & dosagem , Fatores de Tempo , Tomografia de Coerência Óptica , Resultado do Tratamento , Ultrassonografia de Intervenção
6.
JACC Cardiovasc Interv ; 5(6): 656-65, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22721662

RESUMO

OBJECTIVES: This study sought to investigate in vivo the vascular response at the proximal and distal edges of the second-generation ABSORB everolimus-eluting bioresorbable vascular scaffold (BVS). BACKGROUND: The edge vascular response after implantation of the BVS has not been previously investigated. METHODS: The ABSORB Cohort B trial enrolled 101 patients and was divided into B(1) (n = 45) and B(2) (n = 56) subgroups. The adjacent (5-mm) proximal and distal vessel segments to the implanted ABSORB BVS were investigated at either 6 months (B(1)) or 1 year (B(2)) with virtual histology intravascular ultrasound (VH-IVUS) imaging. RESULTS: At the 5-mm proximal edge, the only significant change was modest constrictive remodeling at 6 months (Δ vessel cross-sectional area: -1.80% [-3.18; 1.30], p < 0.05), with a tendency to regress at 1 year (Δ vessel cross-sectional area: -1.53% [-7.74; 2.48], p = 0.06). The relative change of the fibrotic and fibrofatty (FF) tissue areas at this segment were not statistically significant at either time point. At the 5-mm distal edge, a significant increase in the FF tissue of 43.32% [-19.90; 244.28], (p < 0.05) 1-year post-implantation was evident. The changes in dense calcium need to be interpreted with caution since the polymeric struts are detected as "pseudo" dense calcium structures with the VH-IVUS imaging modality. CONCLUSIONS: The vascular response up to 1 year after implantation of the ABSORB BVS demonstrated some degree of proximal edge constrictive remodeling and distal edge increase in FF tissue resulting in nonsignificant plaque progression with adaptive expansive remodeling. This morphological and tissue composition behavior appears to not significantly differ from the behavior of metallic drug-eluting stents at the same observational time points.


Assuntos
Implantes Absorvíveis , Angioplastia Coronária com Balão/instrumentação , Fármacos Cardiovasculares/administração & dosagem , Doença da Artéria Coronariana/terapia , Vasos Coronários/diagnóstico por imagem , Stents Farmacológicos , Sirolimo/análogos & derivados , Alicerces Teciduais , Ultrassonografia de Intervenção , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Vasos Coronários/patologia , Everolimo , Feminino , Fibrose , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Desenho de Prótese , Sirolimo/administração & dosagem , Fatores de Tempo , Resultado do Tratamento , Calcificação Vascular/diagnóstico por imagem
8.
Eur Heart J ; 32(3): 294-304, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21123276

RESUMO

AIMS: The first generation of the everolimus-eluting bioresorbable vascular scaffold (BVS 1.0) showed an angiographic late loss higher than the metallic everolimus-eluting stent Xience V due to scaffold shrinkage. The new generation (BVS 1.1) presents a different design and manufacturing process than the BVS 1.0. This study sought to evaluate the differences in late shrinkage, neointimal response, and bioresorption process between these two scaffold generations using optical coherence tomography (OCT). METHODS AND RESULTS: A total of 12 lesions treated with the BVS 1.0 and 12 selected lesions treated with the revised BVS 1.1 were imaged at baseline and 6-month follow-up with OCT. Late shrinkage and neointimal area (NIA) were derived from OCT area measurements. Neointimal thickness was measured in each strut. Strut appearance has been classified as previously described. Baseline clinical, angiographic, and OCT characteristics were mainly similar in the two groups. At 6 months, absolute and relative shrinkages were significantly larger for the BVS 1.0 than for the BVS 1.1 (0.98 vs. 0.07 mm² and 13.0 vs. 1.0%, respectively; P = 0.01). Neointimal area was significantly higher in the BVS 1.0 than in the BVS 1.1 (in-scaffold area obstruction of 23.6 vs. 12.3%; P < 0.01). Neointimal thickness was also larger in the BVS 1.0 than in the BVS 1.1 (166.0 vs. 76.4 µm; P < 0.01). Consequently, OCT, intravascular ultrasound, and angiographic luminal losses were higher with the BVS 1.0 than with the BVS 1.1. At 6 months, strut appearance was preserved in only 2.9% of the BVS 1.0 struts, but remained unchanged with the BVS 1.1 indicating different state of strut microstucture and/or their reflectivity. CONCLUSION: The BVS 1.1 has less late shrinkage and less neointimal growth at 6-month follow-up compared with the BVS 1.0. A difference in polymer degradation leading to changes in microstructure and reflectivity is the most plausible explanation for this finding.


Assuntos
Stents Farmacológicos/normas , Imunossupressores/administração & dosagem , Isquemia Miocárdica/diagnóstico por imagem , Sirolimo/análogos & derivados , Tomografia de Coerência Óptica/métodos , Idoso , Materiais Biocompatíveis/normas , Prótese Vascular/normas , Angiografia Coronária/métodos , Everolimo , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/terapia , Desenho de Prótese , Falha de Prótese , Sirolimo/administração & dosagem , Alicerces Teciduais , Ultrassonografia de Intervenção
9.
JACC Cardiovasc Interv ; 3(8): 836-44, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20723856

RESUMO

OBJECTIVES: The purpose of this study is to assess jailing of side branches (SB) by the everolimus-eluting, bioresorbable vascular scaffold (BVS) with 3-dimensional (3D) optical coherence tomography (OCT) reconstruction. BACKGROUND: Because BVS struts at the SB orifice are suspected of being bioresorbed and/or forming a neointimal bridge, OCT has been used to evaluate the struts in detail at that particular site. Our understanding of the 3D relationship of the strut and the SB orifice is limited by the use of 2-dimensional OCT images. Fourier-domain OCT enables reliable 3D reconstruction of coronary vessels. METHODS: The ABSORB Cohort B (A Clinical Evaluation of the Bioabsorbable Everolimus Eluting Coronary Stent System in the Treatment of Patients With de Novo Native Coronary Artery Lesions) trial is a multicenter single-arm trial to assess the safety and performance of the BVS. Fourier-domain OCT pullbacks (C7-XR system, LightLab Imaging Inc., Westford, Massachusetts) are obtained at pullback speed of 20 mm/s and 3D renderings are performed. The orifices of the SB are assessed visually. The area of SB orifice and the number of strut-free compartments delineated by the BVS struts are evaluated. RESULTS: Fifty-one OCT pullbacks were acquired: 33 pullbacks were imaged with Fourier-domain OCT and 27 treated segments had 46 side branches. Three-dimensional assessment was feasible in 87% (40 of 46) of pullbacks. The mean area of the SB orifice was 1.16 +/- 1.02 mm(2). The mean number of strut-free compartments was 2.0 +/- 1.1. The classification of the overhanging struts is proposed. CONCLUSIONS: This study demonstrates that 3D OCT reconstruction is feasible to evaluate the orifices of SB jailed with BVS. (ABSORB Clinical Investigation, Cohort B; NCT00856856).


Assuntos
Angioplastia Coronária com Balão/instrumentação , Estenose Coronária/terapia , Stents Farmacológicos , Imageamento Tridimensional , Tomografia de Coerência Óptica , Adulto , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Austrália , Fármacos Cardiovasculares/administração & dosagem , Estenose Coronária/patologia , Europa (Continente) , Everolimo , Estudos de Viabilidade , Feminino , Análise de Fourier , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Nova Zelândia , Valor Preditivo dos Testes , Desenho de Prótese , Sirolimo/administração & dosagem , Sirolimo/análogos & derivados , Terminologia como Assunto , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA