Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Bases de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Nucl Med Commun ; 36(2): 168-79, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25369753

RESUMO

OBJECTIVES: Previously we have proposed a technique for the measurement of plasma clearance in patients with ascites. The impact of using the technique was assessed and the results compared with those from a reference technique in 111 patients having glomerular filtration rate measurements as part of their workup for liver transplantation. METHODS: Results of calculations using the new technique were compared with plasma clearance measurements obtained using a conventional slope-intercept technique and with clearance measurements based on urine collection. Discrepancies between the results of plasma clearance and urinary clearance assessments were investigated by using an uncollimated gamma camera to measure the total retention of the tracer. RESULTS: Conventional slope-intercept calculations overestimated clearance compared with the new technique by more than 20% in 21% of the patients. Significant differences between the results of the two methods were more likely in patients with more severe ascites. Results of urine collection-based measurements of Cr-51 EDTA clearance were frequently significantly lower than measurements using the new technique, whereas measurements of urinary clearance of creatinine were higher. Gamma camera measurements suggest that discrepancies between total and urinary clearance of Cr-51 EDTA are due to incomplete urine collection. CONCLUSION: The new technique is a practical method for assessment of kidney function and should be used in patients with liver disease who have or may have ascites.


Assuntos
Taxa de Filtração Glomerular , Testes de Função Renal/métodos , Hepatopatias/diagnóstico por imagem , Radioisótopos de Cromo/sangue , Radioisótopos de Cromo/urina , Ácido Edético/sangue , Ácido Edético/urina , Humanos , Hepatopatias/sangue , Hepatopatias/terapia , Hepatopatias/urina , Transplante de Fígado , Cintilografia , Fatores de Tempo
3.
Nucl Med Commun ; 34(11): 1124-32, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23995396

RESUMO

AIM: The aim of this study was to identify a practical sampling regimen and calculation method that could be used to measure the glomerular filtration rate in patients with ascites using plasma sampling. PATIENTS AND METHODS: Thirteen potential liver transplant patients with cirrhosis and ascites were injected with Cr-51 ethylenediaminetetraacetic acid, and plasma samples were obtained at up to 16 time points for each patient. Reference clearance values were calculated using the area under the plasma clearance curve, which was calculated using all the available data points. Clearance calculations were then performed using three and four data points from each patient and three different calculation methods to identify a sampling regimen and calculation method that yielded good agreement with the reference values. RESULTS: The reference clearances ranged from 6 to 80 ml/min. Sampling at 2, 4, 8 and 24 h and calculation of the area under the plasma clearance curve using a log-linear trapezoidal rule with extrapolation to zero and infinity yielded a relative root mean square difference from the reference of less than 7%. CONCLUSION: This method for measuring glomerular filtration rate in patients with cirrhosis and ascites was found to be more accurate than the slope-intercept technique and is a practical alternative to urine collection.


Assuntos
Algoritmos , Ascite/metabolismo , Análise Química do Sangue/métodos , Ácido Edético/farmacocinética , Taxa de Filtração Glomerular , Cirrose Hepática/metabolismo , Área Sob a Curva , Ascite/sangue , Radioisótopos de Cromo/farmacocinética , Humanos , Cirrose Hepática/sangue , Taxa de Depuração Metabólica , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA