RESUMO
BACKGROUND: The incidence of abdominal aortic aneurysms (AAAs) has increased during the last decades. However, there is still controversy about the management of medium-sized AAAs. Therefore, novel biomarkers, besides aneurysmal diameter, are needed to assess aortic wall integrity and risk of rupture. Elastin is the key protein for maintaining aortic wall tensile strength and stability. The progressive breakdown of structural proteins, in particular, medial elastin, is responsible for the inability of the aortic wall to withstand intraluminal hemodynamic forces. Here, we evaluate the usefulness of elastin-specific molecular MRI for the in vivo characterization of AAAs. METHODS AND RESULTS: To induce AAAs, ApoE(-/-) mice were infused with angiotensin-II. An elastin-specific magnetic resonance molecular imaging agent (ESMA) was administered after 1, 2, 3, and 4 weeks of angiotensin-II infusion to assess elastin composition of the aorta (n=8 per group). The high signal provided by ESMA allowed for imaging with high spatial resolution, resulting in an accurate assessment of ruptured elastic laminae and the compensatory expression of elastic fibers. In vivo contrast-to-noise ratios and R1-relaxation rates after ESMA administration were in good agreement with ex vivo histomorphometry (Elastica van Gieson stain) and gadolinium concentrations determined by inductively coupled plasma mass spectroscopy. Electron microscopy confirmed colocalization of ESMA with elastic fibers. CONCLUSIONS: Changes in elastin content could be readily delineated and quantified at different stages of AAAs by elastin-specific molecular magnetic resonance imaging. ESMA-MRI offers potential for the noninvasive detection of the aortic rupture site prior to dilation of the aorta and the subsequent in vivo monitoring of compensatory repair processes during the progression of AAAs.
Assuntos
Aorta Abdominal/química , Aneurisma da Aorta Abdominal/diagnóstico , Elastina/análise , Imageamento por Ressonância Magnética/métodos , Imagem Molecular/métodos , Animais , Aorta Abdominal/fisiopatologia , Aorta Abdominal/ultraestrutura , Aneurisma da Aorta Abdominal/metabolismo , Aneurisma da Aorta Abdominal/fisiopatologia , Modelos Animais de Doenças , Elasticidade , Masculino , Espectrometria de Massas , Camundongos , Camundongos Endogâmicos C57BL , Microscopia EletrônicaRESUMO
BACKGROUND: Cardiovascular magnetic resonance (CMR) is the current gold standard for the assessment of left ventricular (LV) function. Repeated breath-holds are needed for standard multi-slice 2D cine steady-state free precession sequences (M2D-SSFP). Accelerated single breath-hold techniques suffer from low contrast between blood pool and myocardium. In this study an intravascular contrast agent was prospectively compared to an extravascular contrast agent for the assessment of LV function using a single-breath-hold 3D-whole-heart cine SSFP sequence (3D-SSFP). METHODS: LV function was assessed in fourteen patients on a 1.5 T MR-scanner (Philips Healthcare) using 32-channel coil technology. Patients were investigated twice using a 3D-SSFP sequence (acquisition time 18-25 s) after Gadopentetate dimeglumine (GdD, day 1) and Gadofosveset trisodium (GdT, day 2) administration. Image acquisition was accelerated using sensitivity encoding in both phase encoding directions (4xSENSE). CNR and BMC were both measured between blood and myocardium. The CNR incorporated noise measurements, while the BMC represented the coeffiancy between the signal from blood and myocardium [1]. Contrast to noise ratio (CNR), blood to myocardium contrast (BMC), image quality, LV functional parameters and intra-/interobserver variability were compared. A M2D-SSFP sequence was used as a reference standard on both days. RESULTS: All 3D-SSFP sequences were successfully acquired within one breath-hold after GdD and GdT administration. CNR and BMC were significantly (p < 0.05) higher using GdT compared to GdD, resulting in an improved endocardial definition. Using 3D-SSFP with GdT, Bland-Altman plots showed a smaller bias (95% confidence interval LVEF: 9.0 vs. 23.7) and regression analysis showed a stronger correlation to the reference standard (R2 = 0.92 vs. R2 = 0.71), compared to 3D-SSFP with GdD. CONCLUSIONS: A single-breath-hold 3D-whole-heart cine SSFP sequence in combination with 32-channel technology and an intravascular contrast agent allows for the accurate and fast assessment of LV function.
Assuntos
Meios de Contraste/administração & dosagem , Vasos Coronários/patologia , Cardiopatias Congênitas/diagnóstico , Imageamento Tridimensional , Imagem Cinética por Ressonância Magnética/métodos , Pericárdio/patologia , Função Ventricular Esquerda/fisiologia , Adulto , Suspensão da Respiração , Feminino , Seguimentos , Gadolínio DTPA/administração & dosagem , Cardiopatias Congênitas/fisiopatologia , Ventrículos do Coração/patologia , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Estudos Prospectivos , Respiração , Adulto JovemRESUMO
OBJECTIVE: Molecular magnetic resonance imaging (MRI) has emerged as a promising non-invasive modality to characterize atherosclerotic vessel wall changes on a morphological and molecular level. Intraplaque and endothelial fibrin has recently been recognized to play an important role in the progression of atherosclerosis. This study aimed to investigate the feasibility of intraplaque and endothelial fibrin detection using a fibrin-targeted contrast-agent, FTCA (EPIX Pharmaceuticals, Lexington, MA), in a mouse model of atherosclerosis. METHODS: Male apolipoproteinE-knockout mice (ApoE(-/-)) were fed a high fat diet (HFD) for one to three months. MRI of the brachiocephalic artery was performed prior to and 90 min after the administration of FTCA (n=8 per group). Contrast to noise ratios (CNR) and longitudinal relaxation rates (R1) of plaques were determined and compared to ex vivo fibrin density measurements on immunohistological sections stained with a fibrin-specific antibody and gadolinium concentrations measured by inductively coupled mass spectroscopy (ICP-MS). RESULTS: Molecular MRI after FTCA administration demonstrated a significant increase (p<0.05) in contrast agent uptake in brachiocephalic artery plaques. In vivo CNR measurements were in good agreement with ex vivo fibrin density measurements on immunohistochemistry (y=2.4x+11.3, R(2)=0.82) and ICP-MS (y=0.95x+7.1, R(2)=0.70). Late stage atherosclerotic plaques displayed the strongest increase in CNR, R1, ex vivo fibrin staining and gadolinium concentration (p<0.05). CONCLUSION: This study demonstrated the feasibility of intraplaque and endothelial fibrin imaging using FTCA. Direct in vivo fibrin detection and quantification could be useful for characterization and staging of coronary and carotid atherosclerotic lesions, which may aid diagnosis and intervention.
Assuntos
Apolipoproteínas E/deficiência , Aterosclerose/diagnóstico , Meios de Contraste , Endotélio Vascular/química , Fibrina/análise , Gadolínio , Peptídeos , Placa Aterosclerótica/química , Animais , Aterosclerose/patologia , Dieta Hiperlipídica , Modelos Animais de Doenças , Imageamento por Ressonância Magnética/métodos , Masculino , CamundongosRESUMO
BACKGROUND: Macrophages have been identified as a major contributor to plaque development and destabilization in atherosclerosis. The aim of this study was to noninvasively assess uptake of citrate coated very small iron oxide particles at different stages of plaque development in the brachiocephalic artery of apoE(-/-) mice. Susceptibility gradient mapping (SGM) was applied to generate positive contrast images and to quantify iron oxide uptake. METHODS AND RESULTS: ApoE(-/-) mice were fed a high-fat diet for 4, 8, or 12 weeks; 300 µmol Fe/kg was injected 24 and 48 hours before final MRI. Increasing very small iron oxide particle uptake was observed over the course of atherosclerotic plaque development. Simultaneous administration of pravastatin led to a significant decrease in very small iron oxide particle uptake, assessed by mass spectroscopy and histology. SGM-MRI allowed the generation of positive contrast images, and magnitudes (mT/m) of contrast enhancement in SG parameter maps significantly correlated with the absolute iron oxide content (R(2)=0.70, P<0.05) and the macrophage density (R(2)=0.71, P<0.05). CONCLUSIONS: This study shows an increase in iron oxide uptake (measured by in vivo SGM-MRI, histology, and mass spectroscopy) with the progression of plaque development in an apoE(-/-) mouse model of accelerated atherosclerosis. Positive contrast provided by SGM-MRI allowed for a clear visualization of intraplaque iron oxide depositions, and magnitudes (mT/m) of contrast enhancement in SG parameter maps allowed for the quantification of intraplaque iron oxide particles.
Assuntos
Meios de Contraste , Compostos Férricos , Imageamento por Ressonância Magnética , Placa Aterosclerótica/patologia , Animais , Apolipoproteínas E/genética , Western Blotting , Tronco Braquiocefálico/patologia , Progressão da Doença , Galectina 3 , Processamento de Imagem Assistida por Computador , Macrófagos/patologia , Masculino , Espectrometria de Massas , Camundongos , Camundongos Knockout , Placa Aterosclerótica/diagnósticoRESUMO
Atherosclerosis and its consequences remain the main cause of mortality in industrialized and developing nations. Plaque burden and progression have been shown to be independent predictors for future cardiac events by intravascular ultrasound. Routine prospective imaging is hampered by the invasive nature of intravascular ultrasound. A noninvasive technique would therefore be more suitable for screening of atherosclerosis in large populations. Here we introduce an elastin-specific magnetic resonance contrast agent (ESMA) for noninvasive quantification of plaque burden in a mouse model of atherosclerosis. The strong signal provided by ESMA allows for imaging with high spatial resolution, resulting in accurate assessment of plaque burden. Additionally, plaque characterization by quantifying intraplaque elastin content using signal intensity measurements is possible. Changes in elastin content and the high abundance of elastin during plaque development, in combination with the imaging properties of ESMA, provide potential for noninvasive assessment of plaque burden by molecular magnetic resonance imaging (MRI).