Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Sensors (Basel) ; 21(14)2021 Jul 07.
Artigo em Inglês | MEDLINE | ID: mdl-34300410

RESUMO

The aim of this study was to quantitatively assess the residual adhesive on orthodontic ceramic bracket-removed dental surface. In orthodontic process, ceramic bracket was repeated debonding physically, then the adhesive remained on the dental surface. The residual adhesive caused a lack of adhesive strength between dental and ceramic bracket. Since commonly used adhesive in orthodontics is translucent, residual adhesive is hard to be detected with conventional microscopes. Therefore, 1310 nm center wavelength swept-source OCT system based on laboratory customized image processing algorithm was used for the precise detection of residual adhesive on tooth surface. The algorithm separates residual adhesive from dental surface by comparing the height of adjacent B-scan images, while providing color-scaled images emphasizing the thickness information of residual adhesive. Finally, the acquired results were compared with microscopic and adhesive remnant index scoring gold standards, while the comparison confirmed the potential merits and the improvements of the proposed method over gold standards.


Assuntos
Adesivos , Braquetes Ortodônticos , Algoritmos , Cerâmica , Teste de Materiais , Propriedades de Superfície , Tomografia de Coerência Óptica
2.
Sci Rep ; 11(1): 666, 2021 01 12.
Artigo em Inglês | MEDLINE | ID: mdl-33436674

RESUMO

Nail beautification is a widely applied gender independent practice. Excessive nail beautifications and nail-arts have a direct impact on the nail structure and can cause nail disorders. Therefore, the assessment of post-progressive nail-art effects on the nail is essential to maintain optimal nail health and to avoid any undesirable disorders. In this study, in vivo nails were examined in control stage, with a nail-art stage, and after removing the nail-art stage using a 1310 nm spectral-domain optical coherence tomography (SD-OCT) system. The acquired cross-sectional OCT images were analyzed by a laboratory customized signal processing algorithm to obtain scattered intensity profiling assessments that could reveal the effects of nail beautification on the nail plate. The formation and progression of cracks on the nail plate surface were detected as an effect of nail beautification after 72 h of nail-art removal. Changes in backscattered light intensity and nail plate thickness of control and art-removed nails were quantitatively compared. The results revealed the potential feasibility of the developed OCT-based inspection procedure to diagnose post-progressive nail-art effects on in vivo nail plate, which can be helpful to prevent nail plate damages during art removal through real-time monitoring of the boundary between the nail plate and nail-art. Besides nail-art effects, the developed method can also be used for the investigation of nail plate abnormalities by examining the inconsistency of internal and external nail plate structure, which can be diagnosed with both qualitative and quantitative assessments from a clinical perspective.


Assuntos
Doenças da Unha/diagnóstico , Unhas/fisiopatologia , Tomografia de Coerência Óptica/métodos , Adulto , Estudos Transversais , Feminino , Humanos , Doenças da Unha/diagnóstico por imagem , Unhas/diagnóstico por imagem
3.
Ann Biomed Eng ; 48(12): 3014-3023, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33118064

RESUMO

A bacterium in bacterial colony is a basal component of bacterial studies and is therefore of considerable importance. The morphological characteristics of a single colony have been widely used as the standard to identify diverse bacterial species. However, the conventional methods for obtaining morphological information, such as microscopic techniques, cannot provide tomographic views. This study utilizes spectral-domain optical coherence tomography (SD-OCT) to observe both external and internal structures for single colonies. OCT imaging provided a clear top (projection) and lateral (cross-sectional) images, which can identify distinct features in the fifteen different bacterial species examined. Through the acquired OCT images, the elevation type in each genus was confirmed, and the quantitative measurements for morphology including a diameter, height, and elevation angle were achieved. Moreover, the OCT raw data was used to build three-dimensional images to observe outer appearances in all direction. As a result, the averaged angles of 7.92°, 14.40°, 6.78°, and 11.92° of the genus Hymenobacter, Spirosoma, Bacillus, and Deinococcus, respectively, were calculated. In conclusion, we have demonstrated that OCT is a highly feasible, non-invasive method for the identification of bacterial species, providing detailed morphological and visual information. It thus has strong potential for applications in bacteriology, as well as biomedical and food sciences.


Assuntos
Bactérias/citologia , Técnicas Bacteriológicas , Tomografia de Coerência Óptica
4.
J Biophotonics ; 13(2): e201900202, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31670908

RESUMO

An elevated relative moisture in the external ear canal and middle ear cavity may predispose to chronic otorrhea and related infections along with abnormal tympanic membrane (TM) vibration patterns. Therefore, phase shift-resolved optical Doppler vibrography (ODV) was used for vibration assessments of moisture influenced cadaveric TM. ODV was applied to generate time resolved cross-sectional and volumetric vibrographs of a cadaveric TM, driven acoustically at several frequencies. In order to analyze the effect of moisture on TM, homogenous moisture conditions were provided by soaking the cadaveric TM specimens in 1× phosphate buffer saline with a pH of 7.4. The TM specimen was exposed to a rapidly switchable frequency generator during the ODV image acquisition. The experiment was conducted for 3 hours and the cadaveric TM was exposed to each frequency with an interval of 30 minutes. Acquired phase shift-resolved ODV assessments revealed a depth dependent vibration tendency between the applied frequencies, along with a decline in the moisture level of the cadaveric TM specimen. Thus, the ODV method can aid our understanding of sound conduction in the middle ear, thus supporting the diagnosis of TM diseases.


Assuntos
Orelha Média , Membrana Timpânica , Cadáver , Estudos Transversais , Orelha Média/diagnóstico por imagem , Humanos , Membrana Timpânica/diagnóstico por imagem , Vibração
5.
Sci Rep ; 8(1): 17432, 2018 11 27.
Artigo em Inglês | MEDLINE | ID: mdl-30479360

RESUMO

Significant technical and optical advances are required for intraoperative optical coherence tomography (OCT) to be utilized during otological surgeries. Integrating OCT with surgical microscopy makes it possible to evaluate soft tissue in real-time and at a high resolution. Herein, we describe an augmented-reality, intraoperative OCT/microscope system with an extended working distance of 280 mm, providing more space for surgical manipulation than conventional techniques. We initially performed ex vivo experiments to evaluate system performance. In addition, we validated the system by performing preliminary clinical assessments of tympanomastoidectomy outcomes in six patients with chronic otitis media. The system evaluated residual inflammation in the region-of-interest of the mastoid bone. Most importantly, the system intraoperatively revealed the connection between the graft and the remnant tympanic membrane. The extended working distance allows otological surgeons to evaluate the status of both the mastoid bone and tympanic membrane during manipulation, affording full intraoperative imaging.


Assuntos
Mastoidectomia/métodos , Microcirurgia/métodos , Monitorização Intraoperatória/métodos , Otite/cirurgia , Tomografia de Coerência Óptica/métodos , Timpanoplastia/métodos , Animais , Cobaias , Humanos , Masculino , Processo Mastoide/cirurgia , Mastoidectomia/instrumentação , Microcirurgia/instrumentação , Monitorização Intraoperatória/instrumentação , Tomografia de Coerência Óptica/instrumentação , Membrana Timpânica/cirurgia , Timpanoplastia/instrumentação
6.
Appl Opt ; 56(11): 3023, 2017 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-28414359

RESUMO

This note points out additional funding that was not added to Appl. Opt.56, D108 (2017)APOPAI0003-693510.1364/AO.56.00D108.

7.
Appl Opt ; 56(9): D108-D114, 2017 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-28375377

RESUMO

We developed a compact, wearable diagnostic imaging modality employing optical coherence tomography for in situ plant leaf quality assessments. This system is capable of diagnosing infected leaves at the initial disease stages. Our system is a versatile backpack-type imaging modality with a compact spectrometer, miniature computer, rechargeable power source, and handheld inspection probe. This method enhances real-time in situ specimen inspection through direct implementation of the imaging modality in a plantation. To evaluate the initial performance, field experiments were conducted in apple, pear, and persimmon plantations. Based on the obtained results, we can conclude that the developed imaging modality can be considered as a promising, efficient, convenient, and fast in situ inspection technique for various agricultural fields, which minimizes the limitations of complex tabletop inspection modalities.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA