Ann Cardiothorac Surg ; 10(1): 141-148, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33575184

RESUMO

BACKGROUND: Reductive annuloplasty repair of ischemic mitral regurgitation (IMR) is associated with high rates of recurrent MR, which may be improved with etiology-specific annuloplasty rings. METHODS: From October 2005 to May 2015, 128 consecutive patients underwent repair of IMR with the GeoForm ring. Clinical data was extracted from our local Society of Thoracic Surgeons database and electronic medical records. Mortality data was obtained from the Michigan State Social Security Death Index. RESULTS: The average age of patients was 65±11 years with mean pre-op left ventricular ejection fraction (LVEF) of 30%±10% and MR grade of 3.1±0.9 (0-4+). Thirty-day mortality was 4.7%, rate of renal failure 7.9%, rate of atrial fibrillation 27.3%, and no strokes were observed. Of the surviving patients, 89% (109/122) had a follow-up echocardiogram beyond 1 month with a mean echocardiographic follow-up of 59±39 months. LVEF improved from 30%±10% to 38%±14%, P<0.001) while end-diastolic (5.9±0.0 to 5.3±0.9 cm, P<0.001) and end-systolic (5.0±1.0 to 4.4±1.1 cm, P<0.001) left ventricular (LV) diameters decreased, as compared to pre-operative values. Seven patients were found to have recurrent moderate or greater IMR in follow-up to 10 years with three being due to ring dehiscence. One-, 5-, and 10-year freedom from recurrent moderate or severe IMR was 98%, 94%, and 80% respectively. One-, 5-, and 10-year survival was 91%, 77%, and 44%, respectively. CONCLUSIONS: Overall, etiology-specific ring repair of IMR was associated with low rates of recurrent MR on long-term follow-up, coupled with significant LV reverse remodeling and improvement in ejection fraction.

2.
J Thorac Cardiovasc Surg ; 160(6): 1479-1485.e5, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31706553

RESUMO

BACKGROUND: Del Nido cardioplegia (DC) offers prolonged single-dose myocardial protection in pediatric cardiac surgery. We set out to evaluate the efficacy of DC in adult patients undergoing isolated coronary artery bypass grafting (CABG). METHODS: From January 2012 to October 2017, 851 consecutive isolated CABG surgeries were performed by 2 study surgeons at our center with blood cardioplegia (BC, n = 350), used from January 2012 to April 2014, and DC (n = 501), used from May 2014 to October 2017. Propensity matching was used to yield 325 well-matched pairs. Clinical data were extracted from our local Society of Thoracic Surgeons database and mortality data from the Michigan State Social Security Death Index. RESULTS: Single-dose administration was used in 83% (417/501) of patients receiving DC. In propensity-matched groups, postoperative median troponin T levels (0.28 [0.16-0.59] ng/mL vs 0.46 [0.27-0.81] ng/mL; P < .01) were lower for patients receiving DC, and no difference in ejection fraction on postoperative echocardiography was observed (54 ± 12% and 53 ± 13% for BC and DC, respectively; P = .36). Perioperative outcomes were similar except for greater rate of atrial fibrillation (33% vs 23%; P = .01) in the DC group. Subgroup analyses revealed equivalent myocardial protection and clinical outcomes in patients with age ≥75 years, left ventricular ejection fraction ≤35%, left main disease, or Society of Thoracic Surgeons score ≥2.5%. Four-year survival did not differ between patients undergoing BC or DC. CONCLUSIONS: The current study revealed noninferior myocardial protection and clinical outcomes with DC versus BC in both routine and greater-risk patients undergoing isolated CABG. DC demonstrated the feasibility of single-dose administration for isolated CABG surgery. Larger randomized studies are needed to further explore the safety and efficacy of DC in adult cardiac surgery with longer crossclamp times.


Assuntos
Ponte de Artéria Coronária/métodos , Doença da Artéria Coronariana/cirurgia , Parada Cardíaca Induzida/métodos , Complicações Pós-Operatórias/prevenção & controle , Idoso , Soluções Cardioplégicas/administração & dosagem , Doença da Artéria Coronariana/diagnóstico , Relação Dose-Resposta a Droga , Feminino , Seguimentos , Humanos , Masculino , Complicações Pós-Operatórias/mortalidade , Estudos Retrospectivos , Taxa de Sobrevida/tendências , Resultado do Tratamento , Estados Unidos/epidemiologia
3.
Ann Thorac Surg ; 106(1): 58-62, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29501643

RESUMO

BACKGROUND: Minimally invasive aortic valve replacement (mAVR) is gaining clinical acceptance; however, it is associated with increased operative times because of the limited surgical field and access. The Cor-Knot (CK; LSI Solutions, Victor, NY) is an automated fastening device designed to facilitate suture fastening, but clinical data in mAVR are lacking. METHODS: From May 2014 to February 2017, 92 patients underwent mAVR at Spectrum Health in Grand Rapids, Michigan; 39 valves were secured with manually tied sutures, and 53 valves were entirely secured with the CK device. Preoperative characteristics and 30-day outcomes data were extracted from the local The Society of Thoracic Surgeons database and the patients' electronic medical records. Survival data were obtained from the Michigan State Social Security Death Index. RESULTS: No significant differences in preoperative characteristics were noted between the two groups. Aortic cross-clamp time (72 ± 12 minutes vs 82 ± 15 minutes; p = 0.001) was significantly shorter with CK. There was no difference in the rate of postoperative mortality (0% vs 0%), stroke (0% vs 1.9%), atrial fibrillation (28% vs 33%), renal failure (0% vs 3.8%), or pacemaker implantation (5.1% vs 5.7%) between patients with manually tied sutures and patients with sutures fastened with the CK. Valve function on postoperative echocardiography and 1-year patient survival rates were similar. CONCLUSIONS: In mAVR, the CK device was associated with reduced aortic cross-clamp time while providing equivalent clinical outcomes. Larger studies are needed to confirm the efficacy, safety, and cost-effectiveness of the CK device in minimally invasive aortic valve surgery.


Assuntos
Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Automação/instrumentação , Implante de Prótese de Valva Cardíaca/métodos , Próteses Valvulares Cardíacas , Técnicas de Sutura/instrumentação , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/mortalidade , Estudos de Coortes , Ecocardiografia Doppler/métodos , Feminino , Seguimentos , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Estimativa de Kaplan-Meier , Masculino , Michigan , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Procedimentos Cirúrgicos Minimamente Invasivos/mortalidade , Estudos Retrospectivos , Medição de Risco , Volume Sistólico/fisiologia , Análise de Sobrevida , Fatores de Tempo , Resultado do Tratamento
4.
Ann Thorac Surg ; 99(2): 518-23, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25195546

RESUMO

BACKGROUND: Transcatheter aortic valve implantation (TAVI) has been advocated for very elderly patients with aortic stenosis, and prior cardiac surgery as a less invasive treatment option. Although surgical aortic valve replacement (AVR) is safe and effective in selected elderly patients, the perioperative and mid-term outcomes of AVR in very elderly with prior cardiac surgery are unknown. METHODS: The Society of Thoracic Surgeons (STS) Database at our center enrolled 3,735 patients after AVR since 1997. In this time interval, we identified 61 patients 80 years and older who underwent AVR for severe AS or failed aortic bioprosthesis after having prior cardiac surgery. All clinical parameters were derived from the STS database. Follow-up mortality was assessed using the Social Security Death Index. RESULTS: The average age of the patients was 83 ± 2 years, 77% were male, and 75% underwent an isolated coronary artery bypass graft (CABG) as their first cardiac procedure. The mean ejection fraction was 0.53 ± 0.13. The CABG was performed concurrently in 49% of patients at the time of redo sternotomy and AVR. Stented bioprosthesis was implanted in 61% of patients and stentless in 39%. Perioperative mortality was 1.6% (1 of 61). One, 3, 5, and 7 year survival rates were 85%, 69%, 63%, and 43%, respectively. Patients with AVR only had similar survival to patients who underwent concomitant AVR and CABG. Type of aortic prosthesis did not influence postoperative survival. CONCLUSIONS: In selected patients over the age of 80 with history of prior cardiac surgery, AVR can be performed safely with very good mid-term outcomes. Age alone should not be exclusion criteria for surgical AVR in octogenarians with prior cardiac surgery.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Ponte de Artéria Coronária , Implante de Prótese de Valva Cardíaca , Fatores Etários , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Estudos Retrospectivos , Fatores de Tempo
5.
J Thorac Cardiovasc Surg ; 148(5): 1951-6, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24685379

RESUMO

BACKGROUND: Reductive ring annuloplasty represents the current standard surgical therapy for ischemic mitral regurgitation (IMR); however, the clinical results have been suboptimal. Etiology-specific prostheses such as the GeoForm annuloplasty ring have been designed to better address the annular and subvalvular perturbations associated with IMR. However, clinical experience is limited, and mid-term results are lacking. METHODS: We reviewed the clinical outcomes of 86 patients who had undergone implantation of a GeoForm ring at our center from 2005 to 2011. Perioperative mortality and clinical parameters were derived from The Society of Thoracic Surgeons database. Follow-up survival was assessed using the Social Security Death Index. Surviving patients were interviewed by telephone for valve-specific follow-up data and to complete the Medical Outcomes Study, short-form, 36-item, quality-of-life questionnaire. RESULTS: The mean grade of IMR preoperatively was 3.1±0.8 (range, 1-4+), 0.2±0.4 in the immediate postoperative period, and 0.7±0.7 at the last mean follow-up point of 41 months; only 2 patients developed ≥2+IMR during the follow-up period, for a 5-year freedom from recurrent 2+ IMR of 86%. The mean left ventricular end-diastolic and end-systolic diameters decreased from before to after surgery from 6.0±0.0 cm to 5.3±09 cm and 5.0±0.9 cm to 4.3±1.1 cm, respectively (P<.001). Perioperative mortality was 5.8% (5 of 86), and 1-, 3-, and 5-year survival was 87%, 81%, and 75%, respectively. At the last follow-up point, 80% of patients were in New York Heart Association class I and II, and their quality of life was equal to, or better than, age-matched controls from the general population. CONCLUSIONS: Implantation of the GeoForm ring offers very good control of IMR, with low rate of recurrent IMR at mid-term follow-up. The use of this prosthesis was associated with good perioperative mortality, mid-term survival, and quality of life.


Assuntos
Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Anuloplastia da Valva Mitral , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Isquemia Miocárdica/complicações , Idoso , Intervalo Livre de Doença , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/mortalidade , Mortalidade Hospitalar , Humanos , Masculino , Michigan , Pessoa de Meia-Idade , Valva Mitral/fisiopatologia , Anuloplastia da Valva Mitral/efeitos adversos , Anuloplastia da Valva Mitral/mortalidade , Insuficiência da Valva Mitral/diagnóstico , Insuficiência da Valva Mitral/etiologia , Insuficiência da Valva Mitral/mortalidade , Insuficiência da Valva Mitral/fisiopatologia , Isquemia Miocárdica/mortalidade , Complicações Pós-Operatórias/mortalidade , Desenho de Prótese , Qualidade de Vida , Recidiva , Estudos Retrospectivos , Fatores de Risco , Índice de Gravidade de Doença , Inquéritos e Questionários , Fatores de Tempo , Resultado do Tratamento