Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
JACC Cardiovasc Imaging ; 16(12): 1552-1564, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37318394

RESUMO

BACKGROUND: Substantial variation in Agatston scores (AS) acquired with different computed tomography (CT) scanners may influence patient risk classification. OBJECTIVES: This study sought to develop a calibration tool for state-of-the-art CT systems resulting in vendor-neutral AS (vnAS), and to assess the impact of vnAS on coronary heart disease (CHD) event prediction. METHODS: The vnAS calibration tool was derived by imaging 2 anthropomorphic calcium containing phantoms on 7 different CT and 1 electron beam tomography system, which was used as the reference system. The effect of vnAS on CHD event prediction was analyzed with data from 3,181 participants from MESA (Multi-Ethnic Study on Atherosclerosis). Chi-square analysis was used to compare CHD event rates between low (vnAS <100) and high calcium groups (vnAS ≥100). Multivariable Cox proportional hazard regression models were used to assess the incremental value of vnAS. RESULTS: For all CT systems, a strong correlation with electron beam tomography-AS was found (R2 >0.932). Of the MESA participants originally in the low calcium group (n = 781), 85 (11%) participants were reclassified to a higher risk category based on the recalculated vnAS. For reclassified participants, the CHD event rate of 15% was significantly higher compared with participants in the low calcium group (7%; P = 0.008) with a CHD HR of 3.39 (95% CI: 1.82-6.35; P = 0.001). CONCLUSIONS: The authors developed a calibration tool that enables calculation of a vnAS. MESA participants who were reclassified to a higher calcium category by means of the vnAS experienced more CHD events, indicating improved risk categorization.


Assuntos
Aterosclerose , Doença da Artéria Coronariana , Calcificação Vascular , Humanos , Doença da Artéria Coronariana/diagnóstico por imagem , Cálcio , Valor Preditivo dos Testes , Tomografia Computadorizada por Raios X , Fatores de Risco , Medição de Risco , Vasos Coronários/diagnóstico por imagem , Calcificação Vascular/diagnóstico por imagem
2.
Abdom Radiol (NY) ; 46(5): 1931-1940, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33211150

RESUMO

PURPOSE: To determine whether multiphasic dual-energy (DE) CT iodine quantitation correlates with the severity of chronic liver disease. METHODS: We retrospectively included 40 cirrhotic and 28 non-cirrhotic patients who underwent a multiphasic liver protocol DECT. All three phases (arterial, portal venous (PVP), and equilibrium) were performed in DE mode. Iodine (I) values (mg I/ml) were obtained by placing regions of interest in the liver, aorta, common hepatic artery, and portal vein (PV). Iodine slopes (λ) were calculated as follows: (Iequilibrium-Iarterial)/time and (Iequilibrium-IPVP)/time. Spearman correlations between λ and MELD scores were evaluated, and the area under the curve of the receiver operating characteristic (AUROC) was calculated to distinguish cirrhotic and non-cirrhotic patients. RESULTS: Cirrhotic and non-cirrhotic patients had significantly different λequilibrium-arterial [IQR] for the caudate (λ = 2.08 [1.39-2.98] vs 1.46 [0.76-1.93], P = 0.007), left (λ = 2.05 [1.50-2.76] vs 1.51 [0.59-1.90], P = 0.002) and right lobes (λ = 1.72 [1.12-2.50] vs 1.13 [0.41-0.43], P = 0.003) and for the PV (λ = 3.15 [2.20-5.00] vs 2.29 [0.85-2.71], P = 0.001). λequilibrium-PVP were significantly different for the right (λ = 0.11 [- 0.45-1.03] vs - 0.44 [- 0.83-0.12], P = 0.045) and left lobe (λ = 0.30 [- 0.25-0.98] vs - 0.10 [- 0.35-0.24], P = 0.001). Significant positive correlations were found between MELD scores and λequilibrium-arterial for the caudate lobe (ρ = 0.34, P = 0.004) and λequilibrium-PVP for the caudate (ρ = 0.26, P = 0.028) and right lobe (ρ = 0.33, P = 0.007). AUROC in distinguishing cirrhotic and non-cirrhotic patients were 0.72 (P = 0.002), 0.71 (P = 0.003), and 0.75 (P = 0.001) using λequilibrium-arterial for the left lobe, right lobe, and PV, respectively. The λequilibrium-PVP AUROC of the right lobe was 0.73 (P = 0.001). CONCLUSION: Multiphasic DECT iodine quantitation over time is significantly different between cirrhotic and non-cirrhotic patients, correlates with the MELD score, and it could potentially serve as a non-invasive measure of cirrhosis and disease severity with acceptable diagnostic accuracy.


Assuntos
Doença Hepática Terminal , Iodo , Meios de Contraste , Humanos , Fígado/patologia , Cirrose Hepática/diagnóstico por imagem , Cirrose Hepática/patologia , Estudos Retrospectivos , Índice de Gravidade de Doença , Tomografia Computadorizada por Raios X
3.
Radiol Cardiothorac Imaging ; 1(5): e190067, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33778530

RESUMO

PURPOSE: To investigate the association of aortomitral continuity calcification (AMCC) with all-cause mortality, postprocedural paravalvular leak (PVL), and prolonged hospital stay in patients undergoing transcatheter aortic valve replacement (TAVR). MATERIALS AND METHODS: The authors retrospectively evaluated 329 patients who underwent TAVR between March 2013 and March 2016. AMCC, aortic valve calcification (AVC), and coronary artery calcification (CAC) were quantified by using preprocedural CT. Pre-procedural Society of Thoracic Surgeons (STS) score was recorded. Associations between baseline AMCC, AVC, and CAC and 1-year mortality, PVL, and hospital stay longer than 7 days were analyzed. RESULTS: The median follow-up was 415 days (interquartiles, 344-727 days). After 1 year, 46 of the 329 patients (14%) died and 52 (16%) were hospitalized for more than 7 days. Of the 326 patients who underwent postprocedural echocardiography, 147 (45%) had postprocedural PVL. The CAC score (hazard ratio: 1.11 per 500 points) and AMCC mass (hazard ratio: 1.13 per 500 mg) were associated with 1-year mortality. AVC mass (odds ratio: 1.93 per 100 mg) was associated with postprocedural PVL. Only the STS score was associated with prolonged hospital stay (odds ratio: 1.19 per point). CONCLUSION: AMCC is associated with mortality within 1 year after TAVR and substantially improves individual risk classification when added to a model consisting of STS score and AVC mass only.Supplemental material is available for this article.© RSNA, 2019See also the commentary by Brown and Leipsic in this issue.

4.
Eur Radiol ; 28(1): 143-150, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28695359

RESUMO

OBJECTIVE: To assess the performance of hybrid (HIR) and model-based iterative reconstruction (MIR) in patients with urolithiasis at reduced-dose computed tomography (CT). METHODS: Twenty patients scheduled for unenhanced abdominal CT for follow-up of urolithiasis were prospectively included. Routine dose acquisition was followed by three low-dose acquisitions at 40%, 60% and 80% reduced doses. All images were reconstructed with filtered back projection (FBP), HIR and MIR. Urolithiasis detection rates, gall bladder, appendix and rectosigmoid evaluation and overall subjective image quality were evaluated by two observers. RESULTS: 74 stones were present in 17 patients. Half the stones were not detected on FBP at the lowest dose level, but this improved with MIR to a sensitivity of 100%. HIR resulted in a slight decrease in sensitivity at the lowest dose to 72%, but outperformed FBP. Evaluation of other structures with HIR at 40% and with MIR at 60% dose reductions was comparable to FBP at routine dose, but 80% dose reduction resulted in non-evaluable images. CONCLUSIONS: CT radiation dose for urolithiasis detection can be safely reduced by 40 (HIR)-60 (MIR) % without affecting assessment of urolithiasis, possible extra-urinary tract pathology or overall image quality. KEY POINTS: • Iterative reconstruction can be used to substantially lower the radiation dose. • This allows for radiation reduction without affecting sensitivity of stone detection. • Possible extra-urinary tract pathology evaluation is feasible at 40-60% reduced dose.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Urolitíase/diagnóstico por imagem , Algoritmos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Sistema Urinário/diagnóstico por imagem
5.
J Comput Assist Tomogr ; 40(2): 266-71, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26720203

RESUMO

OBJECTIVE: This study aims to evaluate whether coronary calcium scoring (CCS) is also feasible using low-radiation-dose coronary computed tomography angiography (CCTA) in combination with iterative reconstruction. METHODS: Forty-three individuals without known coronary artery disease underwent both noncontrast CCS (±1 mSv) for reference Agatston scores and low-dose CCTA (±3 mSv). Raw CCTA data were reconstructed with filtered back projection (FBP), hybrid iterative reconstruction (HIR), and model-based iterative reconstruction (MIR). Calcification volumes were derived with thresholds of >351 and >600 Hounsfield units (HU) and converted to proxy Agatston scores with linear regression analysis. RESULTS: Intraclass correlation coefficients for Agatston scores versus CCTA volumes with FBP and iterative reconstruction were excellent (ranges 0.94-0.99 and 0.96-0.99 for >351 HU and >600 HU thresholds, respectively). The >351 HU threshold resulted in higher CCTA volume scores ranging from 65.9 (15.1-347.0) for HIR to 94.8 (42.0-423.0) for MIR (P = 0.001 and <0.001, respectively). The >600 HU threshold scores ranged from 14.1 (0.0-159.3) for HIR to 28.6 (0.0-215.6) for MIR (P = 0.003 and 0.027, respectively). At >351 HU, reclassification occurred in 21 individuals (49%) for FBP and HIR and 25 individuals (58%) for MIR. Reclassifications decreased with >600 HU to 10 (HIR, 23%), 8 (FBP, 19%), and 4 (MIR, 9%). CONCLUSIONS: The CCS is feasible using iteratively reconstructed low-dose CCTA with a calcium threshold of >600 HU. Using MIR, only 9% of individuals were reclassified.


Assuntos
Calcinose/diagnóstico por imagem , Angiografia Coronária/métodos , Vasos Coronários/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Cálcio , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos
6.
J Comput Assist Tomogr ; 38(2): 185-9, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24625611

RESUMO

OBJECTIVE: The objective of this study was to evaluate coronary image quality, stenosis grade, and diagnostic confidence in patients undergoing electrocardiogram-gated thoracoabdominal multidetector computed tomographic angiography (CTA) for aortic evaluation. METHODS: Seventy-five consecutive patients underwent retrospectively electrocardiogram-gated thoracoabdominal CTA reconstructed at each 12.5% of the R wave to R wave (R-R) interval. Two observers in consensus scored the coronary arteries per segment (15-segment American Heart Association model) for image quality, stenosis grade, and stenosis-assessment confidence. RESULTS: Nondiagnostic image quality prohibited coronary evaluation in 14 patients. In the remaining patients, 2% of segments was scored absent, 24% was scored nondiagnostic, 12% was scored diagnostically limited, and 61% was scored at least acceptable. Acceptable or higher image quality was seen in 82% of the proximal and middle segments. Significant stenosis (>50%) was seen in 57% of the patients. Stenosis-severity scoring confidence was moderate to high in 79% of 673 assessable segments. CONCLUSIONS: Electrocardiogram-gated thoracoabdominal CTA allows concomitant assessment of the proximal and middle coronary arteries and may serve as a combined tool for aortic-disease workup. Aortic CTA showed significant coronary artery stenosis in 57% of the patients evaluated for aortic pathology.


Assuntos
Aorta Torácica/diagnóstico por imagem , Doenças da Aorta/diagnóstico por imagem , Técnicas de Imagem de Sincronização Cardíaca , Angiografia Coronária/métodos , Estenose Coronária/diagnóstico por imagem , Tomografia Computadorizada Multidetectores/métodos , Idoso , Meios de Contraste , Eletrocardiografia , Feminino , Humanos , Iohexol/análogos & derivados , Masculino , Pessoa de Meia-Idade , Interpretação de Imagem Radiográfica Assistida por Computador , Estudos Retrospectivos
7.
Int J Cardiovasc Imaging ; 30(1): 155-63, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24046026

RESUMO

To compare coronary plaque size and composition as well as degree of coronary artery stenosis on coronary Computed Tomography angiography (CCTA) using three levels of iterative reconstruction (IR) with standard filtered back projection (FBP). In 63 consecutive patients with a clinical indication for CCTA 55 coronary plaques were analysed. Raw data were reconstructed using standard FBP and levels 2, 4 and 6 of a commercially available IR algorithm (iDose(4)). CT attenuation and noise were measured in the aorta and two coronary arteries. Both signal-to-noise-ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. The amount of lipid, fibrous and calcified plaque components and mean cross-sectional luminal area were analysed using dedicated software. Image noise was reduced by 41.6% (p < 0.0001) and SNR and CNR in the aorta were improved by 73.4% (p < 0.0001) and 72.9% (p < 0.0001) at IR level 6, respectively. IR improved objective image quality measures more in the aorta than in the coronary arteries. Furthermore, IR had no significant effect on measurements of plaque volume and cross-sectional luminal area. The application of IR significantly improves objective image quality, and does not alter quantitative analysis of coronary plaque volume, composition and luminal area.


Assuntos
Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Estenose Coronária/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Tomografia Computadorizada Multidetectores , Placa Aterosclerótica , Interpretação de Imagem Radiográfica Assistida por Computador , Adulto , Algoritmos , Doença da Artéria Coronariana/metabolismo , Estenose Coronária/metabolismo , Vasos Coronários/química , Feminino , Fibrose , Humanos , Lipídeos/análise , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Retrospectivos , Índice de Gravidade de Doença , Razão Sinal-Ruído , Calcificação Vascular/diagnóstico por imagem
8.
Eur Radiol ; 22(10): 2103-9, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22618522

RESUMO

OBJECTIVES: To determine the influence of iterative reconstruction (IR) on quantitative computed tomography (CT) measurements of emphysema, air trapping, and airway wall and lumen dimensions, compared to filtered back-projection (FBP). METHODS: Inspiratory and expiratory chest CTs of 75 patients (37 male, 38 female; mean age 64.0 ± 5.7 years) were reconstructed using FBP and IR. CT emphysema, CT air trapping and airway dimensions of a segmental bronchus were quantified using several commonly used quantification methods. The two algorithms were compared using the concordance correlation coefficient (p (c)) and Wilcoxon signed rank test. RESULTS: Only the E/I-ratio(MLD) as a measure of CT air trapping and airway dimensions showed no significant differences between the algorithms, whereas all CT emphysema and the other CT air trapping measures were significantly different at IR when compared to FBP (P < 0.001). CONCLUSION: The evaluated IR algorithm significantly influences quantitative CT measures in the assessment of emphysema and air trapping. However, the E/I-ratio(MLD) as a measure of CT air trapping, as well as the airway measurements, is unaffected by this reconstruction method. Quantitative CT of the lungs should be performed with careful attention to the CT protocol, especially when iterative reconstruction is introduced. KEY POINTS : • New techniques in CT allow numerous quantitative measurements of lung function. • Iterative reconstruction influences quantitative CT measurements of emphysema and air trapping. • Expiratory-to-inspiratory ratio of mean lung density and airway measurements are unaffected by iterative reconstruction. • Quantitative lung-CT should be performed with careful attention to the CT protocol.


Assuntos
Processamento de Imagem Assistida por Computador , Enfisema Pulmonar/diagnóstico por imagem , Enfisema Pulmonar/fisiopatologia , Tomografia Computadorizada por Raios X , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA