Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Bases de dados
Tipo de estudo
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Bioanalysis ; 2(4): 721-31, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21083270

RESUMO

BACKGROUND: Specificity and sensitivity are essential in assays for immunogenicity assessment of biotherapeutics. Nonspecific interactions from excess therapeutic or anti-therapeutic antibody, soluble ligands (e.g., target receptor), or serum proteins associated with autoimmune conditions (e.g., rheumatoid factor) in samples can impact the detection of a true anti-therapeutic response. RESULTS: Electrochemiluminescence-based bridging assay formats could eliminate the interference due to rheumatoid factor with no pretreatment with Melon Gel™ or aggregated IgG. The interference due to soluble factors was not platform specific for the four therapeutics evaluated in this study. CONCLUSION: Melon Gel pretreatment and avidin high-bind (Meso Scale Discovery) plates can effectively reduce interference due to rheumatoid factor in ELISA- and electrochemiluminescence-based assays, respectively. Excess levels of therapeutic and anti-therapeutic antibodies in bridging assays can impact assay specificity.


Assuntos
Bioensaio/métodos , Imunidade/efeitos dos fármacos , Preparações Farmacêuticas/análise , Métodos Analíticos de Preparação de Amostras , Anticorpos/sangue , Anticorpos/imunologia , Artefatos , Humanos , Imunoensaio , Ligantes , Preparações Farmacêuticas/metabolismo , Solubilidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA